PDF User Manual

  1. Home
  2. Manuals
  3. Luxibel LX140 User Manual

Luxibel LX140 User Manual

Made by: Luxibel
Type: User Manual
Category: Flood Light
Pages: 11
Size: 0.39 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

LX140 

 

 

MAJSTRO LED PAR 18 X 8 W - RGBW LED 

 

USER MANUAL 

 

 

 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

 

 

 

terminator 

 

 

How to turn the controller line from 3-pins into 5-pins (plug and socket). 

 

 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

USER MANUAL 

1.

 

Introduction 

To all residents of the European Union 
Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle 
could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal 
waste; it should be taken to a specialized company for recycling. This device should be returned 
to your distributor or to a local recycling service. Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

Thank you for choosing Luxibel

®

! Please read the manual thoroughly before bringing this device into 

service. If the device was damaged in transit, do not install or use it and contact your dealer. 

2.

 

Safety Instructions 

 

Be very careful during the installation: touching live wires can cause life-threatening 
electroshocks. 

 

Always disconnect mains power when device not in use or when servicing or 
maintenance activities are performed. Handle the power cord by the plug only. 

 

Indoor use only.

 Keep this device away from rain, moisture, splashing and dripping 

liquids. Never put objects filled with liquids on top of or close to the device. 

 

Keep this device away from children and unauthorized users. 

 

Caution:

 device heats up during use. 

 

Do not stare directly at the light source

, as this may cause 

 

epileptic seizure in sensitive people 

 

temporarily loss of sight (flash blindness) 

 

permanent (irreversible) eye damage. 

 

There are no user-serviceable parts inside the device. Refer to an authorized dealer for 
service and/or spare parts. 

 

Respect a minimum distance of 0.5 m between the device’s light output and any 
illuminated surface. 

 

This is a Safety Class 1 device. It is therefore essential that the device be earthed. 
Have a qualified person carry out the electric connection. 

 

 

Make sure that the available voltage does not exceed the voltage stated in the specifications of this 
manual. 

 

Do not crimp the power cord and protect it against damage. Have an authorised dealer replace it if 
necessary. 

 

Use an appropriate safety cable to fix the device (e.g. VDLSC7N or VDLSC8N). 

 

Install the device at a minimal distance of 0.5 m from flammable and explosive objects or 
substances. 

 

The maximum ambient temperature is 40 °C. Do not operate the device at higher temperatures. 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

3.

 

General Guidelines 

Refer to the 

Velleman® Service and Quality Warranty 

on the last pages of this manual. 

 

 

Keep this device away from dust and extreme temperatures. Make sure the ventilation 
openings are clear at all times. For sufficient air circulation, leave at least 1" (± 2.5 cm) 
in front of the openings. 

 

Protect this device from shocks and abuse. Avoid brute force when operating the 
device. 

 

 

Familiarise yourself with the functions of the device before actually using it. Do not allow operation 

by unqualified people. Any damage that may occur will most probably be due to unprofessional use 
of the device. 

 

All modifications of the device are forbidden for safety reasons. Damage caused by user modifications 
to the device is not covered by the warranty. 

 

Only use the device for its intended purpose. All other uses may lead to short circuits, burns, 

electroshocks, lamp explosion, crash, etc. Using the device in an unauthorised way will void the 
warranty. 

 

Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and 
the dealer will not accept responsibility for any ensuing defects or problems. 

 

Mechanical wear and LEDs are not covered by warranty. 

 

A qualified technician should install and service this device. 

 

Do not switch the device on immediately after it has been exposed to changes in temperature. 
Protect the device against damage by leaving it switched off until it has reached room temperature. 

 

This device is designed for professional use on stage, in discos, theatres, etc. The device should only 
be used indoors with an alternating current of 100-240 V~, 50-60 Hz. 

 

Lighting effects are not designed for permanent operation: regular operation breaks will prolong their 
lives. 

 

Use the original packaging if the device is to be transported. 

 

Keep this manual for future reference. 

4.

 

Features 

The MAJSTRO LED PAR is an outdoor IP65 super-slim LED PARcan designed to be a powerful wash light 
for architectural lighting or outdoor events. It contains 18 x 8 W high-power RGBW LEDs with full control 
of colour saturation and temperature. A big innovation compared to traditional PARcans. 

