PDF User Manual

  1. Home
  2. Manuals
  3. RIB PRINCE 24V Operator's Manual

RIB PRINCE 24V Operator's Manual

Made by: RIB
Type: Operator's Manual
Category: Gate Opener
Pages: 13
Size: 0.8 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

ITALIANO pag. 05 / FRANÇAIS pag. 16 / ENGLISH page 27 / DEUTSCH pag. 37 / ESPAÑOL pag. 48

PRINCE 24V

Operatore

Operateur

Operator

Torantrieb

Operador

Alimentazione

Alimentation

Power Supply

Stromspannung

Alimentacion

codice

code

code

code

codigo

PRINCE 24V

230V 50/60Hz

120V 60Hz

AA14031

a richiesta/on request

Peso max anta

Poids maxi battant

Max leaf weight

Max. Torgewicht

Peso max hoja

250 kg / 550 lbs

Spinta

Poussée

Thrust

Schubkraft

Empuje

100 kg / 220 lbs

Spinta max

Poussée maxi

Max thrust

Max Schubkraft

Empuje max.

140 kg / 309 lbs

OPERATORE PER CANCELLI A BATTENTE
OPÉRATEUR POUR PORTAILS À BATTANT 
OPERATOR FOR LEAF GATES
TORANTRIEB FÜR FLÜGELTORE 
OPERADOR PARA CANCELAS DE BATIENTE

T2 24V

con / avec / with / mit

Brevettato - Patented 
N. 1 503 019 - US 7,000,353 B2

 


background image

27

27

G

B

SYSTEM LAY-OUT

1 - PRINCE 24V operator

2 - Tuned aerial

3 - Flashing lamp

4 - Key selector

5 - Photoelectric cells (external)

T

ECHNICAL FEATURES

PRINCE 24V is a linear operator designed for swing gates long 

up to 2 m and weight up to 250 kg (Pic. 1).

PRINCE  24V  works  without  electric  limit  switches,  but  with 

mechanical stoppers.

N.B.:  It  is  advisable  to  fit  an  electrical  lock  to  ensure  an 

efficient gate locking.

TECHNICAL

DATA

Max. leaf length
Max. leaf weight
Max. travel
Average opening time
Operating speed
Power supply
Nominal Motor capacity
Max Motor capacity (blocked)
Nominal Power absorbed
Max Power absorbed (blocked)
Nominal Thrust force
Max Thrust force (blocked)
Normative cycles
Daily operations suggested
Service
Guaranteed consecutive cycles
Weight of the PRINCE 24V  
Noise
Operating Temperature
Protection grade

m. 

2

kg 

250

mm 

343**

s. 

14

m/s. 

0,0134

 

24Vdc

12

89

0,88

3,72

1000

1500

n° 

∞ - 14s/2s

n° 

60

80%

n° 

60/14s

kg 

5

db 

<70

°C 

-30 ÷ +55°C

IP 

44

PRINCE 24V

1

2

Measurements in mm

**  With incorporated mechanical stopper that cuts out during opening. 

If the mechanical stopper is used also during the closing (optional), 

the maximum stroke is reduced by 30 mm.

1

5

5

4

4

3

2

1

 


background image

28

28

INSTALLATION PRINCE

G

B

COMMAND TYPE 

USE OF THE SHUTTER

 

Skilled persons 

Skilled persons 

Unrestricted use

 

(out of public area) 

(public area) 

 

with manned operation 

non possibile

with visible impulses 

C or E 

C or E 

C and D, or E

(e.g. sensor) 

with not visible impulses

 

C or E 

C and D, or E  C and D, or E

(e.g. remote controldevice)

automatic 

C and D, or E 

C and D, or E  C and D, or E

A: Command button with manned operation, like code ACG2013

B:   Key selector with manned operation, (gate operating as long as the button is held 

pressed) like code ACG1010.

C: Adjustable power of the motor.

D:  Safety  edges  to  keep  thrust  force  within  the  limits  of  EN12453  regulation  - 

Appendix A.

E:  Photocells, like code ACG8026 (to install every 60÷70 cm from top to bottom of 

the gate ,to a maximum of 2,5 m - EN 12445 point 7.3.2.1)

Parts to install to comply  EN 12453 standard COMMAND TYPE

P

RE-INSTALLATION CHECK LIST

The gate leaves must be firmly fixed to the hinges on the gate pillars, they 

must not flex during the movement and they must swing without any friction.

Before installing the operator, make sure you have enough room to fix the 

operator on the pillar.

In case the gate is like the one depicted in Pic. 1, there is no need for any 

modification.

