PDF User Manual

  1. Home
  2. Manuals
  3. Krog Iversen & Co. SCAN 25 Instructions For Installation And Use Manual

Krog Iversen & Co. SCAN 25 Instructions For Installation And Use Manual

SCAN 25-2

Made by: Krog Iversen & Co.
Type: Instructions For Installation And Use
Category: Wood stove
Pages: 4
Size: 0.28 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

SCAN 25/25-5

I N S T R U C T I O N S   F O R 

I N S T A L L A T I O N   A N D   U S E

MONTERINGSVEJLEDNING

med brugs- og fyringsanvisning

Indhold:

Gene

relle

 råd

 og anvisn

inge

r  . . . . . . 

. . . .

2-3

 Rekl

amationsret

          

Type- og miljøgodkendel

se

          Udpakni

ng

          

Tilb

eh

ør til din pejs

          M

on

tering af kakle

r og fedtsten

          K

val

itetskontrol

          

Anmeldelsespligt

          S

kor

stenstjek

          S

kor

stensløsninger

          B

ær

ende under

lag

          B

ndbar eller ikke bræn

dbar

 væg

          Gulvp

lade

          V

arm

efordeling

          Juste

rskrue

          

Typeskilt

          Produktionsnr

.

          S

erv

ice

pakke

Monte

ring

svej

lednin

g. . .

 . . . . . . . . . . . . . .

4-7

Tilslutning

 til eksisterend

e/muret skorsten

 

Tilslutning topafgang til stålsko

rsten

 Forbræ

ndin

gsluft udefra

Bru

gs-

 og fyring

sanvi

sni

ng

 . .

 . . . . .

 . . . .

8-10

Ve

dligeholdelse af pejs

eovnen

 Håndtering 

af 

brændsel

 

Optænding og fyring

Fej

lsøgn

ing

 . . . . . . . . . . . . . . . . . . 

. . . 

. . 

. 1

1

SC

AN

 3

B

R

U

G

S

A

N

V

I

S

N

I

N

G

Til 

de

nn

Br

ug

sa

nv

isn

ing

 h

ør

er

 o

gs

å 

en

 

ge

ne

re

l M

on

te

rin

gs

ve

jle

dn

ing

.

Ud

ga

ve

 0

3.

03

 - 

DK

M

O

N

T

E

R

IN

GS

V

E

J

L

E

D

N

IN

G

m

e

d

b

rug

s-

 o

fyrin

g

sa

n

vis

ni

n

g

Ind

h

o

ld

:

G

e

n

e

re

lle

 r

å

d

 o

g

a

n

vi

sn

in

g

e

r

.

.

.

.

.

.2

-3

R

e

kl

a

m

a

tio

n

sr

e

t

T

yp

e

-

o

g

m

ilj

ø

g

o

d

ke

n

d

e

ls

e

U

d

p

a

kn

in

g

T

ilb

e

h

ø

til

d

in

p

e

js

M

o

n

te

ri

n

g

a

f

ka

kl

e

r

o

g

fe

d

ts

te

n

K

va

lit

e

ts

ko

n

tr

o

l

A

n

m

e

ld

e

ls

e

sp

lig

t

S

ko

rs

te

n

st

je

k

S

ko

rs

te

n

sl

ø

sn

in

g

e

r

B

æ

re

n

d

e

u

n

d

e

rl

a

g

B

n

d

b

a

r

e

lle

r

ik

ke

b

n

d

b

a

r

g

G

u

lv

p

la

d

e

V

a

rm

e

for

d

e

lin

g

S

e

lv

lu

kk

e

n

d

e

g

e

Ju

st

e

rs

kr

u

e

T

yp

e

sk

ilt

P

ro

d

u

kt

io

n

sn

r.

S

e

rv

ic

e

p

a

kk

e

M

o

n

te

ri

n

g

sv

e

jle

d

n

in

g

.

.

.

.

.4

-7

T

ils

lu

tn

in

g

til

e

ks

is

te

re

n

d

e

/m

u

re

t

sk

o

rs

te

n

T

ils

lu

tn

in

g

to

p

a

fg

a

n

g

 t

il

st

å

ls

ko

rs

te

n

F

o

rb

n

d

in

g

sl

u

ft

u

d

e

fr

a

B

ru

g

s-

o

g

 f

yr

in

g

sa

n

vi

sn

ing

 .

 .

.

.

.

.8

-1

0

V

e

d

lig

e

h

o

ld

e

ls

e

a

p

e

js

e

o

vn

e

n

H

å

n

d

te

ri

n

g

a

f

b

n

d

se

l

O

p

n

d

in

g

o

g

fy

ri

n

g

F

e

jls

ø

g

n

ing

.

.

.

.

.

.

.

.

.

.

11

T

il

d

e

n

n

e

m

o

n

te

ri

n

g

sv

e

jle

d

n

in

g

h

ø

re

r

o

g

 e

n

se

p

a

ra

t

b

ru

g

sa

n

vi

sn

in

g

fo

r

d

e

n

e

n

ke

lte

p

e

js

.

U

d

g

a

ve

0

2

/0

3

-

D

K

Til d

en

ne

 m

on

teri

ng

sve

jled

nin

g h

øre

r o

gså

 en

 

sep

ara

t b

rug

san

vis

nin

g fo

r d

en

 en

kel

te p

ejs

.

Udg

ave 02/03 - DK

Edition 12.05 - GB

This manual is accompanied by a pamphlet 
with General Instructions for Installation.