 

 

IP65 rate for outdoor use 

 

18 x 8 W high-power RGBW LEDs  

 

DMX control via 4, 6 or 10 channels for simple or advanced controlling  

o

 

4-channel mode: RGBW 

o

 

6-channel mode: dimmer, RGBW, shutter 

o

 

10-channel mode: dimmer, RGBW, colour macro, shutter, auto programme, auto speed, 

dimmer speed 

 

built-in programmes with speed adjustment 

 

static colour selection 

 

master/slave mode for synchronized operation of multiple units linked in a chain 

 

flicker-free operation (400 Hz) 

 

clear LCD display for easy menu setting 

5.

 

Overview 

Refer to the illustrations on page 2 of this manual. 

 

LCD display with control panel 

 

XLR output 

XLR input 

 

power output 

power input 

 

mounting bracket 

 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

6.

 

Mounting and Connection 

Choose a suitable mounting spot. Mount the device in the desired angle using the included bracket. 
Connect the power cord to the mains. Disconnect after use. 

6.1

 

Mounting the Device 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable 
norms. 

 

The carrying construction must be able to support 10 times the weight of the device for 1 hour 
without deforming. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a 
qualified technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the 

installation material to be used… Have the material and the device itself checked regularly. Do not 
attempt to install the device yourself if you lack these qualifications as improper installation may 
result in injuries. 

 

For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the 
(folded) bracket. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 0.5 m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. All devices must be powered directly off a 
grounded switched circuit. Do not connect to a dimmer pack. 

 

The device has a power output to supply power to another device. When connecting several devices 

in a daisy chain via this output, make sure that the total current does not exceed the power line’s 
nominal current. Use power cables with an adequate section. 

 

The installation has to be approved by an expert before the device is taken into service. 

6.2

 

Connecting the Device 

Power 

Connect the device to the mains with the power plug. 
Power all devices directly off a grounded switched circuit. 
Do not connect the device to a rheostat or dimmer circuit, even when using the rheostat or dimmer 
channel solely for 0 % to 100 % switching. 

 

Have a qualified electrician carry out the electric connection. 

DMX-512 Connection 

 

When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the 

other side to the male XLR input of the device. Multiple devices can be linked through serial linking. 
The linking cable shall be a dual core, screened cable with XLR input and output connectors. 

 

A DMX terminator is recommended for installations where the DMX cable has to run a long distance 

or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the 
digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω 
resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in 
the chain. 

7.

 

Operation 

The device can be used in the following modes: 

 

stand-alone mode 

 

master/slave 

 

with a DMX-512 controller. 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

7.1

 

Control Panel 

Access the control panel functions using the four panel buttons located around the display. From left to 
right: 

 

Button 

Function 

MENU 

 

access the menu 

 

return to a previous menu option 

UP 

 

scroll through the menu options in ascending order 

 

increase value 

DOWN 

 

scroll through the menu options in descending order 

 

decrease value 

ENTER 

 

select menu option 

 

store the current menu or option within the menu 

 

Menu 

 

menu 

function 

description 

4-CH 

DMX channel mode 

selection of the DMX channel mode 

6-CH 

10CH 

C-- 

static colour 

static colour selection 
(1:R, 2:G, 3:B, 4:W, 5: GB, 6:RB, 
7:RG, 8:RGB, 9:RW, 10:GW, 11:BW, 
12:RGW, 13:RBW, 14:GBW, 15:RGBW) 

P-- 

auto programme 

selection of the auto programme with 
LED and motor speed setting 
(P1: 15-colour fading lo-hi-lo 
P2: 15-colour lo-hi 
P3:15-colour hi-lo 
P4:mixed colour switching 
P5:running P1-P4) 

S-- 

speed setting 

from slow to fast 

U-- 

colour setting mode 

 

dIM 

dimmer mode 

dimmer speed selection from fast 
(0.8 s) to middle (1.6 s) to slow (2.4 s) 

teMP 

fixture temperature 

 

PASS 

password 

to unlock, press UP-DOWN-UP-DOWN-
ENTER 

7.2

 

Stand-Alone Mode 

The device starts running in stand-alone mode after connection to the mains. This mode allows you to 
use the device without controller. 

1.

 

Connect the device to the mains to switch it on. 

2.

 

Press MENU to enter the menu. 

3.

 

Navigate to <C--> or <P--> with UP or DOWN and press ENTER to confirm. 

4.

