Full Text Searchable PDF User Manual
• Outdoor Units • R-410A • RYN-E3V1B
1
1
• Split Sky Air • Outdoor Units
1
1
Features
Ou
td
oo
r
Un
i
Sp
li
t
Sk
y
A
RY
N-
E3
V1
B
R-
41
0a
•
Outdoor units for pair application
•
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
•
Outdoor units are fitted with a swing compressor, renowned for its low
noise and high energy efficiency
3
1
2
• Split Sky Air • Outdoor Units
2
• Outdoor Units • R-410A • RYN-E3V1B
2
Specifications
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
RYN50E3V1B
RYN60E3V1B
For
combination
indoor units +
outdoor units
Indoor Units
FTYN50EV1B
FTYN60EV1B
Cooling
capacity
Standard
kW
5.0
6.0
Heating
capacity
Standard
kW
5.8
7.0
Nominal input
Cooling
Standard kW
1.55
1.99
Heating
Standard kW
1.60
2.04
For
combination
indoor units +
outdoor units
EER
Nominal
3.23
3.02
COP
Nominal
3.63
3.43
Energy
Labeling
Directive
Cooling
A
B
Heating
A
B
Annual energy consumption kWh
775
995
Indoor Units
FTYN50FV1B
FTYN60FV1B
Cooling
capacity
Standard
kW
5.0
6.0
Heating
capacity
Standard
kW
5.8
7.0
Nominal input
Cooling
Standard kW
1.55
1.99
Heating
Standard kW
1.60
2.04
For
combination
indoor units +
outdoor units
EER
Nominal
3.23
3.02
COP
Nominal
3.63
3.43
Energy
Labeling
Directive
Cooling
A
B
Heating
A
B
Annual energy consumption kWh
775
995
2-2 TECHNICAL SPECIFICATIONS
RYN50E3V1B
RYN60E3V1B
Casing
Colour
Ivory White
Dimensions
Unit
Height
mm
735
735
Width
mm
825
825
Depth
mm
300
300
Packing
Height
mm
797
797
Width
mm
960
960
Depth
mm
390
390
Weight
Unit
kg
48
48
Packed Unit
kg
53
53
Heat
Exchanger
Dimensions
Length
mm
845
845
Nr of Rows
2
2
Fin Pitch
mm
1.80
1.80
Nr of Stages
32
32
Tube type
Hi-Xa(8)
Fin
Type
Waffle fin
Treatment
Anti-corrosion treatment (PE)
Fan
Type
Propeller
Quantity
1
1
Air Flow Rate
(nominal at
230V)
Cooling
m³/min
48.9
50.9
Heating
m³/min
45.0
46.3
Motor
Quantity
1
1
Model
KFD-380-50-8A
Motor
Speed
(nominal)
Cooling
rpm
780
810
Heating
rpm
720
740
Fan
Motor
Output
W
53
53
• Outdoor Units • R-410A • RYN-E3V1B
1
2
• Split Sky Air • Outdoor Units
3
2
Specifications
Compressor
Quantity
1
1
Motor
Model
2YC36BXD#A
Type
Hermetically sealed swing compressor
Motor
Output
W
1100
1100
Operation
Range
Cooling
Min
°
CDB
-10.0
-10.0
Max
°
CDB
46.0
46.0
Heating
Min
°
CWB
-15
-15
Max
°
CWB
18
18
Sound Level
(nominal)
Cooling
Sound
Power
dBA
61.0
63.0
Sound
Pressure
dBA
47.0
49.0
Heating
Sound
Pressure
dBA
48.0
49.0
Refrigerant
Type
R-410A
Charge
kg
1.5
1.5
Refrigerant Oil Type
FVC50K
Charged Volume
l
0.65
065
Piping
connections
Liquid (OD)
Diameter
(OD)
mm
6.35
6.35
Gas
Diameter
(OD)
mm
12.7
12.7
Drain
Diameter
(OD)
mm
18
18
Piping Length
Maximum m
30
30
Additional Refrigerant
Charge
kg/m
0.02/>10m
Max. internunit level
difference
m
20.0
20.0
Heat Insulation
Both liquid and gas pipes
Standard
Accessories
Item
Drain plug
Quantity
1
1
Item
Installation manual
Quantity
1
1
Notes
