Door Access Control with the VoIP interface 

 

Release 1.4 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

 

 

 

 

IP Door Phones 

IP39-4X 

Quick Installation Guide 

 

 

 

 

 

 

 

 

 

 

Document Release: 1.04 

Release Date: 18-Jun-15 

 

 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

 

NOTICE 

This document refers to the Nista Devices GmbH Door Access Control devices with VoIP protocol capabilities. 
Additional copies of this manual may be obtained from Nista Devices GmbH. Reproduction of this manual or parts thereof without written 
permission from Nista Devices GmbH is strictly prohibited. 
Nista Devices GmbH reserves the right to modify the hardware and software described herein without prior notice. However, changes made to the 
hardware or software described do not necessarily render this publication invalid.   

 

 

 

 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

 

 

Table of Contents 

1

 

Introduction ................................................................................................................................................................ 5

 

1.1

 

List of Available Models .................................................................................................................................... 5

 

2

 

The IP Door Phone kit contents ................................................................................................................................. 5

 

3

 

Installation .................................................................................................................................................................. 6

 

3.1

 

Physical installation ........................................................................................................................................... 6

 

3.2

 

IP Door Phone installation ................................................................................................................................. 6

 

4

 

Access to WEB Programming ................................................................................................................................... 9

 

5

 

Reset device to Factory Default Configuration ........................................................................................................ 15

 

 

 

 

 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

 

1 Introduction 

 

  

 

To avoid damage to the Door Phone, the external power supply and POE 

Ethernet connection should be disconnected from mains prior to 

connecting wires to the Door Phone unit. 

The External Power Supply does not included in standard IP394X 

package 

1.1  

 List of Available Models 

Model 

Description 

IP39-40PC 

IP Door Phone, Piezo Keypad, Integrated Internal Video Camera 

IP39-40P 

IP Door Phone, Piezo Keypad 

IP39-41PC 

IP Door Phone, Piezo Single Button, Integrated Internal Video Camera 

IP39-41P 

IP Door Phone, Piezo Single Button 

IP39-40AC 

IP Door Phone, Touch Keypad, Integrated Internal Video Camera 

IP39-40A 

IP Door Phone, Touch Keypad 

IP39-41AC 

IP Door Phone, Touch Single Button, Integrated Internal Video Camera 

IP39-41A 

IP Door Phone, Touch Single Button 

 

2 The IP Door Phone kit contents 

 

IP394X Package content:

 

 

IP Door phone unit 

 

Rear metal cover 

 

Rear rubber mat 

 

Set of terminal connectors 

 

Hex key wrench for security screw  

 

Note

1.  Device is optionally available for orders with the internal wide-angle digital video camera. 

The Video camera must be order separately. 

2.  Allowed to use External Power Supply if a customer

’s LAN doesn’t support POE ( Power Over Ethernet) 

functionality. External Power Supply shall respond to follow technical requirements: 

 

Input: 100 

– 240 V AC 

 

Output: 5V DC; 2A 

 

5V DC Power supply output shall be connected to IP Door Phone in accordance with  required pins 
polarity 

3.  The External Power Supply does not included in standard IP394X package 

 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

3 Installation 

 

3.1 

Physical installation

 

The Door phone can be mounted on the wall by using installation bracket provided with the unit. 

 

To install the IP Door Phone Unit on the wall: 

 

Open the   IP Door Phone case by rotating the secret screw from the bottom side of the unit. 
 

 

Figure 3-1 Door Phone wall installation 

To install the wall bracket: 

1.  Measure and mark the location of the holes on the wall, where they are to be drilled. 

2.  Drill the holes and insert the wall dowels into the holes.  

3.  Place the rubber membrane on the wall and then metal unit base using the provided wall screws.( See Figure 3-1) 

4.  Connect all required wired connections 

5.  Put the 

Door Phone’s front panel into the base latch mechanism, then close the case and lock with the any tamper  

screw.  

 

 

3.2 

IP Door Phone installation 

 

The   IP Door Phone can be installed as an individual access control device.  

Figure 3-2 shows the terminal locations on the wire connector provided with the unit. This connector is then inserted 
into the mating connector located at the base of the internal PCB. All wiring to the unit shall be attached to the wire 
connector. 

The Ethernet RJ-45 socket is for the LAN network cable and PoE connection. 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

The wiring connector has screw connector type terminals. In order to attach a wire, you must insert the stripped end of 
the wire into the appropriate wiring connector socket and tighten the terminal screw. This will bring together the wire 
connection. 

  

 

To avoid damage to the Door Phone, the external power supply ( id used 

) or POE Ethernet should be disconnected from mains prior to connecting 

wires to the Door Phone unit. 

The External Power Supply does not included in standard IP394X 

package 

 

 

Figure 3-2The IP Door Phone PCB Module 

1.  Remove the front panel cover from the Door Phone unit and find the wiring connector on the PCB module. ( See 

Figure 3-2 ) 

2.  Connect the door-lock relay wires to 

“Relay 1”

  / 

“Relay 2”

 terminals.  

 

Note

1.  Draw attention on NO/NC 

jumper position. The closed ‘Center’ Pin +’NO’ pin means the ‘Normally open’ 

relays st

atus in powered mode. The closed ‘Center’ Pin +’NC’ pin means the ‘Normally Close’ relays 

status in powered mode 

2. 

Important: 

To set device in operational mode, switch 1 on PCB shall be switched to 

position 

“Normal”. 

( See Figure 3-2 ) 

 

3.  If an external switch button is used ( See Web GUI Door Functions -> Sensor  -Chapter  

Error! Reference 

ource not found.