 

Select an option with UP or DOWN and press ENTER to confirm. 

7.3

 

Master/Slave Mode 

Notes 

 

The master/slave mode allows for connecting several devices to a single master device in a daisy 
chain. 

 

All slave devices will then work synchronously with the master device. 

 

Configure all slave units before connecting the master unit to the daisy chain. 

 

The maximum number of slave units you can connect to a master unit is 18. 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

Slave units: 
1.

 

Connect the DMX input from your slave device to the DMX output of the previous device in the 
chain. 

2.

 

Connect the slave device to the mains to switch it on. 

3.

 

Repeat these steps for all slave units. 

Master unit 
1.

 

Connect the master device to the mains to switch it on. 

2.

 

Set the master unit to work in one of the running modes. 

3.

 

Connect the master unit as the first unit in the chain by connecting the DMX output of the master 
device to the DMX input of the first slave unit. 

7.4

 

DMX Mode 

The DMX mode allows you to control the device with any universal DMX controller. 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the 

signals. This digital start address is the channel number from which the device starts to “listen” to 
the DMX controller. The same starting address can be used for a whole group of devices or an 
individual address can be set for every device. 

 

When all devices have the same address, all the units will “listen” to the control signal on one 

particular channel. In other words: changing the settings of one channel will affect all devices 
simultaneously. If you set individual addresses, each device will “listen” to a separate channel 
number. Changing the settings of one channel will only affect the device in question. 

 

To set the device to work with a DMX controller: 

1.

 

Press MENU until <4-CH>, <6-CH> or <10-CH> is displayed and press ENTER. 

2.

 

Use UP and DOWN to set the DMX start address and press ENTER. 

Start addresses 

Use the table below to define the correct address. The table shows the settings for units 1 to 3. Apply the 
same principle for the other units. Example: 

 

Channel mode 

First unit 

Second unit 

Third unit 

Highest start address 

10 

start address 

11 (1 + 10) 

21 (11 + 10) 

503 

 

channel 

1 - 10 

11 - 20 

21 - 30 

 

 

DMX Channel Values 

 

4-channel Mode 

channel 

from 

to 

function 

description 

000 

255 

red 

from 0-100 % 

000 

255 

green 

from 0-100 % 

000 

255 

blue 

from 0-100 % 

000 

255 

white 

from 0-100 % 

 

6-channel Mode 

channel 

from 

to 

function 

description 

000 

255 

dimmer 

from 0-100 % 

000 

255 

red 

from 0-100 % 

000 

255 

green 

from 0-100 % 

000 

255 

blue 

from 0-100 % 

000 

255 

white 

from 0-100 % 

000 

010 

strobe 

no function 

011 

255 

from slow to fast 

 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

10-channel Mode 

channel 

from 

to 

function 

description 

000 

255 

dimmer 

from 0-100 % 

000 

255 

red 

from 0-100 % 

000 

255 

green 

from 0-100 % 

000 

255 

blue 

from 0-100 % 

000 

255 

white 

from 0-100 % 

000 

010 

colour macro 

white 

balance 

no function 

011 

030 

R 100 %, G 0-100 %, B 0 % 

031 

050 

R 100-0 %, G 100 %, B 0 % 

051 

070 

R 0 %, G 100 %, B 0-100 % 

071 

090 

R 0%, G 100-0 %, B 100 % 

091 

110 

R 0-100 %, G 0 %, B 100 % 

111 

130 

R 100 %, G 0 %, B 100-0 % 

131 

150 

R 100 %, G 0-100 %, B 0-100 % 

151 

170 

R 100-0 %, G 100-0 %, B 100 % 

171 

200 

R 100 %, G 100 %, B 100 %, W 100 % 

201 

205 

white 1 

206 

210 

white 2 

211 

215 

white 3 

216 

220 

white 4 

221 

225 

white 5 

226 

230 

white 6 

231 

235 

white 7 

236 

240 

white 8 

241 

245 

white 9 

246 

250 

white 10 

251 

255 

white 11 

000 

010 

strobe 

no function 

011 

255 

from slow to fast 

000 

051 

auto 

programmes 

no function 

052 

101 

auto programme 1 

102 

150 

auto programme 2 

153 

203 

auto programme 3 

204 

254 

auto programme 4 

255 

255 

auto programme 5 

000 

255 

auto speed 

only when auto programme is activated on channel 8 

10 

000 

051 

dimmer 

speed 

dimmer mode setting 

052 

101 

dimmer mode off 

102 

150 

dimmer mode 1 

153 

203 

dimmer mode 2 

204 

255 

dimmer mode 3 

8.