Nominal cooling capacities are based on : indoor temperature : 270CDB, 190CWB, outdoor temperature : 350CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 200CDB, outdoor temperature : 70CDB, 60CWB,
equivalent refrigerant piping : 7.5m, level difference : 0m
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer to sound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-3 ELECTRICAL SPECIFICATIONS
RYN50E3V1B
RYN60E3V1B
Power Supply
Name
V1
Phase
1
1
Frequency
Hz
50
50
Voltage
V
220-240
Voltage range
Minimum V
-10%
Maximum V
+10%
Current
Nominal
running current
(RLA)
Cooling
(A)
A
6.75
8.62
Heating
(A)
A
6.94
8.80
Starting current (cooling/
heating)
A
7.1
9.0
Z-max
List
No requirements
2-2 TECHNICAL SPECIFICATIONS
RYN50E3V1B
RYN60E3V1B
3
1
2
• Split Sky Air • Outdoor Units
4
• Outdoor Units • R-410A • RYN-E3V1B
2
Specifications
Wiring
connections
For Power
Supply
Quantity
3
3
For connection
with indoor
Quantity
4
4
Remark
Including earth wiring
Power Supply Intake
Outdoor unit only
2-3 ELECTRICAL SPECIFICATIONS
RYN50E3V1B
RYN60E3V1B
• Outdoor Units • R-410A • RYN-E3V1B
1
3
• Split Sky Air • Outdoor Units
5
3
Features
3
1
4
• Split Sky Air • Outdoor Units
6
• Outdoor Units • R-410A • RYN-E3V1B
4
Capacity tables
4 - 1 Cooling/Heating capacity tables
FTYN50F+RYN50E
Cooling
50Hz 220-240V
AFR
14.7
BF
0.28
Indoor
Outdoor temperature (°CDB)
EWB
EDB
20
25
30
32
35
40
(°C)
(°C)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
Heating
50Hz 220-240V
AFR
16.1
Indoor
Outdoor temperature (°CWB)
EDB
-10
-5
0
6
10
(°C)
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
3D051923A
SYMBOLS
AFR:
Air flow rate
(m
3
/min)
BF:
Bypass factor
EWB:
Entering wet bulb temp.
(°C)
EDB:
Entering dry bulb temp.
(°C)
TC:
Total capacity
(kW)
SHC:
Sensible heating capacity
(kW)
PI:
Power input
(kW)
NOTES
1
Ratings shown are net capacities which include a deduction for
indoor fan motor heat
2
shows nominal (rated) capacities and power input.
3
TC, PI and SHC must be calculated by interpolation using the figures
in the above tables. (Figures out of the tables should not be used for
calculation.)
4
About SHC which are not mentioned on the table, please calculate
them with around values in direct proportion.
5
Capacities are based on following conditions:
Corresponding refrigerant piping length:
7.5 m
Level difference:
0 m
6
Air flow rate (AFR) and Bypass factor (BF) are taburated above.
• Outdoor Units • R-410A • RYN-E3V1B
1
4
• Split Sky Air • Outdoor Units
7
4
Capacity tables
4 - 1 Cooling/Heating capacity tables
FTYN50FV1B+RYN50E3V1B
Cooling
50Hz 220-240V
AFR
14.7
BF
0.28
Indoor
Outdoor temperature (°CDB)
EWB
EDB
20
25
30
32
35
40
(°C)
(°C)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
Heating
50Hz 220-240V
AFR
16.1
Indoor
Outdoor temperature (°CWB)
EDB
-10
-5
0
6
10
(°C)
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
3D051923A
SYMBOLS
AFR:
Air flow rate
(m
3
/min)
BF:
Bypass factor
EWB:
Entering wet bulb temp.
