Full Text Searchable PDF User Manual
DCN Next Generation 4.41
Release Notes
en Release Notes
DCN Next Generation Release Notes
en | 2
Bosch Security Systems| 2014-10-31
DCN Next Generation Release 4.41
Table of Contents
1
This release Contains
........................................................................................................ 2
2
Improved and added Functionality
.................................................................................. 2
3
Release Compatibility Restrictions
.................................................................................. 6
4
Software, Firmware & FPGA versions
............................................................................. 7
5
Additional Information to the DCN Manuals and Help Files
.......................................... 9
6
Trouble Shootings and known issues
............................................................................. 9
1
This release Contains
The following versions are part of this release:
Product
version
DCN-SW
4.41
DCN-SWSMV
4.40
DCN-SWSACC
4.40
DCN-SWWA
1.11
DCN-DLT (CCU2)
4.41
DCN-CCU2
4.41
HdCameraControl
4.40
DCN-DLT (CCU, NCO)
3.10
DCN-CCU
3.10
2
Improved and added Functionality
Release Release
Date
Release Comments
4.41
2014-11-02
New functionality and improvements
•
Improved DCN wireless firmware to make it more robust in
environments with a lot of WiFi communication
•
Unresponsive microphone control in Operator application due
to network disconnections
•
Added DCN-SW icons to DVD
DCN Next Generation Release Notes
en | 3
Bosch Security Systems| 2014-10-31
Release Release
Date
Release Comments
4.40
2014-07-30
New functionality and improvements
•
Added Notebooker configuration to the API and
DcnApiDemonstrator
•
Added AGC on/off to audio outputs of Audio Expander in
Individual Channels mode
•
DCN-CCU2 supports Omneo Media Interface to interface with
DCN multimedia
•
Added Mongolian to Concentus display
•
ID cards can be programmed via API with and without CRC
•
Insert and remove of ID card can be executed via API to enable
interfacing with third party identification system
•
Windows 8.1 support for DCN-SW
•
Windows 8.1 support for DCN-SWSMV
•
Windows 8.1 support for DCN-SWSACC
•
Windows 8.1 support for HdCameraControl
•
Added Crystal Reports installer to Tools directory. This needs
to be installed to print the voting reports from DCN-SWSMV.
Note
•
Windows Vista is no longer supported for DCN-SW, DCN-
SWSMV, DCN-SWSACC, HdCameraControl
4.30
2014-01-31
New functionality and improvements
•
DcnHdCameraControl added second video switcher Kramer
MV-6
•
DcnHdCameraControl made screen line configurable
•
DcnHdCameraControl added camera transition time
•
added create groups, rename meetings, rename sessions,
request list via API (DCN-SWAPI) including demonstrator
application with source code.
Fixes
•
Increased the vote description from 50 to 130 characters.
•
Indivual voting results not translated.
4.21
2013-09-30
Fixes
•
Multi channel and multi lingual DCN-SWWA (version 1.1.1)
added.
•
Russian helpfile missing in DCN-SW.
•
Previous DCN-SW version cannot be upgraded because
database of previous DCN-SW version cannot be upgraded.
DCN Next Generation Release Notes
en | 4
Bosch Security Systems| 2014-10-31
Release Release
Date
Release Comments
4.20
2013-07-15
New functionality and improvements
•
DCN-SW added Opinion Poll and Audience Response
(requires DCN-SWMV multi voting license)
•
Select, Summon, Start, Hold, Stop of votings via API (DCN-
SWAPI) including demonstrator application with source code.
•
DCN-SW copy vote and copy session added to Configuration
Application and API to improve usability
•
Master Volume Control and Chairman Priority added to Control
API.
•
Added Vietnamese and Indonesian language to DCN-SW,
DCN-SWSMV and DCN-SWSACC
•
Added get and set System ID for slave CCU’s to Open
Interface
•
Response list length increased from 5 to max 25 and made
configurable on CCU and via DCN-SW
•
Number of Open Microphones (NOM) increased from 4 to 25.
•
Number of seats which can be added to the Notebook
increased from 15 to 25.
•
Increased Operator Application target size
•
Added group speech timers to DCN-SWSMD (and
DcnSmdDemonstrator application)
•
Added show last minute of speech by blinking microphone LED
•
Added a new audio routing option to the CCU: Insert no AGC.
Fixes
•
DCN-SW added Czech, language to the installer.