Gate features and installation must comply with local regulations and 

standards.

The gate can be automated only if it is in good conditions and complies with 

EN12604 norms.

The gate leaf must not have a pedestrian doors in its frame. Should there 

be a pedestrian opening, take the appropriate steps according to EN12435 

norms (e.g. cutting out the motor when the pedestrian door is opened by 

fixing a safety micro switch connected to the control board).

Make  sure  not  to  create  any  trapping  points  or  areas  (e.g.  with  the  gate 

completely opened, between any opening in the gate frame and the side 

wall).

E

MERGENCY MANUAL RELEASE

This applies only if the unit is not equipped with back-up batteries. In case 

of  a  black-out,  the  gate  can  be  pulled  open  after  the  operator  has  been 

unlocked with the emergency key  provided (rotate the key by 90° clockwise, 

Pic. 3).

Caution

In order to be able to manually open the gate leaf make sure of the following:

-  The gate leaves must be endowed with appropriate handles;

-  Position of the handles onto the gate leaves must be in risk free area;

-  The manual force necessary to move the gate leaves should not be higher 

than 225 N, in case of installations at domestic/private dwellings, and 390N 

in case of installations in business premises (according to points 5.3.5 of 

the EN12453 norm).

Note:

  in case of an installation with an overlapping two leave swing gate 

to ensure a safe/proper locking a mechanical bolt must be installed 

along with an electric lock. The mechanical bolt (ACG5000) must be 

installed at the bottom of the first gate leaf to close so that it will be 

simply operated by the pressure of the second gate leaf. The electric 

lock will simply latch one gate leaf to the other. 

F

IXING THE ACTUATOR ATTACHMENT TO THE COLUMN

To obtain a correct movement of the gate leaf, it is necessary to comply with 

the measurements given. 

In case an iron pillar is available, weld the bracket straight to it.

In case you need to fix the bracket onto a concrete pillar, use the fixing plate 

as shown in picture 4, that will have to be fastened with 4 Fischer screws 

of  Ø 8 mm.

In case you have a wall parallel to gate leaves when in open position, you 

must allow for a niche in which the operator can fit in. 

F

IXING THE ACTUATOR ATTACHMENT TO THE GATE

Weld the second bracket to the gate (pictures 5,6)

During installation make sure to comply with the measurements mentioned 

in the table below. 

Fix  the  PRINCE  and  try  several  times  to  open  and  to  close  the  gate, 

controlling that the cover does not touch the moving gate.

3

5

6

4

 


background image

29

29

G

B

In  order  to  carry  out  a  proper 

installation  of  the  operator,  it  is 

necessary  to  comply  with  the 

geometry  measurement  shown  in 

the tables below.

S1

Z

Y

X

S2

  Z

 

X

S3

  Z 

X

COL 

Column attachment

7

If the pillar is too large, and it is not possible to adjust 

the  actuator  complying  the  measurements  (B),  you 

must make a niche in the pillar or you have to move the 

gate closer to the edge of the pillar.

ANT 

Leaf attachment

Respect the measures for a correct installation

1÷2

90°

L

Min.÷Max

α

A

max

T

sec

COL ANT

  B 

D  E

110°

  0 

100 

100 

765 

90 

13,5 

S2-X 

A

  20 

100 

100 

765 

90 

13,5 

S2-Y 

A

  40 

100 

100 

765 

90 

13,5 

S3-X 

A

  60 

110 

100 

765 

90 

14 

S3-Y 

A

  80 

140 

110 

765 

115 

17 

S3-X 

B

  100 

160 

110 

765 

115 

18 

S3-X 

B

  120 

180 

110 

765 

115 

19,5 

S3-X 

B

  140 

210 

110 

765 

115 

21,5 

S1-Z 

B

  150 

220 

120 

765 

115 

23 

S1-Z 

B

 

 

 

  20 

110 

140 

765 

90 

17 

S1-Y 

A

Measures WITH 2 MECHANICAL STOPPERS

110°

90°

L

Min.÷Max

α

A

max

T

sec

  B 

D  E

1÷2

COL ANT

  0 

100 

100 

730 

90 

13,5 

S2-X 

  20 

100 

100 

730 

90 

13,5 

 S2-X  

A

  40 

100 

100 

730 

90 

13,5 

S3-X 

A

  60 

110 

100 

730 

90 

14 

S3-X 

A

  80 

140 

110 

730 

115 

17 

S3-X 

B

  100 

160 

110 

730 

115 

18 

S3-X 

B

  110 

180 

120 

730 

115 

20 

S1-Z 

B

 

 

 

 

 

  20 

100 

140 

730 

90 

16 

S2-Y 

A

B

A

 


background image

30

30

G

B

M

ECHANICAL STOPPER - OPTIONAL 

(Code ACG8088)

Optional mechanical stopper to stop the closing, if the gate is not fitted with 

a floor stopper.