(°C)
EDB:
Entering dry bulb temp.
(°C)
TC:
Total capacity
(kW)
SHC:
Sensible heating capacity
(kW)
PI:
Power input
(kW)
NOTES
1
Ratings shown are net capacities which include a deduction for
indoor fan motor heat
2
shows nominal (rated) capacities and power input.
3
TC, PI and SHC must be calculated by interpolation using the figures
in the above tables. (Figures out of the tables should not be used for
calculation.)
4
About SHC which are not mentioned on the table, please calculate
them with around values in direct proportion.
5
Capacities are based on following conditions:
Corresponding refrigerant piping length:
7.5 m
Level difference:
0 m
6
Air flow rate (AFR) and Bypass factor (BF) are taburated above.
3
1
4
• Split Sky Air • Outdoor Units
8
• Outdoor Units • R-410A • RYN-E3V1B
4
Capacity tables
4 - 1 Cooling/Heating capacity tables
FTYN60FV1B+RYN60E3V1B
Cooling
50Hz 220-240V
AFR
16.2
BF
0.29
Indoor
Outdoor temperature (°CDB)
EWB
EDB
20
25
30
32
35
40
(°C)
(°C)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
Heating
50Hz 220-240V
AFR
17.4
Indoor
Outdoor temperature (°CWB)
EDB
-10
-5
0
6
10
(°C)
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
3D051924A
SYMBOLS
AFR:
Air flow rate
(m
3
/min)
BF:
Bypass factor
EWB:
Entering wet bulb temp.
(°C)
EDB:
Entering dry bulb temp.
(°C)
TC:
Total capacity
(kW)
SHC:
Sensible heating capacity
(kW)
PI:
Power input
(kW)
NOTES
1
Ratings shown are net capacities which include a deduction for
indoor fan motor heat
2
shows nominal (rated) capacities and power input.
3
TC, PI and SHC must be calculated by interpolation using the figures
in the above tables. (Figures out of the tables should not be used for
calculation.)
4
About SHC which are not mentioned on the table, please calculate
them with around values in direct proportion.
5
Capacities are based on following conditions:
Corresponding refrigerant piping length:
7.5 m
Level difference:
0 m
6
Air flow rate (AFR) and Bypass factor (BF) are taburated above.
• Outdoor Units • R-410A • RYN-E3V1B
1
4
• Split Sky Air • Outdoor Units
9
4
Capacity tables
4 - 1 Cooling/Heating capacity tables
FTYN60F+RYN60E
Cooling
50Hz 220-240V
AFR
16.2
BF
0.29
Indoor
Outdoor temperature (°CDB)
EWB
EDB
20
25
30
32
35
40
(°C)
(°C)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
Heating
50Hz 220-240V
AFR
17.4
Indoor
Outdoor temperature (°CWB)
EDB
-10
-5
0
6
10
(°C)
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
3D051924A
SYMBOLS
AFR:
Air flow rate
(m
3
/min)
BF:
Bypass factor
EWB:
Entering wet bulb temp.
(°C)
EDB:
Entering dry bulb temp.
(°C)
TC:
Total capacity
(kW)
SHC:
Sensible heating capacity
(kW)
PI:
Power input
(kW)
NOTES
1
Ratings shown are net capacities which include a deduction for
indoor fan motor heat
2
shows nominal (rated) capacities and power input.
3
TC, PI and SHC must be calculated by interpolation using the figures
in the above tables. (Figures out of the tables should not be used for
calculation.)
4
About SHC which are not mentioned on the table, please calculate
them with around values in direct proportion.
5
Capacities are based on following conditions:
Corresponding refrigerant piping length:
7.5 m
Level difference:
0 m
6
Air flow rate (AFR) and Bypass factor (BF) are taburated above.
