Full Text Searchable PDF User Manual
THE ENVIROMAC
MOBILE AIR CLEANER
MAC1
(107.1020)
OWNER’S MANUAL
In Canada:
Enviroflex
International Inc.
17 Brownridge Road, Unit 8
Halton Hills, Ontario
L7G OC6
Phone: (905) 636-1177
Fax: (905) 636-1178
Web Site:
www.enviroflex.com
Email:
info@enviroflex.com
In USA
Enviroflex
International Inc.
1051 Clinton Street
Buffalo, New York
U.S.A 14206-2823
Phone: (716) 883-2319
Fax: (716) 892-2139
Web Site:
www.enviroflex.com
Email:
info@enviroflex.com
April 26, 2012
ABOUT THE PRODUCT
PRINCIPLE OF OPERATION
The ENVIROMAC
Portable Air Cleaner is a
media type Air Cleaner operating on a two-stage
filtration principle. After the contaminant is
picked up at the hood of the Flexible Arm it is
then drawn through the arm and through the fan
assembly and discharged to the inside part of the
high efficient washable filter. The filtered air is
discharged out the 2 doors. The 2 doors contain
charcoal, which eliminates most gases that might
be in the filtered air stream. The high efficient
washable filter collects particulate only and does
not filter gases, which is the sole purpose of the
charcoal door filters.
MAJOR COMPONENTS
The ENVIROMAC
Portable Air Cleaner is a
self-contained unit comprised of a flexible arm
(for source capture), fan and motor assembly,
high efficient washable filter, (2) carbon door
filters, complete cabinet housing and an
electrical compartment which also includes a
contactor overload.
A) HIGH EFFICIENCY HIGH EFFICIENT
WASHABLE FILTER
This filter is a high efficiency high efficient
washable filter. The suction will deteriorate at
the hood as the filter loads up with particulate.
Eventually the filter will have to be cleaned. To
commence cleaning the filter, you must remove
the door at the front of the machine which is
where the switch and nameplate are located. This
door is removed by removing the (2) plastic
knobs near the bottom of the door and then
pulling the door out on an angle so the door is
free from the (2) welded bolts. Then pull down
on the door to let it slide down from the top of
the door. You then remove the filter by lowering
the scissor jack with a ratchet. Then slide out the
cartridge filter. You then invert the filter upside
down and utilize the existing gasket on the filter
to make a seal and take an air hose with about 80
P.S.I. and blow the filter from the outside to
remove all of the particulate that is on the inside
of the filter. You can now put the cleaned filter
back into the machine and tighten the filter by
raising the scissor jack. Make sure the filter is
resting on the back of the filter cradle butted up
against the tab locators. Make sure that the top of
the filter fits inside the top plate that has a 1” lip
on it. Make sure the scissor jack is high enough
to allow an airtight seal on the top of the filter
gasket. Caution should be taken not to apply too
much pressure to the filter or you could squash
the filter if too much pressure is applied. Always
blow the outside of the filter with the gasket of
the filter either on the floor or a container to give
you a good seal so that the dirt does not escape
under the seal. Never blow from the inside as the
contaminant will blow all over the surrounding
area and will also force the very fine particulate
into the media. Once the filter is installed you
should start up the machine and feed 2 cups of
Precoat in a fine mist at the intake of the hood.
The Precoat increases the filter efficiency of the
washable filter and acts as a prefilter. Once you
complete the Precoat process you can now
commence welding.
B) CHARCOAL FILTERS
Both doors contain the charcoal filters. They
should be replaced 1 or twice a year in a normal
welding environment.
C) ELECTRICAL COMPARTMENT
The unit operates off 120 volts single phase
utilizing a 20-amp service outlet. The motor
draws about 17.5 amps under full load
conditions. There is a contactor and an overload
inside this compartment and the overload is set at
about 20% above the 17.5 amps. This will
automatically shut off power to the motor in the
event of an overload. This gives full protection to
the motor. The unit has a spring activated on/off
dual switch on the front of the panel. There are
facilities to put in an optional halogen light in the
hood of the arm. This requires a 120 Volt to 24-
volt step down transformer for this option. The
halogen light will run off of 24 volts AC.
C) CABINET
The cabinet is built of 14-gauge steel. There are
2 doors on the unit and the discharge of the clean
air is through these 2 doors.
