Full Text Searchable PDF User Manual
Save your power bill with Hydro Hero
ENERGY EFFICIENT SOLUTIONS
EES
> the heat pump specialists
f. 0800 EES 123
p. 09 973 5993
e. info@eesnz.co.nz
ENERGY EFFICIENT SOLUTIONS
EES
> the heat pump specialists
POWERED BY
Aqua-Man
Outdoor Range
Dark-Knight
Indoor Range
Capacity (L)
Rated input / output HP (kW)
Rated input / output electric (kW)
Max current (amps)
Max input power (kW)
Rated output water temp (°)
Power supply (V)
COP at 20° (EN255-3)
COP at 15° (EN255-3)
COP at 7° (EN255-3)
Refrigerant
Noise level dB(A)
Air flow (m3/h)
Tank construction
Dimensions (mm)
Pressure rated / max (MPa)
Gross weight (KG)
Compressor specification
Warranty heat pump / Cylinder
260L
0.88kW / 3.6kW
2kW / 2kW
15 amps
3.6kW
55° - 70°
220V
4.52
3.88
2.82
R417a
48 dB(A)
900 m3/h
Stainless Steel
Ø
650mm x 1760mm
2.8MPa / 3.6MPa
98KG
Panasonic 2P17S225ANQ
6 Years / 10 Years
190L
0.88kW / 2.8kW
2kW / 2kW
15 amps
3.6kW
55° - 70°
220V
4.52
3.88
2.82
R417a
48 dB(A)
900 m3/h
Stainless Steel
Ø
650mm x 1485mm
2.8MPa / 3.6MPa
83KG
Panasonic 2P17S225ANQ
6 Years / 10 Years
Capacity (L)
Rated input / output HP (kW)
Rated input / output electric (kW)
Max current (amps)
Max input power (kW)
Rated output water temp (°)
Power supply (V)
COP at 20° (EN255-3)
COP at 15° (EN255-3)
COP at 7° (EN255-3)
Refrigerant
Noise level dB(A)
Air flow (m3/h)
Tank construction
Dimensions (mm)
Pressure rated / max (MPa)
Gross weight (KG)
Compressor specification
Warranty heat pump / Cylinder
260L
0.7kW / 2.8kW
2kW / 2kW
15 amps
3.3kW
55° - 70°
220V
4.21
3.88
2.95
R134a
48 dB(A)
450 m3/h
Stainless Steel
Ø
650mm x 1760mm
2.4MPa / 3.0MPa
98KG
Panasonic 6PS174EAA21
6 Years / 10 Years
190L
0.7kW / 2.8kW
2kW / 2kW
15 amps
3.3kW
55° - 70°
220V
4.21
3.88
2.95
R134a
48 dB(A)
450 m3/h
Stainless Steel
Ø
650mm x 1485mm
2.4MPa / 3.0MPa
83KG
Panasonic 6PS174EAA21
6 Years / 10 Years
Specifications
Aqua-Man 190L
Aqua-Man 260L
Specifications
Dark-Knight 190L
Dark-Knight 260L
*Mean temperature in Auckland 2013 15.9°
*Mean temperature in Auckland 2013 15.9°
Save your power bill with Hydro Hero
ENERGY EFFICIENT SOLUTIONS
EES
> the heat pump specialists
POWERED BY
Heating
Possible
-15
º
C
Heating
Possible
-15
º
C
Hydro Hero
Heat Pump Water Heater
INSTRUCTIONS
'LDJUDP of WDQN heat pump
Top Cover
Upper Cover
Vent Pipe
Ventilation Fan
Host Chassis
Safety Valve Hole
Hand Grip
Supporting Frame
Cold Water Inlet
/Drainage Hole
Screen Panel
Evaporater
Magnesium Anode Hole
Electric Heater Cover
Electric Heater Hole
Decoration Bar
Electric Board
Compressor
Tank Cover
Decoration Panel
Left/Right Decoration Bar
Condensate Drain Hole
Circulation Water Hole
Wiring Hole
Power Line
Temp Sensor Tube Hole
Circulation Water Hole
Hot Water Outlet
Operation
RIFRQWUROOpanel
工作模式指示
机器状态指示
调节时钟指示
当前时间显示
定时开显示
定时关显示
定时时段显示
辅电加热指示
机器报警指示
水温高温提示
设定水温显示
用水温度显示
水温渐变显示
注:当用水温度超过55℃时,显示屏上"高温"提示亮。
Set Temperature
High Temperature
Alarm
Auxiliary Heater
Status
HTG: Heating
DEF: Defrost
WARM: Keep warm
Working Mode
Time adjustment
Time
Timer On
Timer Off
Timer Period
Water Temperature
Temperature Gradient
Note:
When the water temperature exceeds 55
℃
, the indicator light on display.
Press “MODE” button for 5 seconds; enter the Parameter setting status, the main parameter code as
below sheet:
Type
Code
Parameter Name
Setting Range
Factory Setting
Unit
Remark
Temperature
Control
F11
Setting temperature
5-70
55
C
F12
Difference in Temp.