M

ECHANICAL STOPPER ADJUSTMENT 

To adjust the stoppers you have to follow the scheme (Pic. 9).

To set the opening limit it is enough to fix the stopper (A) in the needed 

position  by tightening the 8mA screw with a n. 13 key.

To  obtain  the  desired  closing  limit  you  must  adjust  the  stopper  (B) 

(OPTIONAL) in the needed position and tighten it as for stopper (A).

M

AINTENANCE

Maintenance should be carried out by skilled and qualified staff only, after 

switching off the mains supply.

Regularly  lubricate  the  hinges  of  the  gate  every  6  months  and  keep  the 

thrust needed to move the gate leaf monitored (according to EN12453).

8

9

ELECTRIC CONNECTIONS

A

B

C

D

 


background image

31

31

G

B

ANTENNA

ANTENNA
BRAIDING

CLOSE

OPEN

STOP

FUSE
T 2 A

PHOTOCELLS

STEP BY STEP

COMMON

COMMON

24Vdc 0,8A ± 15% for ACCESSORY SUPPLY

24Vdc 0,8A ± 15% for AUTOTEST SAFETY STRIPS

BLINKER

24Vdc 20W

LED

R=2,2K 1/4W

ELECTRIC

LOCK

PEDESTRIAN

SAFETY STRIPS

POWER SUPPLY

230Vac 50 Hz

TRANSFORMER

M1

M2

T2 24V 

code BC07088

T2 24V CRX  code BC07089

 


background image

G

B

B

 - SETTINGS

DIP 1 

(ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)

DIP 2 

(ON) - TIMER (POINT D)

DIP 3 

 

(ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND TOTAL OPENING 

AND CLOSING (AS PER THE IMPACT TESTS OF EN12453) 

DIP 1-2 

 

MEMORIZATION/CANCELLATION  OF  RADIO  CONTROL  CODES  FOR  TOTAL  OPENING  (ONLY 

MODEL CRX) (POINT E)

DIP 1-3 

 

MEMORIZATION/CANCELLATION  OF  RADIO  CONTROL  CODES  FOR  PEDESTRIAN  OPENING 

(ONLY MODEL CRX) (POINT F)

DIP 2-1 

 

MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER

DIP 4

 

 Photocells always active (OFF) - Photocells active only during closing (ON)

DIP 5

 

Pre-blinking (ON) - Normal blinking (OFF)

DIP 6

 

 Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic (ON)

DIP 7

 

 Power sensor operation (ON-activated) time operation (OFF-activated).

DIP 8

 

Electric lock activation (ON-activated)

DIP 9

 

Electric lock pulse release (ON-activated)

DIP 10

  Electric lock pulse engagement (ON-activated)

DIP 11

  Easy release activation (ON-activated)

DIP 12

  Sensor TEST activation (ON-activated).

DIP 13

  Selection of 1 or 2 motor operation (default OFF 2 motors)

DIP 14   OFF

DIP 15   OFF

DIP 16 

 

IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS

ON 

ACTIVATED

OFF 

DEACTIVATED

JP1 =>

  Check that the jumper is inserted!

JP2 =>

  Check that the jumper is inserted!

JP3 => 

Check that the jumper is inserted!

PROG =>

  S3 Programming button

ADJUSTMENTS

ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL THE PROGRAMMING 

PROCEDURES.

NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.

THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO WITHIN 5 SECONDS AS 

PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC FORCE), THEREBY COMPLYING WITH THE 

IMPACT TESTS ALSO OUTLINED BY EN12453). 

IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY POSITION DIP 3 TO 

OFF. IN THIS CASE THE GATES STOP WITHOUT REVERSING.

RUN TRIMMER (TR1) high-speed electronic regulator

This trimmer permits motor speed adjustment (the default setting is maximum speed). Adjustment of the automation 

is useful for compliance with European impact standards.

LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control

The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes the voltage output 

across the motor(s) (turning it clockwise increases the speed). Adjustment is performed to determine the correct 

speed at the end of opening and closing according to the gate or when there is friction that might cause the system 

to function poorly.

AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT ACTIVATED and LED 

DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)

This trimmer makes it possible to adjust the time for total or pedestrian automatic closing. Only with gate completely 

(total) or partially (pedestrian) open and LED DL6 on (trimmer rotated clockwise). 

The pause time can be adjusted from a minimum of two seconds up to a maximum of two minutes.