D) BLOWER AND MOTOR SECTION
The motor is a 1.5 HP TEFC, 120/1/60, 3600
RPM. The fan is a high-pressure fan fabricated
out of 14 gauge metal.
E) ADDITIONAL EQUIPMENT FEATURES
The standard unit comes equipped with the
Snorkvac™ 10 Ft. flexible arm. The 3 articulated
joint sections could be adjusted to suit the
operator as to the ease of movement of the 4
different articulations. There is an optional 14 Ft.
Snorkvac™ flexible fume arm.
MAINTENANCE SCHEDULE
The filter should be cleaned or replaced when
there is inadequate suction at the hood. The
charcoal door filters should be replaced once or
twice a year. The arm has friction discs with
washers, which can be adjusted to suit the
operator. The unique design of the arm
minimizes any problems related to sagging, burn
holes in the hose and ease of arm movement.
This is a major problem with conventional less
expensive arms.
Thank you for purchasing your new
ENVIROMAC
Portable Air Cleaner. The air
in your work area will be much healthier to
breathe.
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
ENVIROMAC
ENVIROMAC
ENVIROMAC
ENVIROMAC
WARRANTY
WARRANTY
WARRANTY
WARRANTY
The
ENVIROMAC
ENVIROMAC
ENVIROMAC
ENVIROMAC
PORTABLE AIR CLEANER
PORTABLE AIR CLEANER
PORTABLE AIR CLEANER
PORTABLE AIR CLEANER
carries a 1-year warranty.
-Parts are replaced at no cost. Labor charges are extra.
The Cartridge filter and carbon filters are guaranteed for a period of (30) days. The Company’s responsibility and obligation
under the guarantee is limited to the repair or exchange of any defective parts, which have been returned prepaid, to the
factory or an authorized service depot, and which prove to be defective through normal use. Only prepaid returns will be
accepted unless previously authorized to be returned freight collect. Goods repaired under warranty will be returned
prepaid. If in the company’s judgment the repair is not covered by the warranty, parts will be billed with a small labor charge
and returned collect.
The conditions of the Guarantee are:
1) The unit must have been operated within its listed capacity.
2) The unit must not have been moved from the site of its original installation.
3) The WARRANTY CARD must be returned within (10) days of installation. (Failing this, the company will guarantee the
unit for a period of 12 months from the date of manufacture according to the Company’s records.)
Please return warranty card to one of the following addresses:
In Canada:
Enviroflex International Inc.
17 Brownridge Road, Unit 8,
Halton Hills, Ontario
L7G 0C6
Phone: 905-636-1177
Fax: 905-636-1178
In U.S.A.:
Enviroflex International Inc.
1051 Clinton St.
Buffalo, N.Y.
14206-2823
Phone: 716-883-2319
Fax: 716-892-2139
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
ENVIROMAC
ENVIROMAC
ENVIROMAC
ENVIROMAC
Return Business Reply Card. Retain Warranty Card.
Owner’s Name_________________________________________________________________________
Address______________________________________________________________________________
City____________________________State/Province_______________Zip/Postal Code______________
Contact Name______________________________ Contact Email Address_______________________
Installing Contractor’s Name______________________________________________________________
Model No.______________________Serial No.___________________Date of Installation____________
Reasons for Buying:
1) Improved Air Quality
2) Welding Smoke Removal
3) Other____________________________
Where did you hear about
1) Newspaper or Magazine?
this unit?
