{"id":155,"date":"2018-11-19T17:58:56","date_gmt":"2018-11-19T17:58:56","guid":{"rendered":"http:\/\/www.twistidea.com\/manual\/?p=155"},"modified":"2018-11-19T17:58:56","modified_gmt":"2018-11-19T17:58:56","slug":"honeywell-at140a1000-40va-120v-transformer-60-hz","status":"publish","type":"post","link":"https:\/\/www.twistidea.com\/manual\/honeywell-at140a1000-40va-120v-transformer-60-hz\/","title":{"rendered":"Honeywell AT140A1000 40Va, 120V Transformer &#8211; 60 Hz."},"content":{"rendered":"<p>Download PDF Manual:<\/p>\n<p><a href=\"http:\/\/www.twistidea.com\/manual\/wp-content\/uploads\/sites\/3\/2018\/11\/Honeywell-AT140A1000-40Va-120V-Transformer-60-Hz.pdf\">Honeywell AT140A1000 40Va, 120V Transformer &#8211; 60 Hz.pdf<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-159\" src=\"http:\/\/www.twistidea.com\/manual\/wp-content\/uploads\/sites\/3\/2018\/11\/Honeywell-AT140A1000-40Va-120V-Transformer-60-Hz.png\" alt=\"\" width=\"602\" height=\"683\" srcset=\"https:\/\/www.twistidea.com\/manual\/wp-content\/uploads\/sites\/3\/2018\/11\/Honeywell-AT140A1000-40Va-120V-Transformer-60-Hz.png 602w, https:\/\/www.twistidea.com\/manual\/wp-content\/uploads\/sites\/3\/2018\/11\/Honeywell-AT140A1000-40Va-120V-Transformer-60-Hz-264x300.png 264w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/p>\n<p><strong>Full Text of Manual:<\/strong><\/p>\n<p>Honeywell<br \/>\nAT120A,AT140A,AT150A,AT175A<br \/>\nUniversal Transformers<br \/>\nAPPLICATION<br \/>\nThese transformers are for use in 24 Vac nominal control<br \/>\ncircuits. They are typically used in heating\/cooling control<br \/>\nsystems but can be used in any application that does not<br \/>\nexceed the load ratings. They meet National Electrical<br \/>\nINS1f&#8217;ALLAiTl\u00a9N INSTRlUC1il\u00a9NS<br \/>\nCode Class 2 &#8220;not wet&#8221; and Class 3 &#8220;wet&#8221; requirements<br \/>\nand are Underwriters Laboratories (UL} Inc. listed under<br \/>\nUL 1585. They can be mounted through a 7\/8 in. knockout<br \/>\non the accessory mounting plate (included}, or with<br \/>\nthe integral mounting feet. See Table 1 for additional<br \/>\nspecifications.<br \/>\nTable 1. Model Specifications.<br \/>\nPrimary<br \/>\nI<br \/>\nInput<br \/>\nModel<br \/>\nI<br \/>\nVoltage Wiring Open<br \/>\nNumber (60Hz) Connections Circuit<br \/>\nAT120A \\ 120\/208\/ 9 in. leads 27.0<br \/>\n240<br \/>\nAT140A 120 9 in. leads 27.0<br \/>\n120\/208\/<br \/>\n240<br \/>\n120\/240<br \/>\n208\/240<br \/>\nAT150A 120\/208\/ 9 in. leads 27.5<br \/>\n240<br \/>\nAT175A 120\/208\/ 9 in. leads 27.5<br \/>\n240<br \/>\nINSTALLATION<br \/>\nWhen Installing this Product &#8230;<br \/>\n1. Read these instructions carefully. Failure to follow<br \/>\nthem could damage the product or cause a hazardous<br \/>\ncondition.<br \/>\n2. Check the ratings given in the instructions and on<br \/>\nthe product to make sure the product is suitable for<br \/>\nyour application.<br \/>\n3. Installer must be a trained, experienced service<br \/>\ntechnician.<br \/>\nSecondary<br \/>\nVoltage<br \/>\nAt Rated Output Rating at<br \/>\nPower Wiring 100 Percent Power<br \/>\nOutput connections Factor<br \/>\n24.0 Screw 20VA<br \/>\nterminals<br \/>\n24.0 Screw 40VA<br \/>\nterminals<br \/>\n24.0 Screw SOVA<br \/>\nterminals<br \/>\n24.0 Screw 75VA<br \/>\nterminals<br \/>\n4. After installation is complete, check out product<br \/>\noperation as provided in these instructions.