•
Show OI connection on CCU
•
Solved inconsistencies in showing voting results
•
Solved SMD error regarding loss of speaker information when
chairman speaks and ID cards and speechtimers are used.
•
Voting control on desktop does not show graphs for group
results
DCN Next Generation Release Notes
en | 5
Bosch Security Systems| 2014-10-31
Release Release
Date
Release Comments
4.10
2013-04-17
New functionality and improvements
•
Start/Stop Meeting and Session and Microphone Management
control via API (DCN-SWAPI) including demonstrator
application with source code.
•
Control of the IDesk outgoing channel using DCN Operator
Application (requires DCN-SWSI license).
•
DCN-SW added Voice Activated Microphone Logging to
identify which microphone is active in VOICE mode (requires
DCN-SWVAML license). Can be used in combination with
camera control to see who is speaking is voice mode.
•
DCN-SW font colour below icons on layout can be changed.
•
DCN-SW Meeting can be copied (including all settings) using
Configuration Application and API.
•
Demonstrator application including source code for DCN-
SWSMD XML streaming meeting data.
•
HD Camera Control via DCN-SWSMD streaming meeting data.
•
DCN-SW added Czech language to the GUI. Czech language
has to be copied manually, please refer to the Tools\Language\
directory.
•
Extended the explanation about the TCP connection in Open
Interface description.
•
DCN-SWWA Webcast application added. Only English User
interface. Only one audio-channel/language.
Fixes
•
DCN-SWSMD information regarding microphone on off.
•
DCN-SWSMD information empty when session name and
description are identical.
•
Stopping an Operator-control session does not clear request
list.
•
DCN-MR wave form and audio sometimes not in sync.
•
DCN-SW not all GUI texts fit.
•
DCN-SWSMV Reset microphone sensitivity ALL
MICROPHONES.
•
DCN-CCU2 can cause acoustic feedback when powered up in
Insertion mode.
•
DCN-SW added Slovenian language to GUI. Made Japanese
helpfile part of the installer. Added Thai, Polish and Finnish
language to the installer.
•
DCN-SWSMD Participant is made absent when Chairman
speaks in Operator with response mode.
•
Quorum shows strange behaviour with ID-cards and Secret
voting.
•
Performance and stability improvements on DCN SW Server
and Operator Control
•
Delegate names are not shown in speakerlist when using
access control for voting only.
4.03
2012-07-15
Fixes
•
DCN-SW Operator Application can cause a fault pop up upon
user login and start session.
•
DCN-SW Configurator Application can cause a fault pop up
when a document will be inserted with a file name that is too
long.
•
DCN-SW Printing Application will not start up in Spanish,
Catalan, Portuguese and Polish.
4.02
2012-04-16
Fixes
•
Inserting or withdrawing of ID-cards could lead to fault pop up.
DCN Next Generation Release Notes
en | 6
Bosch Security Systems| 2014-10-31
Release Release
Date
Release Comments
4.01
2012-03-01
Fixes
•
Auto-relay is always activated when the B-output channel is
selected (Using DCN-SW with DCN-SWSI).
4.00
2011-12-02
•
DCN-CCU2 replaces DCN-CCU, DCN-WCCU and DCN-NCO
•
DCN-CCUB2 replaces DCN-CCUB
3.10
2011-07-26
New functionality and improvements
•
Simultaneous Interpretation DCN-SWSI added
•
Usher call and speak slowly requests support DCN-SWMD
•
DCN-SW GUI languages: de, ca, en, es, fr, hu, it, jp, ko, lt, nl,
no, pt, ru, sv, zh-chs
•
DCN-SW help files languages: de, en, es, fr, it, nl, zh-chs
•
Seat assignment and seat definition improved
•
DCN-SWSACC indicates when DCN-SWSACC licenses is
missing.
3
Release Compatibility Restrictions
The following versions are compatible with this release:
Product
Hw
FPGA
SW
FW
DCN-CCU2
na
na
4.4x
DCN-CCU
1.07
--
3.1x
DCN-CCU in multi CCU mode
>=5.0
>=2.17
--
DCN-NCO
LBB 4120/00 Interpreter desk
>=1.2
--
--
Toggle in DCN-IDESK
>=1.40.xxxx
The following applications are compatible with this release:
Product
Hw
FPGA
SW
FW
DCN-SW
4.00.3959
4.40
4.40
DCN-SWSMV
4.40
DCN-SWSACC
4.40
DCN-MR
2.0
Download and License Tool
4.40
DCN-SWWA
1.10
HdCameraControl
4.40
Optical devices
5.02
DCN-SWSMV: exporting voting results to PowerPoint is only supported for PowerPoint 2003.