2) Telephone Directory
3) Trade Directory
3) Enviroflex
Distributor
4) Friend
5) Another company
6) Trade Show
7) Other___________________________
ENVIROFLEX®
M
ATERIAL
S
AFETY
D
ATA
S
HEET
I. PRODUCT IDENTIFICATION
Trade Name: Envirocoat
Chemical Name: Amorphous siliceous mineral-silicate Formula: Sodium-potassium-aluminum-silicate of
variable composition
II. PRODUCT INGREDIENTS
Ingredient Name: Perlite, Expanded milled may contain Crystalline Silica Quartz less than 1.0% %: 100
Permissible Exposure: 5mg/m
3
TWA Respirable dust re: OSHA PEL
III. PHYSICAL DATA
Appearance and Odor: White/off white powder; odorless Boiling Point: N/A Evaporation Rate: N/A Vapor Pressure: N/A
Specific Gravity (water=1): 2.35 Water Solubility (%): Slight Melting Point: N/A Vapor Density: (Aim1): N/A; %
% Volatile by Volume: N/A
IV. FIRE AND EXPLOSION DATA
Flash Point (Method): Nonflammable Unusual Fire or Explosion Hazards: None Flammable Limits: N/A
Extinguishing Media: N/A Special Fire-Fighting Procedures: None Auto-ignition Temperature: N/A
NFPA Flammable/Combustible Liquid Classification: N/A
V. HEALTH HAZARDS A. Summary/Risks
Summary: OSHA considers Perlite a nuisance dust and recommends a PEL of 5 mg/m
3
TWA respirable dust. Inhalation over long
periods of high amounts of any nuisance dust may overload lung clearance mechanism and make the lungs more vulnerable to
respiratory disease.
Medical Conditions Which May Be Aggravated: Pre-existing upper respiratory and lung disease (such as bronchitis, emphysema,
asthma, or others).
Target Organ(s): Lungs Primary Entry Route(s): Inhalation Acute Health Effect: Transitory upper respiratory irritant.
Chronic Health Effects: See Summary. Follow the safe handling practices shown on the product bag label.
V. HEALTH HAZARDS B. Signs/Symptoms of Overexposure
Inhalation: Coughing, irritation of nose and throat; congestion may occur upon overexposure Skin Absorption: N/A
Skin Contact: N/A Ingestion: Not hazardous. Generally regarded as safe by the FDA. Eyes: Temporary irritation and/or inflammation.
V. HEALTH HAZARDS C. First Aid/Emergency Procedures
Inhalation: Remove from dusty area; drink water to clear throat; blow nose to evacuate dust. Skin Contact: N/A
Skin Absorption: N/A Ingestion: Not hazardous, generally recognized as safe by the FDA Eyes: Do not rub eyes. Flush eyes with
copious amounts of water to remove any dust particles. Consult a physician if irritation persists.
Vl. REACTIVITY DATA
Stability: Material is stable. Hazardous polymerization will not occur. Chemical Incompatibilities: Hydrofluoric acid
Conditions to Avoid: None in designed use. Avoid contact with hydrofluoric acid. Hazardous Decomposition Products: Reacts with
Hydrofluoric acid to form toxic silicon tetra fluoride gas.
Vll. SPILL OR LEAK PROCEDURES
Procedures for Spill/Leak: Vacuum clean or wet sweep; avoid dusting; use a dust suppressant when sweeping.
Waste Management:
Not considered as hazardous waste by RCRA (40 CFR Part 261). Place waste and spillage in closed containers.
Dispose in approved landfill. RQ-N/A
VIII. SPECIAL PROTECTION INFORMATION
Goggles: Normally not required. You may use safety eyewear to protect from dusts. Gloves: Normally not required. You may use
gloves to protect overly sensitive skin. Respirator: Even though Perlite is a nuisance dust, we recommend the use of NIOSH approved
respirators to protect against silicosis producing dusts. Ventilation: Use adequate exhaust ventilation and/or dust collection to keep
dust levels below PEL.
Special Considerations for Repair/Maintenance of Contaminated Equipment: Insure proper respiratory protection.
IX. SPECIAL PRECAUTIONS
Storage Segregation Hazard Classes: N/A
***ALWAYS SEGREGATE MATERIALS BY MAJOR HAZARD CLASS***
Special Handling/Storage: Store in dry place. Repair all broken bags immediately. Avoid creating dust. Maintain good housekeeping
practice. Special Workplace Engineering Controls: Adequate ventilation and appropriate local exhaust where needed to keep dust
levels below PEL. Other: Comply with all Federal, State and local regulations.
As of the date of preparation of this document, the foregoing information is believed to be accurate and is provided in good
faith to comply with applicable Federal and State law(s). However, no warranty or representation with respect to such
information is intended or given.
In U.S.A.:
Enviroflex International Inc.
In Canada:
Enviroflex International Inc.