 

Cleaning and Maintenance 

 

All screws should be tightened and free of corrosion. 

 

The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, 
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in 
mounting supports, do not change the location of the connections… 

 

Mechanically moving parts must not show any signs of wear and tear. 

 

The electric power supply cables must not show any damage. Have a qualified technician maintain 
the device. 

 

Disconnect the device from the mains prior to maintenance activities. Let the device cool down. 

 

Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. 

 


background image

 

LX140 

V. 02 – 16/12/2014 

©Velleman nv 

 

Do not immerse the device in any liquid. 

 

There are no user-serviceable parts, apart from the fuse. 

 

Contact your dealer for spare parts if necessary. 

9.

 

Technical Specifications 

power supply 

100-240 V~, 50-60 Hz 

power consumption 

125 W 

light source 

18 x 8 W RGBW LEDs 

viewing angle 

30° 

beam angle 

15° 

IP rate 

IP65 

dimensions 

328 x 267 x 237 mm 

weight 

5.5 kg 

 

Use this device with original accessories only. Velleman nv cannot be held responsible in the 

event of damage or injury resulting from (incorrect) use of this device. For more info 
concerning this product and the latest version of this manual, please visit our website 
www.luxibel.com. The information in this manual is subject to change without prior notice. 

 

© COPYRIGHT NOTICE 

The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. 

No part 

of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise 
without the prior written consent of the copyright holder.  
 

 


background image

 

Velleman® Service and Quality Warranty 

Since its foundation in 1972, Velleman® acquired extensive experience in the electronics world 

and currently distributes its products in over 85 countries. 

All our products fulfil strict quality requirements and legal stipulations in the EU. In order to 

ensure the quality, our products regularly go through an extra quality check, both by an 

internal quality department and by specialized external organisations. If, all precautionary 

measures notwithstanding, problems should occur, please make appeal to our warranty (see 

guarantee conditions). 

General Warranty Conditions Concerning Consumer Products (for EU): 

• All consumer products are subject to a 24-month warranty on production flaws and defective 

material as from the original date of purchase. 
• Velleman® can decide to replace an article with an equivalent article, or to refund the retail 

value totally or partially when the complaint is valid and a free repair or replacement of the 

article is impossible, or if the expenses are out of proportion. 
You will be delivered a replacing article or a refund at the value of 100% of the purchase price 

in case of a flaw occurred in the first year after the date of purchase and delivery, or a 

replacing article at 50% of the purchase price or a refund at the value of 50% of the retail 

value in case of a flaw occurred in the second year after the date of purchase and delivery. 
• Not covered by warranty: 

- all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, 

falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), 

compensation for loss of profits; 

- consumable goods, parts or accessories that are subject to an aging process during normal 

use, such as batteries (rechargeable, non-rechargeable, built-in or replaceable), lamps, rubber 

parts, drive belts... (unlimited list); 
- flaws resulting from fire, water damage, lightning, accident, natural disaster, etc.…; 

- flaws caused deliberately, negligently or resulting from improper handling, negligent 

maintenance, abusive use or use contrary to the manufacturer’s instructions; 
- damage caused by a commercial, professional or collective use of the article (the warranty 

validity will be reduced to six (6) months when the article is used professionally); 
- damage resulting from an inappropriate packing and shipping of the article; 
- all damage caused by modification, repair or alteration performed by a third party without 

written permission by Velleman®. 
• Articles to be repaired must be delivered to your Velleman® dealer, solidly packed 

(preferably in the original packaging), and be completed with the original receipt of purchase 

and a clear flaw description. 
• Hint: In order to save on cost and time, please reread the manual and check if the flaw is 

caused by obvious causes prior to presenting the article for repair. Note that returning a non-

defective article can also involve handling costs. 
• Repairs occurring after warranty expiration are subject to shipping costs. 

• The above conditions are without prejudice to all commercial warranties. 
The above enumeration is subject to modification according to the article 

(see article’s manual). 

 

 

 
 
 
 
 

Made in PRC 

Imported by Velleman nv 

Legen Heirweg 33, 9890 Gavere, Belgium 

www.velleman.eu