DCN-SWWA requires DCN-CCU(B)2.
Wireless Units:
New firmware is developed for the DCN Wireless units to operate with the DCN-CCU2 (e.g.
encryption functionality). This firmware can be uploaded using the Download and License Tool
(DLT) and the Upgrade Toolkit (DCN-UPTK). This firmware works with DCN-CCU2 and DCN-
WCCU.
Products with the following hardware version have already this firmware installed.
Product
Hw
DCN-WD-D
02/04
DCN-WDD-D
02/04
DCN-WDV-D
02/04
DCN-WDCS-D
02/05
DCN-WDDCS-D
02/05
DCN-WDVCS-D
02/05
DCN Next Generation Release Notes
en | 7
Bosch Security Systems| 2014-10-31
4
Software, Firmware & FPGA versions
The table below provides a versions overview of parts which cannot be downloaded using the
Download and License Tool or the DCN-UPTK Wireless upgrade Tool kit.
Please contact your local Bosch representative how to update these parts.
The HW column indicates if the Hardware Version of the product is supported for the listed parts.
For product which cannot show the FPGA version, the HW version belonging to the FPGA version
is shown between brackets after the FPGA version.
DCN-CCU & DCN-WCCU
FPGA
HW
Fixes
2.23
≥ 4.0 Slow reacting Multi CCU system
2.22
≥ 4.0 Noise or no audio on delegate loudspeaker
2.20
≥ 4.0 Unstable system after start-up due to optical network disturbances
2.19
≥ 4.0 Noise on delegate loudspeaker
2.18
≥ 4.0 Unexpected beeps on delegate loudspeaker fixed
DCN-CCUB
FPGA
HW
Fixes
1.22
≥ 1.0 Noise or no audio on delegate loudspeaker
1.09
≥ 1.0 Noise on delegate loudspeaker
1.08
≥ 1.0 Unexpected beeps on delegate loudspeaker
DCN-CONxx range
FPGA
HW
Fixes / Additions
1.17 (hw1.12)
≥ 1.0 Address might be lost after system restart
1.14 (hw1.10)
≥ 1.0 11Khz noise
SW
1.10.xxxx (hw1.13) ≥ 1.0 CRC check added for ID-cards
DCN-DDI
FPGA
HW
Fixes / Additions
2.2 (hw02.01)
≥ 1.0 11Khz noise
2.0 (hw02.00)
≥ 1.0 CRC check added for ID-cards
DCN-DIS range
FPGA
HW
Problem fixed
1.20 (hw02.06)
≥ 1.0 11Khz noise
1.18 (hw02.03)
≥ 1.0 Disturbed audio on headphones for channels > 28
Address might be lost after system restart
1.15
≥ 1.0 Channel auto increment equal to DCN-CON
1.13 (hw02.02)
≥ 1.0 Audio distorted on headphones
DCN-FCS
FPGA
HW
Fixes
2.7 (hw02.02)
≥ 2.0 11Khz noise
DCN-IDESK
FPGA
HW
Fixes / Additions
2.1
≥ 2.0 11Khz noise
SW
1.41.xxxx
≥ 1.0 loudspeaker symbol might be shown in front of the quality indicator
after leaving the Idesk’s installation menu
1.40.xxxx
≥ 1.0 B Toggle added
INT-TX Range
DCN Next Generation Release Notes
en | 8
Bosch Security Systems| 2014-10-31
FPGA
HW
Fixes / Additions
02.03
≥ 1.0 The display might show unexpected characters
02.02
≥ 1.0 Improved stability when used in combination with the DCN system
02.01
≥ 1.0 Improved stability when used in combination with the DCN system
02.00
≥ 1.0 Initial version
DCN Next Generation Release Notes
en | 9
Bosch Security Systems| 2014-10-31
5
Additional Information to the DCN Manuals and Help
Files
Reference
What
DCN-SW
When installing DCN-SW on a Windows 7 PC you might get the following
notification:
This is because within the time installer checks for framework, SQLServer
installation starts which prompt for the framework installation.
Please press OK, after this the framework will be installed from the DCN-SW
installer and DCN-SW installation will install successful.
Wireless
Discussion
Units
Wireless Discussion Units which are produced before 2012 need to be upgraded
using the DCN-UPTK and DLT (4.xx) in order to operate with a DCN-CCU2.