1051 Clinton St.
17 Brownridge Road, Unit #8
Buffalo, NY, U.S.A. 14206-2823
Halton Hills, Ontario, Canada L7G OC6
Phone :(716) 883-2319 Fax:(716) 892-2139
Phone:(905) 636-1177 Fax:(905) 636-1177
Effective:
November 14, 2008
Section 2A
Country:
Canada
Page 1 of 1
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
Precoat Instructions for ENVIROMAC
Precoat Instructions for ENVIROMAC
Precoat Instructions for ENVIROMAC
Precoat Instructions for ENVIROMAC
Filter
Filter
Filter
Filter
Prior To Initial Use
The cartridge filter has to be pre-coated with 2 cups of Precoat prior to initial use. The
precoat should be fed into the pickup hood at the end of the Snorkvac™ Arm. After pre-
coating the filter let the fan operate for two (2) minutes to allow the Precoat to settle on the
inside of the filter.
After Initial Precoat
The suction will deteriorate as the filter loads up with particulate. When it is time to clean the
filter you remove the filter, turn it upside down, blow it out on the outside with compressed
air then insert back into the machine and precoat the unit the same as the initial precoat
instructions.
The filter can be cleaned with water as the media does not retain any moisture. However,
getting rid of the water and particulate could be a problem as people are concerned with
dumping hazardous particulate down a drain.
You can dispose of the particulate in a bag if the filter was cleaned with compressed air.
Date: November 14, 2008
Section 2B
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
Washable Filters
Washable Filters
Washable Filters
Washable Filters
Field Applications:
Filtration of welding fumes, plasma & laser cutting, dump
stations, product recovery & general pollution control problem
applications.
The material is 100% polyester, which is especially suitable for the extraction of welding
smoke.
This material is characterised by uniform parallel pleats on the dust side. This gives the filter
the maximum square footage with a uniform pleat distance. Conventional pleating doesn’t
have this uniform pleating thus increasing the pressure drop due to overlapping the pleats
and minimizing the square footage of the filter. The end result is that the washable filter
does not plug up as quick and there is more airflow through the washable filter.
The material has a thickness of 0.022" and is used in filter cartridges and can be
automatically cleaned by pulsing the filter with compressed air. The filter can also be
washed with a detergent, as it does not retain any moisture.
Specifications:
Colour:
Available in black and white.
Weight:
Approximately 275 grams per square meter(8oz. per
square yard)
BIA Classification:
:
U.S.G. (see pages 3 and 4)
Air Permeability:
650 m³/hr. at 20MM W.G. (25cfm @ ½" W.G.
)
Temperature Resistance:
Standard 80º C (176º F). Please note when ordering to
state a higher temperature if it exceeds the standard
temperature rating.
Efficiency:
99.2%
Clean Off Behaviour:
Good
Date: November 14, 2008
Section 2
Page 1 of 4
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
Test Results
Test Results
Test Results
Test Results
1.
Test Basis:
ZH1/487 ABS 2 is a European test regarding filter
efficiencies of filter fabrics for dust extraction installations.
2.
Test Sample
Filter Fabric
2.1
Built-up:
Filter Fabric, single Layer
2.2
Type Name:
Open pleat washable
2.3
Material Name:
Polyester washable
2.4
Approved Category: U.S.G.
3.
Manufacturer’s Data of the Filter Fabric
3.1
Materials and Type
Polyester Fabric
3.2
Surface Weight:
280 gr/m²(8.25 oz./sq. yd.)
3.3
Air Permeability:
700 m³/m
²
/ hr at 200 Pascal (38 CFM @ 0.8" W.G.)
3.4
Dust Side:
Parallel Lined (25 CFM per square foot @ 0.5" W.G.)
3.5
Colour:
Black or White
4.
Penetration Test of the Filter Fabric
4.1
Filtration Speed:
0.056 m/s (11 ft./min)
4.2
Quartz dust
Concentration:
200 +/- 20 mg/m³ (.087 grains/ft³)
4.3
Requirements
Category-G-Maximum Penetration Degree is 0.5%
Date: November 14, 2008
Section 2
Page 2 of 4
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
4.4
Test Results
Average Penetration Degree 0.13% (tests)
Standard aberration:
0.05%
At a filtration speed of 0.056 m/s the average penetration degree is 0.5%. The test
requirements for the filter fabric efficiency for the category U.S.G. are successful.
Pressure Drop
Pressure Drop
Pressure Drop
Pressure Drop
5.1
Filtration Speed:
0.056 m/s (11 ft./min.)