Approved according to EN 13240 2003

Krog Iversen & Co. A/S - DK-5492  Vissenbjerg

Declaration of Conformity

Manufacturer:

Krog Iversen & Co. A/S

DK - 5492 Vissenbjerg

Product:

SCAN 25

Description of product:

Room heater for closed operation

This product complies with the requirements

of the directive

CPD 89/106/EEC

Applied to harmonized standard EN 13240

Signature: _____________________________
         Managing director  Henning Krog Iversen

 


background image

Ceramic smoke deflectors

Lift up the lower ceramic smoke deflector, 
pull out the pins in the lateral combustion 
chamber plates and remove the deflector. The 
upper deflector is removed in the same way.

You have chosen a product from one of Europe's leading 
manufacturers of wood-burning stoves. We are convinced 
that your stove will be to your full satisfaction and give you 
many hours of pleasure if you follow the advice and instruc-
tions of this manual.

Please read this manual as well as the 

General Instructions 

for Installation

 before beginning the installation.

Congratulations on your new SCAN stove!

3

Clean combustion

The SCAN 25 uses the "CB technique" 
(Clean-Burn) to ensure an optimally clean 
combustion. The extra combustion air is 
preheated and led into the combustion 
chamber close to the ceramic smoke 
deflector.  

1

4

1   

Ashtray.

 When you open the door, you have access 

to the ashtray, which is placed below the combustion 
chamber. 

Attention! Be careful when you empty ashes 

from the stove. There may be embers left for up to 24 
hours after the stove was last used.

2   

Lid for ashtray.

 Under the ashtray you will find a lid to 

put on top of the ashtray when you carry it out for empty-
ing.

3   

Handle for shaking grate.

 The stove is equipped with a 

shaking grate. When you activate the grate handle, the 
ashes from the combustion chamber are emptied into the 
ashtray.

4  

Regulation for primary air.

 Push the button sideways. 

Left position is closed and right position is open. The 
primary air is used when lighting and refuelling the stove. 
It should always be closed during continuous firing.

5  

Regulation for combustion air.

 Push the button side-

ways. Left position is closed and right position is open. 
The air is used for combustion and regulates the output 
of the stove. 

SCAN 25/25-5

The ashtray, shaking grate, and primary air should always 
be closed during continuous firing.

2

5

You should read this manual as well as the 

General Instructions for Installation

 before beginning the installation.

 


background image

Adjustment of the handle

The handle can be loosened and adjusted at the lower 
closing hook with a hexagon spanner.

Accessories

For this model you can have the following accessories:

Handle

The handle is elegantly integrated on the moul-
ding below the door. Pull out the handle to 

Self-closing door (BA 1)

The door is prepared with a self-closing function at the factory. 
If you tighten the spring with the hexagon spanner, the door will 
close automatically when you let go of it.

•  Special elbow with wall sleeve and cover ring for SCAN 25 

with revolving base (see separate instructions)

•  Special adaptor for steel chimney for SCAN 25 with revol-

ving base (see separate instructions)

•  Shaped floor plate (steel or glass)

•  Connection piece for fresh-air intake (with firm base)

SCAN 25/25-5

SCAN 25 with revolving base (SCAN 25-5)

Mounting with elbow:

See separate instructions delivered with the stove.

Mounting with direct connection to steel chimney:

Should only be done in accordance with the instructions from 
an authorised SCAN dealer. See separate instructions deliv-
ered with the stove.

The warranty is invalid if the above is not followed.

The stove (with firm base) can be prepared for an external air supply 
where fresh air is let directly into the combustion chamber (can also 
be done subsequently by the authorized dealer).

Combustion air %

Primary air %

Max. fuel, kg

Fuel consumption, kg/h

90

60

2

2

Adjustment of the air + fuel consumption (EN 13240): 

 


background image

Warranty conditions

All SCAN wood-burning stoves and inserts are made of first-class mate-
rial and are subject to a strict quality control before they leave the fac-
tory. However, if an error should occur, we back all SCAN wood-burning 
stoves and inserts with an extensive, five-year limited warranty.

See also the 

General Instructions for Installation

 delivered with your 

stove for more details.

*  Height to the beginning of the flue pipe at top outlet
**  To the middle of the rear outlet (only SCAN 25 with firm base)
***Connection piece to fresh-air intake

Distances to flammable materials 

(mm) SCAN 25 with firm base:

Production number

Write the production number of your 
stove here so that you have it at hand 
in case you need to contact us.

**

SCAN 25/25-5

***

903

1

67

800

454

935

486

2

05

*

SCAN 25-5 with revolving 
base is 5 mm higher.

300

100

100

100

Distances to flammable materials: SCAN 25-5 with revolving base:

300

300

800 

800 

800

100

Middle position

Middle position

45

o

45

o

45

o

45

o

Important: SCAN 25-5 
with revolving base: all 
distances to flamma-
ble materials must be 
observed in all the pos-
sible positions of the 
stove. 

Technical info

Emission (% CO at 13% O2): 

     0.08%

Efficiency: 

     84%

Rated output: 

     6 kW

Chimney temperature: 

     215 oC

Flue outlet flow: 

     5.0 g/sec

Recommended low pressure in conn. piece:   15 Pa
Recommended fuel: 

     Wood  

Amount of fuel: 

     1,9 kg

Min./max. (information from the factory):       2-8 kW       
Weight, stove with convection:  

     100 kg 

Weight, stove with soap stone:  

     150 kg 

Connection piece, int. diameter: 

     135 mm 

Connection piece, ext. diameter: 

     148 mm