DCN-
SWSMV
Showing voting results in PowerPoint
In case PowerPoint is used to show the voting result, it might happen that
PowerPoint starts and overlaps the user interface of DCN-SWSMV completely.
Use the Windows task bar to select DCN-SWSMV again.
DCN-
SWSMV
Printing voting results
To print voting results, Crystal Reports needs to be installed. It is located in the
Tools directory of the DVD.
6
Trouble Shootings and known issues
This trouble shootings and known issues are in addition to chapter 2 and to the trouble shooting
chapter in the user manuals.
Product/function
Problem
Solution
DCN-SW
Configuration
Application
In rare occasions it
can happen that the
application closes
unintended.
Restart the DCN-SW Configuration Application.
DCN-SW rinting
individual voting
results manually
Individual voting
results are not printed
when printed
manually via Bosch
DCN SW Print
Application.
Change the voting template accordingly:
1.
Check the “Automatic print after stop of the
voting” checkbox.
2.
Change the settings to Total, groups and
individuals.
3.
Uncheck “Automatic print after stop of the
voting” checkbox.
DCN-SW multi PC
Client cannot connect
with Server when
multiple network
adapters are available
Configure the adapter settings in such a way that the
network adapter which is used for DCN NG is the
highest in the list of connections in Adapters and
Bindings
DCN-SW
Delegate both in
Request to speak as
Request to respond
list.
If a delegate is both in the Request to Respond as in
the Request to Speak list and you want to shift the
Request to Speak to Speaking, first cancel the
Request to Respond.
DCN Next Generation Release Notes
en | 10
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-SW
On 64-bit operating
systems, it might
difficult to find
previous SQL-server
during DCN-SW
installation, when
initial SQL-installation
was not default.
During installation of DCN-SW the installation process
might not be able to find the previous SQL-server, in
case during initial installation another name for the
SQL-server was created, instead of using the default
name. Therefore it is recommended to use the default
name and folder during initial SQL-installation. If a
SQL-server with a non-default name needs to be
found, the correct name should be entered manually
in the applicable box during DCN-SW installation.
DCN-SW
System overview
does not show all
connected devices
when system is still
powering up.
Wait until DCN-system is powered up completely and
then check the connected devices via DCN-SW
configuration application VIEW \ System Overview.
DCN-SW
DCN-SW Master
Volume is different
from CCU volume
control
When the Master Volume of the CCU has been
changed while DCN-SW was disconnected, the DCN-
SW Master Volume will not reflect the CCU-setting.
Changing the DCN-SW volume setting, will make
them identical again.
DCN-SW
Downgrade to
versions <3.10 not
possible.
Manually uninstall SWL server 2008.
Note that the DCN-SW database (the database
contains all settings like seats, meetings, synoptic
layouts, etc.) will always be removed during a
downgrade.
DCN-SW
Unexpected
behaviour or no
reaction of DCN-SW.
Due to Windows Automatic Updates some critical
components like SQL Server Express might be
temporarily not available for DCN-SW.
Do not set Automatic Updates to Automatic or restart
your system after the Automatic updates have been
installed.
DCN-SW
Generates errors after
Windows Stand by..
Disable Stand by functionality in the Windows
operating system.
DCN-SWPV
Secret mode does not
work in ad-hoc voting
Update to version 2.80 or higher
DCN-SWPV
Voting attention tone
cannot be changed
during a running
meeting.
The voting attention tone can be changed in the
voting template but becomes effective after a vote has
been selected or started.
DCN-SW setup
repair
Error code 2869 or
Fatal error during
installation.
Remove DCN-SW with DCN-SW setup and make a
new installation. Settings are stored in the SQL-
database and can be re-used in the new installation.
DCN-SWSMV
Error notification upon
closing DCN-SWSMV
directly after opening
it.
Please wait at least 10 seconds to close DCN-
SWSMV after opening it.
DCN-SWSMV help
file
When opening help
file you get an error.
Just close the error notification.
DCN-SWSMV
DCN-SWSMV will not
start
Voting legends cannot be changed into “Not Voted”.