5.2
Filter Load
200 m³/m²/hr. (10.9 ft³/ft²/min.)
5.3
Test Results
Average Pressure Drop:
79 pa (6 tests on clean material) (0.3" W.G.)
6
Air Permeability Test:
506 m³/m²/hr (27.66 ft³/ft²/min.)
The air permeability of the filter material is ascertained at a differential pressure of
200 Pa. (0.8" W.G)
7.
Surface Weight Test:
273 g/m² (8.05 oz.yd.²
8.
Notes:
The requirements are fulfilled.
CLAR
CLAR
CLAR
CLARIFICATION OF EUROPEAN STANDARD ZH1/487
IFICATION OF EUROPEAN STANDARD ZH1/487
IFICATION OF EUROPEAN STANDARD ZH1/487
IFICATION OF EUROPEAN STANDARD ZH1/487
The BIA is a government agency, which directs the setting up of rules and standards in order
to meet certain safety and quality standards in Europe. One of those is the AH1/487 ABS 2
test procedure for different filtering media used in dust collection equipment. The test is
carried out on small media samples, and the test dust is standardized. The approach velocity
on the media during the test is standardized on 11 F.P.M. (11:1 A/C ratio). During the test, a
quantity of approximately 0.078 Gr/cu.ft. of dust is fed to the media, and the penetration is
measured. In this way a certain penetration is determined which rates the media in
preclassified levels, the so called U.S.G. or C. The U media's are the lowest efficiency
medias; the C medias are the highest efficiencies. The maximum allowable penetration
degrees for the different classifications are:
Date
November 14, 2008
Section 2
Page 3 of 4
ENVIROFLEX
FOR A HEALTHIER WORK ENVIRONMENT
IN U.S.A.
ENVIROFLEX INTERNATIONAL INC.
1051 CLINTON ST.
BUFFALO NY, USA 14206-2823
TEL. (716) 883-2319 FAX (716) 892-2139
TOLL FREE 1-866-ENV-FLEX
Internet: http://www.enviroflex.com
Email: Info@enviroflex.com
IN CANADA
ENVIROFLEX INTERNATIONAL INC.
17 BROWNRIDGE RD. UNIT 8
HALTON HILLS, ONTARIO, CANADA, L7G 0C6
TEL. (905) 636-1177 FAX (905) 636-1178
TOLL FREE 1-877-ENV-FLEX
Internet: http://www.enviroflex.com
Email: info@enviroflex.com
U: 5% S: 1% G: 0.5% C: 0.1%
In point 4.3 the applications categories are described above are specified for the media
tested. In case of the "open pleat washable" this media has obtained the G (U&S
automatically) level by performing with a penetration degree less than 0.5%. In Europe,
there are certain listings, which prescribes certain classified filter medias for certain types of
dust. Outside Europe, such listings are not available yet. In point 5.4 the air permeability is
mentioned as value provided by the manufacturer of the media. The value is given in
m³/m²/hr. at a pressure drop of 20MM W.G. (approximately 0.8 inches of water). The actual
measured air permeability during the test was 506 m³/m²/hr. (27.66 CFM/Sq.Ft./Min.) point
8 in the test results.
For Welding fume, generally the "open pleat washable" can be used very successfully.
However, special treatment on the media utilizing a Precoat should be applied during
commissioning of the filter unit. By using this special silicone based Precoat a much better
reverse jet-pulse cleanability of the media is obtained.
Regarding washing of the "open pleat washable" polyester medias, we recommend a
medium pressure cleaner using warm water (max.60 deg. C) with Precipiclean
. The
nozzle of the cleaner should be approximately 20 inches away from the filter in order not to
damage the media.