), connect the button wires to the 

“Sensor 2”

 and the 

“Sensor 1”

 terminals.  

4.  Plug the wiring connector to the Door Phone PCB module.  

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

5.  Attach the Door phone into the installation bracket.

 

 

6.  Check the LAN network cable is inserted into the 

Ethernet

’ RJ-45 socket and that if PoE is deployed the unit 

powers up. 

7.  If an external power supply is used , switch on the external power supply pins DC5V.  

 

 

Note

1.  The 

IP Door Phone internal relay’s maximum supported electrical current is 2A  

2. 

Important: 

To set device in operational mode, switch 1 on PCB shall be switched to position 

“Normal”. 

See Figure 3-2 )

 

 

Connector’s PINs  

Description 

1 ( SW2) 

Factory Default Settings switch: 

‘Normal’ – Door Phone normal working position 

‘Default’ – Set to default procedure mode 

Hardware Reset ( Cold Reset Switch) 

3 ( NO/NC Jumper) 

Relay 1 and Relay 2 Normally Open and Normally Close status jumper. 

Closed Central Pin (2) + ’NO’- (1) pin means the ‘Normally open’ mode. 

Closed Central Pin (2) + ’NC’ - (3) pin means the ‘Normally Close’ mode 

Note: Relay 2 works in Normally Open (NO) mode only 

Microphone Connector 

Speaker Connector 

6- Ethernet 

POE/LAN connection 

5VD (5V DC)

 

External power supply 5VDC 2A input (if no POE applied). 

Draw attention on connection polarity: +5V and GND marked on PCB 

(Figure 3-2) 

The External Power Supply does not included in standard IP394X package 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

Connector’s PINs  

Description 

SEN 1/2 (Sensor 1/2*) 

Door status detector. 

Also can be used as external Switch button connection (Chapter 

Error! 

eference source not found.

). Note: The short circuit closer type External 

Switch button can be used for manual door opening 

REL 1/2 (Relay 1/2) 

Support 30VDC 2A 

Internal relays Normally Open and Normally Close status depends on JP1 

jumper position. 

Audio Out*

 

Reserved for future release 

 

Note: * - Listed feature support depends on   IP Door phone firmware release 

 

Figure 3-3 IP394X Connections  

Note: 

The door electrical Lock requires separate powering follow by door lock manufacture’s requirements 

 

 

4 Access to WEB Programming 

1.  The unit comes configured with the default IP address: 

10.10.10.6 . 

To access to the unit’s WEB programming if 

your LAN configured with different subnet please make following: 

2.  On Windows 7 PC: 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

10 

 

Go to Control Panel 

 

Open ‘Network and Sharing Center’ 

 

       

 

 

Click on ‘Change adapter settings’ 

 

         

 

 

 

 

 

 

         

 

 

Mouse right click on active Ethernet connection and chose ‘Properties’ 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

11 

 

 

 

In LAN properties window select ‘Internet Protocol Version 4 (TCP/IPv4) option and click on 
‘Properties’ button 

         

    

 

Select 'Use the following IP address:' and insert IP Address and Subnet mask as shown on the 
picture below 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

12 

 

 

 

Press ‘OK’ to accept settings  
  

3.       Launch Internet browser and type 10.10.10.6 in address bar. 

 

4.  Log in to the Nista web GUI using the a

ppropriate user’s credentials 

IP 394X provides different management levels for WEB-Management: Administrator and User 

 

‘Administrator’ level has access to all IP394X configuration parameters 

 

‘User’ level has limited access to IP394X configuration parameters. 

Fill Administrator or User login name and Password fields. 

  

 

 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

13 

Note: 

1.  The default IP Door Phone IP address is 

10.10.10.6 

and it is 

configured as ‘Static’ IP Address. 

2.  The default web-programming Administrator credentials are: 

 

User name: ‘

admin

’ 

– For Administrator management level and

 

‘user’ 

– for User management level  

 

Default Password: 

1234 

for both management levels  

3.  It is strongly recommended to change the default administrator password to a stronger one. Allowed Password 

characters: Up to 19 Digits: 0-9, Aa-Zz, no space allowed 

4. 

Also IP Door phone IP address could be seen on the unit’s LED display (keypad models only). 

Dial: P/

 + 1 + Web Access Administrator password + # 

 

             

 

5. 

Go to ‘Network’ then click on ‘LAN' and configure IP394X network parameters 

6. 

Press Apply button and then ‘Save & Reboot ‘ menu option 

 

7.  Return to Windows 7 PC Network adapter properties and set IP address and Subnet mask to the original 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

14 

 

       

 

  

 

Configure the rest of parameters by using the IP Door Phone Use

r’s manual document 

 

 

 

 


background image

 

 

NISTA DEVICES GmbH 2013 

© All Rights Reserved 

 

15 

5 Reset device to Factory Default 

Configuration 

IP Door phone can be reset to its Factory default configuration by using following actions: 

1.  Via WEB-Management interface ( See Chapter 7.8 in User Manual document) 

2.  By using the 

hardware ‘Factory Default Settings’ switch ( See Figure 3-2 ) 

To set IP Door Phone to Factory Default Setting by using 

hardware ‘Factory Default Settings’ switch: 

 

Power off the device. 

 

Put the switch to “DEFAULT” position. 

 

Power on this device will restore the factory default.  

o

 

LED Display can show the message “ Destination not set “ if Day or Night destinations not specified 
and 

device’s case is open 

o

 

LED Display Show

s’ Set to default’ message if a case is closed  

o

 

 

 

Power off the device. 

 

Put the switch back to “NORMAL” position 

 

Power on the device 
 

 

Figure 5-1 Factory Default Settings switch SW2