1 - 30
5
C
F13
Determine Heat pump stop
ambient temp.
-10
– 5
-7
C
F14
Highest temp. for heat pump
40
– 60
55
C
F15
Turn on or off electric
heater mode
0 - 1
1
-
F16
Ambient temp. for start electric
heating
-10 - 20
0
C
F17
Turn on or off electric heater
for sterilization function
0-1
1
F18
Sterilization cycle
1-990
336
hour
F19
Water thermal sensor
temp. amendment
-5
– 5
0
C
Compressor
F21
Compressor start delay
0
– 10
3
minute
F28
Econ mode turn on or off
electric heater
0 - 1
1
F29
Heat pumps working or not in
heater mode
0 - 1
1
Defrost
F31
Defrost start temp.
-20
– 20
-2
C
F32
Defrost finish temp.
0
– 50
25
C
F33
Defrost start time
1
– 999
30
minute
F34
Max. defrost time
Off, 1
– 99
5
minute
Alarm
F50
Low pressure alarm mode
0 - 2
2
-
F51
Auto resume times of low
pressure alarm
0
– 10
3
time
F52
Reset time of external alarm
auto resume times
0
– 999
60
minute
F54
Electric heater overheat
protection
0 - 2
2
-
F55
Overheat resume time
0-10
3
-
F56
Alarm resume time
0-999
60
C
F57
Exhaust temp. protection
mode
0
– 2
1
-
F58
Exhaust protect temp.
50
– 125
110
C
F59
Exhaust temp. protection
Return difference
1
– 30
10
C
Function
Setting
F61
Memory status when power off
Yes/No
Yes
-
F69
Communication baud
24/48
24
-
Technical Operation
Remark
V
:
When enter Parameter setting status, press “up” or “down” to choose parameter code; after choose one, press “Timer”
button to show this code’s setting value, and press “up” or “down” can set the value; After finish setting, press “Timer”
button to confirm and return to Parameter code status.
Electronic
expansion
valve(EEV)
F70
EEV opening query
0
–480
--
F71
EEV control mode
0
–2
0
F72
Manually set EEV opening
100
–480
350
F73
Set EEV superheat degree
-15
–15
5
F74
Set EEV discharge temp
85
–110
92
F79
Return gas temp.
--
System
Setting
F80
Password
OFF
0001 -- 9999
4321
-
“OFF” means no
password.
Set
“0000” to
clear password.
F85
Display sterilization total time
-
-
hour
Testing
F98
Force defrosting (refrigeration)
Control panel
display
“AdF”
Start compressor, 4-way
valve and fan motor. Press
any key to exit or 20 minutes
it will exit automatic.
Error Handling:
ERROR
CODE
ERROR STATUS
REASONS
ERROR HANDLING
A1
Thermal sensor
alarm
Water temp. sensor open
circuit or short circuit.
1. Check the water temp. sensor
connection.
2. Change the water temp. sensor.
A2
Condenser coil
sensor alarm
Condenser coil temp.sensor
open circuit or short circuit.
1. Check the condenser coil temp.
sensor connection.
2. Change the coil sensor.
A3
Exhaust sensor
alarm
Exhaust temp. sensor open
circuit or short circuit.
1. Check the exhaust temp. sensor
connection.
2. Change the exhaust temp. sensor.
A4
Ambient temp.
sensor alarm
Ambient temp. sensor open
circuit or short circuit.
1. Check the Ambient temp. sensor
connection.
2. Change the ambient temp. sensor.
A5
Low /High pressure
alarm
1.1. High pressure protection
switch off.
1.2. Ambient temp. too high or
water heat exchanger dirty
block.
2.1. Low pressure protection
switch off.
2.2. Leakage of refrigerant.
1.1Check or change the high
pressure protector.
1.2. Check if the surround temp. is
too high, or clean the heat
exchanger of water tank.
2.1. Check or change the low
pressure protector.
2.2. Supply refrigerant and check if
there is any leakage.
A6
(Auxiliary) electric
heater protection
overheat alarm
1. Electric heater protection
switch off.
2. Tank water temp. too high.
1. Check if the water temp. is as LCD
display, or if water temp. is too
high.
2. Change the Electric heater.
A7
Exhaust temperature
too high
1. Lack of refrigerant.
2. Mix with air in system.
3. Lack of lubricating oil.
1. Supply refrigerant.
2. Re-vacuumizing, and fill in
refrigerant.
3. Change the lubricating oil of
compressor.
A8
Condensate drain
hole blocked
1.condensate pipe blocked
;
2.Machine drain hole blocked
;
1.Check condensate pipe is blocked
or not.
2.Check machine drain hole is
blocked or not.
A9
Return gas temp.
sensor alarm
Return gas temp. sensor open
circuit or short circuit.
1.Check the Return gas temp.
sensor connection.
2. Change the ambient temp. sensor.
- -
Screen no display or
display insufficiency
1. No plug in power.
2. Mainboard and operation
panel communication break
off.