3
1
5
• Split Sky Air • Outdoor Units
10
• Outdoor Units • R-410A • RYN-E3V1B
5
Dimensional drawing & centre of gravity
5 - 1 Dimensional drawing
3D051657D
RYN50-60
E
unit (mm)
Minimum space for air passage
Wall height on air outlet side =
less than 1200
Drain outlet
(I.D.
J
15.9 hose for connection)
4 x holes for anchor bolts (M8 or
M10)
Name plate
Terminal strip with earth
terminal
Wiring inlet
Gas stop valve
(
J
12.7 CuT)
Liquid stop valve
(
J
6.4 CuT)
Service port
Outdoor air temperature
thermistor
Brand name label
In case of removing stop valve
cover
• Outdoor Units • R-410A • RYN-E3V1B
1
5
• Split Sky Air • Outdoor Units
11
5
Dimensional drawing & centre of gravity
5 - 2 Centre of gravity
4D051638C
RYN50-60E
The position of foundation bolt
3
1
6
• Split Sky Air • Outdoor Units
12
• Outdoor Units • R-410A • RYN-E3V1B
6
Piping diagram
3D051637D
RYN50-60E
Outdoor temperature thermistor
Heat exchanger
Propeller fan
Capillary tube 1
Liquid stop
valve
Field piping
Field piping
Gas stop valve with service
port
Compressor
Capillary tube 3
Refrigerant flow
Cooling
Heating
Discharge pipe
thermistor
Heat exchanger thermistor
Capillary tube 2
Capillary tube 4
Muffler with
filter
Motor operated
valve
Receiver
Filter
Outdoor unit
Muffler
Four way valve on
: heating
Muffler
• Outdoor Units • R-410A • RYN-E3V1B
1
7
• Split Sky Air • Outdoor Units
13
7
Sound data
7 - 1 Sound pressure spectrum
3D051717B
Octav
e
ban
d
soun
d
pressur
e
level
Octave band center frequency (Hz)
RYN50E (Cooling)
approximate
threshold hearing for
continuous noise
NOTES
1
Measure in anechoic room
2
Operation noise differs with operation and ambient
conditions.
3
The operation noise measuring method is in accordance with
JISC9612
Legend
50Hz, 220-240V
3D051717B
Octav
e
ban
d
soun
d
pressur
e
level
Octave band center frequency (Hz)
RYN50E (Heating)
approximate
threshold hearing
for continuous noise
NOTES
1
Measure in anechoic room
2
Operation noise differs with operation and ambient
conditions.
3
The operation noise measuring method is in accordance
with JISC9612
Legend
50Hz, 220-240V
3D051716A
Octav
e
ban
d
soun
d
pressur
e
level
Octave band center frequency (Hz)
RYN60E (Cooling)
approximate
threshold hearing for
continuous noise
NOTES
1
Measure in anechoic room
2
Operation noise differs with operation and ambient
conditions.
3
The operation noise measuring method is in accordance
with JISC9612
Legend
50Hz, 220-240V
3D0517116A
Octav
e
ban
d
soun
d
pressur
e
level
Octave band center frequency (Hz)
RYN60E (Heating)
approximate
threshold hearing
for continuous noise
NOTES
1
Measure in anechoic room
2
Operation noise differs with operation and ambient
conditions.
3
The operation noise measuring method is in accordance
with JISC9612
Legend
50Hz, 220-240V
3
1
8
• Split Sky Air • Outdoor Units
14
• Outdoor Units • R-410A • RYN-E3V1B
8
Operation range
3D028318K
RYN50-60E
Outdoo
rtemp
.(°CDB)
Pull-dow
n
period
Indoor temp. (°CWB)
Notes:
The graphs are based on the following conditions:
+
Equivalent piping length
7.5 m
+
Level difference
0 m
+
Air flow rate
high
Cooling
Heating
Indoor temp. (°CDB)
Outdoo
rtemp
.(°CWB)
Continuou
s
operation
Continuou
s
operation
(-15 °CDB)
• Outdoor Units • R-410A • RYN-E3V1B
1
8
• Split Sky Air • Outdoor Units
15
8
Operation range