Remove “BCPCSettings.xml” which can be found:
For XP:
“…\Documents and Settings\All Users\Application
Data\Bosch\DCN Synoptic Microphone and Voting
Software\x.xx”
For Vista:
“…\Programdata\Bosch\DCN Synoptic Microphone
and Voting Software\x.xx”
DCN Next Generation Release Notes
en | 11
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-SWWA
Does not work with
DCN-SW
DCN-SWWA 1.1.1 requires DCN-SW 4.2x or later
DCN-SWWA 1.0.1 requires DCN-SW 4.1x
DCN-SWWA
Webcast will stop
after 12 hours.
Maximum webcast length of a webcast is 12 hours. It
will stop automatically.
DCN-SWWA
No audio on SDI input
box
With setup, please note if there is no audio, resetting
the Audio to SDI box most of the time will solve the
problem.
DCN-SWWA
Opinion Poll and
Multiple Choice
information from
DCN-SWSMD is not
supported.
none
DCN-SWWAEC
Slave languages not
added after using
Refresh function.
Refresh webcast will only effect PowerPoint slides.
Load webcast will add the languages
DCN-SWWAEC
Webcast will not start
on slave PC’s.
Close the publisher on slave PC’s before starting a
new webcast.
Not all text is
shown on
Webcasting player
For security reasons,
all text between the
signs ‘<’and ‘>’ is
removed and currently
not shown on the
webcasting player
website.
Do not use the “<” and “>” characters in DCN-SW
(e.g. meeting information, session information, voting
information, delegate names) or Webcast Planner
Website.
Wireless system in
combination with
Integrus
No audio on DCN
wireless units when
powering up DCN-
CCU2 and Integrus
transmitter
simultaneous.
First power up the DCN-CCU2. After it is powered up,
power up the Integrus transmitter.
Not able to
download DCN-
CCU2 firmware
DCN-DLT is not able
to download the
firmware of the CCU
Check if the DCN-SW server is not running:
1.
Exit the DCN-DLT program
2.
Check if the DCN-CCU2 does not report PC
on it’s display. If it does Stop the DCN-SW
server via Start\ <Search programs and files>
SERVICES. Services (local). And check if PC
disappears.
3.
Start DCN-DLT (PC will now re-appear in the
CCU2 screen, but that is correct) and start
the download.
If the download still fails, do the following:
1.
Power off and open the DCN-CCU2
2.
Set switch 8 of S600 to ON and power on the
CCU.
3.
Download the CCU using the DCN-DLT.
4.
After a succesfull download, power off the
CCU, set switch 8 of S600 to OFF again and
power on the CCU.
HD Conference
Dome
The HD Conference
Dome will show an
incorrect name &
picture combination if
a new pre-position is
asked before it
reaches it’s pre-
position.
Do not activate another microphone until the HD
Conference Dome has reached it’s pre-position.
DCN-UPTK
The type of the unit
connected to the
UPTK is not valid.
This notification can occur when the DCN-UPTK unit
is used extensively. Please replace the connection
cable.
DCN Next Generation Release Notes
en | 12
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-CCU(B)2
Error relays activated
upon system reset or
firmware download.
During a firmware download or system reset, the
system is not in normal operation and thus the error
relays can be active.
DCN-CONFF and
DCN-CONCM
DNPV answers in
voting are not visible
in the Concentus
screen when a voting
timer is activated.
Use a hall display or disable the voting timer.
DCN-SWSACC
and Allegiant
Double screenlines
are still visible on
audience screens
after switching to
single screenlines.
Restart the Allegiant.
DCN-SWSACC
Upload does not work
anymore.
Restart the DCN-CCU or DCN-NCO.
DCN-MR
DCN-MR does not
connect to DCN-SW
when installed on
another PC
1.
Open the Meeting Recorder.ini file with notepad
it is located here: C:\Users\[USER
NAME]\AppData\Roaming\Meeting Recorder
if the user name is administrator, the path will
be: C:\Users\
Administrator\AppData\Roaming\Meeting
Recorder
2.
Find the variable NCO Ip=x.x.x.x (where x.x.x.x is
the IP address of DCN SW server) and below that
line;
Create a line DCO Ip=x.x.x.x (where x.x.x.x is the
IP address of the DCN SW server)
NCO Port=20000
NCO Ip=10.120.22.230
DCO Ip=10.120.22.230
CCU Ip=192.168.1.1
3.
Save the Meeting Recorder.ini file
DCN-MR
Windows audio
playback is lost after
installation DCN-MR
1.3. in windows XP.
Replace files msacm32.drv, msadp32.acm and
imaadp32.acm in the windows system32 folder.
Multi CCU systems System reaction is
(very) slow after
system startup.