LED SIGNALS

DL1  program activated (red)

DL2  gate opening M2 (green)

DL3  gate closing M2 (red)

Power supply 230 Vac 50/60 Hz - external to the control 

panel - (120V/60Hz upon request)

Common contact

Closing impulse contact (NA)

Opening impulse contact (NA)

STOP impulse contact (NC)

Radio Antenna

Gate open state and battery state output indicator (24Vdc 

3W max)

+ 24Vdc safety strip self-test power supply

Safety strip contact (NC)

Common contact

Photocells contact (NC)

Single pulse contact (NO)

Pedestrian opening contact (NA)

+ 24Vdc accessories power supply

- 24Vdc accessories power supply

Electric lock connection (MAX 15W 12V)

- 24Vdc blinker (code ACG7061) power supply. 

Pay 

attention to the polarity.

Connection to secondary coil of transformer 18 Vac

MOTOR 1 CONNECTION (without polarity)

MOTOR 2 CONNECTION (without polarity)

Connector dedicated to the factory programming. 

DO NOT REMOVE ANY JUMPER!

OTHERWISE THE OPERATOR WILL NOT WORK!

Connector dedicated to the factory programming (only CRX 

control board)

DO NOT REMOVE ANY JUMPER!

OTHERWISE THE OPERATOR WILL NOT WORK!

Built-in radio module (model CRX), or connector for radio 

receiver RIB, 24 Vdc supply

Connector for charge card of 24Vdc battery (code 

ACG4648)

Trimmer for high speed adjustment operations

Trimmer for low speed adjustment operations

Trimmer for automatic closing time adjustment (DISABLED 

DEFAULT AND DL6 LED OFF)

Programming button

Motor protection fuse

Transformer protection fuse

TRANSFORMER

J1

J2

J3

J4

J5

J6

J7

J8

J9

J10

TR1

TR2

TR3

S3

FUSE 1

F1

N F

COM.

CLOSE

OPEN

STOP

AERIAL

SIGNAL

A+TEST

EDGE N.C.

COM.

PHOTO N.C.

K BUTT.

PED. BUTT.

A+

A -

LOCK

SECONDARY

TRANSFORMER

MOTOR 1

MOTOR 2

SW T2 24V

SW RADIO

RADIO

BATTERY

CHARGER

TRIMMER RUN

TRIMMER LOW SPEED

TRIMMER TCA

PROG

T 8 A

T 2 A

J3

TR2

TR1

J2

J4

F1

FUSE 1

J5

J6

TR3

J10

J8

J9

J1

J7

S3

A - 

CONTROL PANEL FEATURES

 


background image

G

B

DL4  gate opening M1 (green)

DL5  gate closing M1 (red)

DL6  automatic closing indicator (red)

DL7  photocell contact (NC) (red)

DL8  sensor contact (NC) (red)

DL9  STOP button (NC) (red)

DL10  radio code program (green)

FUSES

Fuse 1 T 8A

  MOTOR PROTECTION FUSE

F1 T 2A

 

 TRANSFORMER PROTECTION FUSE (on the outside of the T2 24V board)

C

 -  MOTOR ROTATIONAL DIRECTION CONTROL

1 -  Set DIP 1 to ON => LED DL1 starts flashing.

2 -  Press and hold the PROG button. (movement is now manually controlled - open-stop-close-stop-open - etc.) => 

GREEN LEDS DL2 and DL4 are lit and the gate panels open with a fixed lag of 2 sec. If they close instead of 

open, release the button and reverse the two wires on the motor used.

3 -  After opening release the PROG button and calibrate the mechanical opening stops (on the operator).

4 -  Press and hold the PROG button => RED LEDs DL3 and DL5 turn on and the gate panels close with a time 

lag of 2 sec. 

5 -  Continue to hold the PROG button until the gate is completely closed.

6 -  Leave the two doors completely closed to set the timer.

7 -  Reset DIP1 to OFF => LED DL1 turns off, signaling exit from control.

N.B.: During this check the stop, the photocells and the sensors are not active.

D

 -  SETTING THE TIMER FOR 2 MOTORS (#) WITH POWER SENSOR ACTIVATED (DIP 7 ON)

WHILE SETTING THE TIMER THE POWER SENSOR IS CONTINUOUSLY ACTIVATED.

1 - The gate must be completely closed.

2 - Set DIP 2 to ON => LED DL1 will blink rapidly.

3 - Press the PROG button. => M1 opens.

4 -  When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops M1 (memorizing the 

time and the power) => At the same time M2 is triggered to open.