Date: November 14, 2008
Section 2
Page 4 of 4
6” Bench Mount Model
No Description Qty Arm
model
103.1028
(10ft. Arm)
Part
Number
1
Joint 1
1 103.1028.1
2 Joint
2
1 103.1028.2
3 Joint
3
1 103.1028.3
4 Joint
4
1 103.1028.4
5 Joint
5
1 103.1028.5
6 Joint
6
1 103.1028.6
7 Joint
7
1 103.1028.7
8 Joint
8
1 103.1028.8
9
Friction insert I
70
2
103.1028.9
10
Friction insert II
60
2
103.1028.10
12 Tube I 160
1
103.1028.11
13 Tube II 160
1
103.1028.12
14
Reinforcing
element I 160
2
103.1028.13
15
Reinforcing
element II 160
1
103.1028.14
21 Spring II, l=190
2
103.1028.15
22
Outer sleeve
160
1
103.1028.16
23 Inner
sleeve
160
1 103.1028.17
25 Orifice
160
1 103.1028.18
26 Axis
I
1 103.1028.19
27 Axis
II
1 103.1028.20
28 Lever
1 103.1028.21
29 Sleeve
2 103.1028.22
30 Support
plate
1 103.1028.23
31
Screw with
mushroom head
M10x30-4.8
8
103.1028.24
32 Nut
M10-5-C
8 103.1028.25
33a
Regular washer
10.5
10
103.1028.26
34
Spring washer
Z10.2
8
103.1028.27
35
Screw with
mushroom head
M8x30-4.8
8
103.1028.28
36 Nut
M8-5-C
9 103.1028.29
37
Regular washer
8.2
1
103.1028.30
38
Spring washer
Z8.2
9
103.1028.31
41
Spring washer
Z6.1
2
103.1028.32
42 Nut
M6-5-C
2 103.1028.33
46
Self-locking nut
M14x1.5-5-B
4
103.1028.34
47
Disk spring DI
60x14.5x3
4
103.1028.35
48
Disk spring DI
50x14.5x2.2
4
103.1028.36
51
Steel cable
3.5, l=450
1
103.1028.37
52
Bow rope clamp
5
1
103.1028.38
53
Screw M8x25-
3.6-C
1
103.1028.39
54
Self-locking nut
M8-5-B
1
103.1028.40
55
Clamping eye
10.5
1
103.1028.41
57
Screw
M14x1.5x60-
8.8-B
2
103.1028.42
58
Screw
M14x1.5x55-
8.8-B
2
103.1028.43
60 Hood
315/160
1
103.1028.44
61 Handle
160
1 103.1028.45
62 Light kit dome
1
103.1028.46
63
Shutter of inlet
160
1
103.1028.47
64 Wire seal GH6
1
103.1028.48
65 Protecting
plate
1 103.1028.49
66
Screw WP
M4x16
2
103.1028.50
67 Plug
I
1 103.1028.51
68 Plug
II
1 103.1028.52
69
Regular washer
15 (for wood
construction)
6
103.1028.53
70
Screw with
mushroom head
M6x16-4.8
2
103.1028.54
73
Lubricating
nipple C M8x1
1
103.1028.55
74 Wing nut M6
1
103.1028.56
75
Internal
wrenching
screw M8x20-
8.8
1
103.1028.57
79
Steel rivet
3.2x8
4
103.1028.58
79b
Steel rivet
3.2x8
4
103.1028.59
80 Handle
1 103.1028.60
81
Flexible hose
ST-160,
l=535mm (21”)
1
103.1028.61
82
Gear clamp
OST-160
6
103.1028.62
84
Flexible hose
ST-160
l=640mm (25”)
1
103.1028.63
85
Flexible hose
ST-160
l=430mm (17”)
1
103.1028.64
P1
Joint’s wheel
160
1
103.1028.65
P2 Connector
I
4 103.1028.66
P3 Screw
M8x20
12 103.1028.67
P4
Self-locking nut
M8
12
103.1028.68
P5
Regular washer
8.4 C
12
103.1028.69
P7
Friction insert
30x8x6
4
103.1028.70
P8
Reinforcing
element IV
1
103.1028.71
P9
Disk spring
12.5x6.2x1
8
103.1028.72
φ
6” Bench Mount Model
No
Description
Qty
Arm model
103.1028
(10ft. Arm)
Part Number
1
Joint 1
1
103.1028.1
2
Joint 2
1
103.1028.2
3
Joint 3
1
103.1028.3
4
Joint 4
1
103.1028.4
5
Joint 5
1
103.1028.5