The system might become (very) slow when in a multi
CCU system only the NCO is switched off and the
rest of the system stays switched on.
To prevent this problem:
Shutdown all optical devices in the Multi-CCU system.
DCN Next Generation Release Notes
en | 13
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-NCO
DCN-NCO cannot be
downgraded or
upgraded.
A known issue is that DCN-NCO cannot be
downgraded from SW 2.70.
Workaround
1)
Install the Download and License Tool of the
version you want to use to downgrade or upgrade
to.
2)
Open Notepad and paste the text below into
Notepad
user target password
cd /rfa
dele PDSDATA1.PDS
dele PDSDATA2.PDS
bin
hash
cd /rfa/drv
put mmu_3.bit
put mif_3.bit
cd /bim
put dune.bim
bye
3)
Save the file in Notepad to C:\Program
Files\Bosch\Digital Congress Network\Download
and License Tool\Files with name dcn-nco.txt
4)
Switch off the NCO and set dipswitch 1 of S3 to
on, set all other switches to off
5)
Switch on the NCO
6)
Open a command prompt (start -> run -> cmd)
and change to the following folder: C:\Program
Files\Bosch\Digital Congress Network\Download
and License Tool\Files
7)
Download the NCO with the next command line
FTP with the command:
ftp -n -s:dcn-nco.txt x.x.x.x
Where x.x.x.x is the IP-address of the NCO
8)
Switch off the NCO and set the dipswitches all to
off
9)
Switch on the NCO
10)
Start the Download and License Tool and start a
NCO download.
DCN-CCU DCN-
NCO
Local floor muted after
download of NCO or
CCU
Switch off and on the CCU or NCO
DCN-NCO
DCN-CCU,
INT-TX04/08/16/32
Unexpected behavior
when adding powered
system units to the
optical ring
In case system units are added to the optical ring
when the system is powered on, unexpected behavior
can occur. Only connect units to the optical network
when all units are powered off.
DCN NCO
DCN-CCU
INT-TX04/08/16/32
Audio disruption when
switching on a
transmitter
Select the option “enabled” in menu 4b (network
mode).
DCN NCO
DCN-CCU
INT-TX04/08/16/32
Audio disruption when
one of the CCUs is in
the mode
“--“
Change the slave id “--" to a number. (refer to menu
7I Multi Mode).
INT-TX04/0816/32 The transmitter
displays the message
“No Network”
Connect a powered DCN Next Generation or DCN
wireless system to the transmitter or select the option
“standalone” in menu 4b (network mode)
DCN Next Generation Release Notes
en | 14
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
INT-RX04/08/32
Charging indicator on
the receiver is blinking
Check whether the receiver is still working correctly. If
this is the case: the battery pack is fully charged and
can be recharged after using it a while.
If this is not the case: follow the instructions as given
in the troubleshooting table.
DCN-CCU
DCN-CCU shows
“Multi” while acting in
“Single”
When changing from “single” to “multi” mode, the
DCN-CCU can remain working in “single” mode.
If this is the case follow next procedure:
1.
Select “multi” on all connected CCUs
2.
Switch off all CCUs.
3.
Reset to defaults the NCO.
4.
Switch on all CCUs.
DCN-CCU
Audio disruption
during powering
up/down a CCU in a
Multi CCU system
During powering up/down a CCU in a Multi CCU
system the audio on the delegate units, connected to
the remaining CCU’s, is shortly disrupted for 1 to 2
seconds.
DCN-CCU
Loss of settings after
reboot of NCO in a
Multi CCU system
In case the Network Controller (NCO) in a Multi CCU
system is rebooted, the settings and configurations
changed during the past 30 seconds can be lost.
When configuring interpreter desks wait minimum 30
seconds before reboot the NCO.
LBB 4402/00
LBB 4404/00
PRS-4DEX4
Input routing does not
work after download
of optical devices
Change all inputs to CH00 and then to the required
channel.
INT-TX
Transmitter does not
work after updating
firmware
Update FPGA to version 2.03 or higher
Alternative solution:
Update firmware of the INT-TX to version 2.80
DCN-IDENC
DCN-IDENC ID card
encoder in not
recognized in DCN-
SW.
If other card readers/encoders are present or
connected to the PC please disable them.
Internal readers/encoders can be disabled in the
BIOS or in the Windows Device Manager.
CNConfig
Error during
installation “…verify
that you have access
to the directory.”
Ensure that you have the required administrator
rights. Restart installation.