1. Check the power line and voltage.
2. Reconnect the line of
mainboard and operation panel.
3.
Change
the
mainboard
or
operation panel.
NOTE:
1. When the unit has error, the buzzer of the operation panel will make an alarm sound, and there will
show “Alarm” on the screen panel.
2.
“ERROR CODE” will show on temperature display location by alternately.
3. Part of the error alarm can be automatically restored (resumed). That is the appeared alarm can be
eliminated by electronically controlled self-test.
4. Some of the error alarm is caused by large fluctuation of the external power, by this, just power off and
restart the unit to clear the error.
5. When the machine has error alarm and restart still can not eliminated error, please contact the after
service as soon as possible for solution.
Maintenance and service
Examination before trial run
1. Check the water tank is filled with water, and open the water outlet tap till water flow out.
2. Check the water pressure is normal (0.15Mpa~0.7Mpa).
3. Check the air inlet or outlet is well connected; and the air outlet pipe heat insulation is completed.
4. Check the power supply voltage is normal, whether according with the nameplate requirement.
(Range ± 10%).
5. Check whether the equipped parts are screwed /locked well.
6. Check whether the wirings are according with the Circuit diagram, and the earth-wire is
connected.
7. Check whether the wind inlet and outlet has been cleaned up and no obstacle.
8. Check whether the condensate drain pipe is connected well and no blockage.
9. After power-ON, check the control panel display is normal.
Trial running
1. After the machine starts, to hear and determine whether there is abnormal sound or collision
during operation, if there is abnormal sound, stop the unit immediately and check for it until there
is no abnormal sound to continue operation.
2. For the first time power on, the compressor will have 3 minutes delay protection function.
3. Observe whether the drainage of condensate water is smooth, prevent the chassis stagnant or
spill water.
4. For the first time discharge hot water or start the units after a long time closure, the water tap of
outlet pipe may flow muddy water, this is a normal phenomenon, and continue to drain for a period
of time can be cleared.
5. After stop operation for a long time, there may have condensation water hereabout the air outlet or
pipe (especial in humidity weather), this is a normal phenomenon, use a dry washcloth to clean it
or by air dry.
6. The advance setting parameters of the operation panel has been set at the factory, users no need
to reset it, the maintenance person should be carefully set if needed.
Maintenance and service
1. After carry and move the unit by the first time installation, and connects the water pipes and filled
the tank with water. The machine should be rest for 1-2 hours before start trial running.
2. The water heater inlet filter needs to be cleaned once per 3 months. At the same time, per half
year we suggest draining all the storage water and repeatedly wash for 2-3 times to remove the
dirt and sediment.
3. To keep the unit in good heating performance, suggest cleaning the Air inlet /outlet filter net per
month, or using high pressure air tube to clean the Heat exchanger. Be careful not to damage the
copper tube.
4. Clean the Electric Heater per 6 months. (When clean the Electric Heater or Heat Exchanger must
cut off power supply.)
5. Change the Anode (Magnesium rod) per 6 months for better anticorrosion and antiscale.
According to different water quality, change the Anode rod when it
’s expended.
6. When clean the Tank, Electric Heater, Heat Exchanger or Anode rod must cut off power supply.
7. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person.
8. Special statement: for what does not in accordance with the requirements of above maintenance
and service work lead to the failure problem, does not apply to our warranty scope.
Heat Pump main unit disassembly
If want to check and maintain the top main parts of the unit, should disassembly the cover of the unit,
follow the below steps (Fig.5, 6) to process.
(Fig.5) (Fig.6)
1. Move up the control panel and its components-1(including control panel
、
decorative panel,
decorative aluminum profile
、
decorative strip) vertically 15-20mm, then pull it out horizontally to
separate hook A-2 from hook A-3 until exposed butt splice connector;
2. Disconnect control panel with butt splice connector
;
3. Remove all screws-5 from the bottom of the top cover.
4. Release the power line from the top cover of fixed terminal, to prevent the power line stuck when
move up the top cover.
5. Finally, remove the block objects (e.g. air ducts etc.) from the air inlet /outlet, holding both sides of
the top covers and move it up.
6
4
5
3
3
2
2
ON/OFF
CLOCK
TIMER
MODE
1
&ircuit diagram
Heat pump WITH auxiliary electric heater:
BLACK/
12V
模式
定时
时钟
开/关
C
S
R
Elect Valve Fan
Comp
1
2
L N
3
2
L
POWER SUPPLY
YELLOW/GREEN
Transformer
WATER TEMP.SENSOR
OPERATION PANEL
ELECTRIC.HEATER
YELLOW/GREEN
4-WAY VALVE
FAN MOTOR
YELLOW/GREEN
ELECTRIC HEATER PROTECTOR
PRESURE PROTECTOR
Electronic expansion valve
AMBIENT TEMP.SENSOR
COIL TEMP.SENSOR
EXHAUST TEMP.SENSOR
RETURN GAS TEMP. SENSOR
N
B
XS
HI
LOW
COMPRESSOR
5
RED/
220V