6
Joint 6
1
103.1028.6
7
Joint 7
1
103.1028.7
8
Joint 8
1
103.1028.8
9
Friction insert I
70
2
103.1028.9
10
Friction insert II
60
2
103.1028.10
12
Tube I 160
1
103.1028.12
13
Tube II 160
1
103.1028.13
14
Reinforcing
element I 160
2
103.1028.14
15
Reinforcing
element II 160
1
103.1028.15
21
Spring II, l=190
2
103.1028.21
22
Outer sleeve
160
1
103.1028.22
23
Inner sleeve 160
1
103.1028.23
25
Orifice 160
1
103.1028.25
26
Axis I
1
103.1028.26
27
Axis II
1
103.1028.27
28
Lever
1
103.1028.28
29
Sleeve
2
103.1028.29
30
Support plate
1
103.1028.30
31
Screw with
mushroom head
M10x30-4.8
8
103.1028.31
32
Nut M10-5-C
8
103.1028.32
33a
Regular washer
10.5
10
103.1028.33a
34
Spring washer
Z10.2
8
103.1028.34
35
Screw with
mushroom head
M8x30-4.8
8
103.1028.35
36
Nut M8-5-C
9
103.1028.36
37
Regular washer
8.2
1
103.1028.37
38
Spring washer
Z8.2
9
103.1028.38
41
Spring washer
Z6.1
2
103.1028.41
42
Nut M6-5-C
2
103.1028.42
46
Self-locking nut
M14x1.5-5-B
4
103.1028.46
47
Disk spring DI
60x14.5x3
4
103.1028.47
48
Disk spring DI
50x14.5x2.2
4
103.1028.48
51
Steel cable
3.5, l=450
1
103.1028.51
52
Bow rope clamp
5
1
103.1028.52
53
Screw M8x25-
3.6-C
1
103.1028.53
54
Self-locking nut
M8-5-B
1
103.1028.54
55
Clamping eye
10.5
1
103.1028.55
57
Screw
M14x1.5x60-
8.8-B
2
103.1028.57
58
Screw
M14x1.5x55-
8.8-B
2
103.1028.58
60
Hood
φ
315/160
1
103.1028.60
61
Handle 160
1
103.1028.61
62
Light kit dome
1
103.1028.62
63
Shutter of inlet
160
1
103.1028.63
64
Wire seal GH6
1
103.1028.64
65
Protecting plate
1
103.1028.65
66
Screw WP
M4x16
2
103.1028.66
67
Plug I
1
103.1028.67
68
Plug II
1
103.1028.68
69
Regular washer
15 (for wood
construction)
6
103.1028.69
70
Screw with
mushroom head
M6x16-4.8
2
103.1028.70
73
Lubricating
nipple C M8x1
1
103.1028.73
74
Wing nut M6
1
103.1028.74
75
Internal
wrenching
screw M8x20-
8.8
1
103.1028.75
79
Steel rivet
3.2x8
4
103.1028.79
79b
Steel rivet
3.2x8
4
103.1028.79b
80
Handle
1
103.1028.80
81
Flexible hose
ST-160,
l=535mm (21”)
1
103.1028.81
82
Gear clamp
OST-160
6
103.1028.82
84
Flexible hose
ST-160
l=640mm (25”)
1
103.1028.84
85
Flexible hose
ST-160
l=430mm (17”)
1
103.1028.85
P1
Joint’s wheel
160
1
103.1028.P1
P2
Connector I
4
103.1028.P2
P3
Screw M8x20
12
103.1028.P3
P4
Self-locking nut
M8
12
103.1028.P4
P5
Regular washer
8.4 C
12
103.1028.P5
P7
Friction insert
φ
30x8x6
4
103.1028.P7
P8
Reinforcing
element IV
1
103.1028.P8
P9
Disk spring
12.5x6.2x1
8
103.1028.P9
Drawing 19. (6” arm) Damper – both Wall Mounted and bench mount.
70
80
40
41
42
13
40
41
42
79
70
74
41
33a
28
33a
26
79
30
29
79
25
27
29
D
2
Drawing 13. (6” arm) Socket of SNORKVAC™ arm – Bench Mount.
21
53
51+55
52
37
23
22
57
47
1
9
32
34
31
3
47
69
46
31
34
32
69
47
4
9
2
46
31
34
32
31
34
32
47
57
54
12
15
75
38
36
73
32
34
31
A
2
Drawing 12. (6” arm) SNORKVAC™ bench mount arm
82
82
82
82
82
82
85 84
81
12
13
A
2
C
1
D
1
B
2