<br \/>\n,iLCAUTION<br \/>\nElectrical Hazard.<br \/>\nCan cause electrical shock or equipment<br \/>\ndamage.<br \/>\nDisconnect power supply before beginning<br \/>\ninstallation.<\/p>\n<p>AT120A. AT140A, AT150A, AT175A UNIVERSAL TRANSFORMERS<br \/>\nMounting<br \/>\nThe transformer can be mounted in one of three ways:<br \/>\n&#8211; foot mounting.<br \/>\n&#8211; plate mounting.<br \/>\n&#8211; mounting through outlet box knockout hole.<br \/>\nFoot Mounting<br \/>\n1. Mount the transformer using screws (not supplied}<br \/>\nthrough the four 3\/16 in. x 3\/8 in. holes in the<br \/>\nmounting feet. . . .<br \/>\n2. Make line voltage primary connections w1th1n an<br \/>\napproved enclosure. See Fig. 1.<br \/>\n3. Discard the mounting plate.<br \/>\nMOUNTING<br \/>\nFOOT(2)~<br \/>\nFig. 1. Foot mounting.<br \/>\nPlate Mounting<br \/>\nMOUNTING PLATE TO lRANSFORMER<br \/>\nMount the plate to the transformer in either of two<br \/>\npositions (see Fig. 2):<br \/>\n\u2022 at clamp on primary end bell.<br \/>\n\u2022 at laminations.<br \/>\n69-0251-3<br \/>\nPLATE MOUNTED AT CLAMP ON PRIMARY END BELL<br \/>\nMOUITTING PLATE<br \/>\nlEADWIRES<br \/>\nFORPRIMAR.y<br \/>\nCONNECTIONS<br \/>\nSCREW<br \/>\nTERMINALS FOR<br \/>\nSECONDARY<br \/>\nCONNECTTONS<br \/>\n&#8216;- RAISEOPORTIONOF<br \/>\nLARGE CENTER KNOO&lt;OUT<br \/>\nPLATE MOUNTED AT THE LAMINATIONS<br \/>\n&amp;. MOUNTINGFEETON&#8221;A&#8221;MOOELSONLY.<br \/>\nFig. 2. Mounting plate to transformer in either<br \/>\nof two positions.<br \/>\nMOUNTING PLATE AT CLAMP ON PRIMARY END BELL<br \/>\n1 Turn the screw on the clamp almost all the way out.<br \/>\n2. Hold the mounting plate with the keyhole slots up<br \/>\n. and the raised portion of the large center knockout<br \/>\nthread the primary leadwires<br \/>\n. through the round center hole in the plate.<br \/>\nFit the clamp and screw through the round hole. !: While holding the plate in place<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Download PDF Manual: Honeywell AT140A1000 40Va, 120V Transformer &#8211; 60 Hz.pdf Full Text of Manual: Honeywell AT120A,AT140A,AT150A,AT175A Universal Transformers APPLICATION These transformers are for use in 24 Vac nominal control circuits. They are typically used in heating\/cooling control systems but can be used in any application that does not exceed the load ratings. They meet &hellip; <a href=\"https:\/\/www.twistidea.com\/manual\/honeywell-at140a1000-40va-120v-transformer-60-hz\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Honeywell AT140A1000 40Va, 120V Transformer &#8211; 60 Hz.&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[],"class_list":["post-155","post","type-post","status-publish","format-standard","hentry","category-user-manual"],"_links":{"self":[{"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/posts\/155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/comments?post=155"}],"version-history":[{"count":1,"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/posts\/155\/revisions"}],"predecessor-version":[{"id":160,"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/posts\/155\/revisions\/160"}],"wp:attachment":[{"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/media?parent=155"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/categories?post=155"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.twistidea.com\/manual\/wp-json\/wp\/v2\/tags?post=155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}