5 -  When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops M2 (memorizing the 

time and the power). 

6 -  Press the PROG button. => M2 closes.

7 -  Press the PROG button. => M1 closes and sets the lag time between M2 and M1. At the same time LED DL1 

stops flashing indicating exit from the programming procedure.

   Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

8 -  The gate panels will close in high-speed mode (depending on how you set the RUN trimmer) and near total closure 

in the slow mode (depending on how you set the LOW-SPEED trimmer).

9 -   Upon closing the power sensors stop the gate.

10 - AFTER PROGRAMMING RESET DIP 2 TO OFF.

D

 -  SETTING THE TIME FOR ONE MOTOR (M1) (#) WITH POWER SENSOR ACTIVATED (DIP 7 ON)

CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST BE POSITIONED TO ON; DURING PROGRAMMING THE 

POWER SENSOR IS CONTINUOUSLY ACTIVE.

The gate must be completely closed.

1 -  Set DIP 2 to ON => LED DL1 will blink rapidly.

2 -  Press the PROG button. => M1 opens.

   When the mechanical opening stop is reached, the AUTOMATIC POWER SENSOR stops M1 (memorizing the 

time and the power). 

3 -  Press the PROG button. => M1 closes.

   At the same time LED DL1 stops flashing indicating exit from programming. Safety and other gate commands 

now operate normally (inversions, stop, alarms, etc.).

   Upon closing the power sensor stops the gate.

4 - 

AFTER PROGRAMMING RESET DIP 2 TO OFF.

(#)  DURING  PROGRAMMING  THE  SAFETY  DEVICES  ARE  ACTIVE  AND  STOP  THE  PROGRAMMING 

PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT). TO REPEAT PROGRAMMING SET DIP 2 

TO OFF, CLOSE THE GATE USING THE PROCEDURE “MOTOR ROTATIONAL DIRECTION CONTROL” AND 

REPEAT THE DESIRED PROGRAMMING PROCEDURE.

D

 -  SETTING THE TIME FOR 2 MOTORS (#) WITH TIME OPERATION (DIP 7 OFF)

1 -  The gate must be completely closed.

2 -  Set DIP 2 to ON => LED DL1 will blink rapidly.

3 -  Press the PROG button. => M1 opens.

4 -  When the mechanical opening stop is reached, wait a second then press the PROG button => M1 stops and 

M2 opens.

5 -  When the mechanical opening stop is reached => wait 1 second and press the PROG button => M2 stops.

6 -  Press the PROG button => M2 closes.

7 -  Press the PROG button => M1 closes setting the time lag between M2 and M1.

   At the same time LED DL1 stops flashing indicating exit from the programming procedure.

   Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

8 -  After the set amount of time, the gate will stop.

9 -  

AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.

NOTE:

 The slowdown is automatically determined by the control board during the time setting phase and is activated 

at about 50 to 60 cm before reaching the mechanical opening or closing limit.

D

 -  SETTING THE TIME FOR 1 MOTOR (#) WITH TIME OPERATION (DIP 7 OFF)  

CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON

1 -  The gate must be completely closed.

2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.

3 - Press the PROG button => M1 opens.

4 -  When the mechanical opening stop is reached, wait a second then press the PROG button => M1 stops.

5 -  Press the PROG button => M1 closes.

   At the same time LED DL1 stops flashing indicating exit from the programming procedure.

   Safety and other gate commands now operate normally (inversions, stop, alarms, etc.).

6 -  After the set amount of time, the gate will stop.

7 - 

AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.

D

 -  SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME AND POWER SENSOR OPERATION

With gate closed:

1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON ( LED DL1 flashes slowly).

2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.

3 - Push the pedestrian button to stop movement (thereby setting M1 opening).

4 - Push the pedestrian button to start closing.

5 - Upon closing reset DIP 1 and 2 to OFF.

(#)  DURING  PROGRAMMING  THE  SAFETY  DEVICES  ARE  ACTIVE  AND  STOP  THE  PROGRAMMING 

PROCEDURE (LED DL1 FROM FLASHING BECOMES CONSTANT). 

TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING THE PROCEDURE “MOTOR 

ROTATIONAL DIRECTION CONTROL” AND REPEAT THE DESIRED PROGRAMMING PROCEDURE.

E

 -  RADIO CODE PROGRAMMING FOR TOTAL OPENING

(UP TO 62 CODES - CRX MODELS ONLY)

Programming can be done only when the gate is stationary.

1 -  First set DIP 1 to ON and then DIP 2 to ON.

2 -  The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.

3 -  Press the remote control button (usually channel A) within the allotted 10 seconds. If the remote is memorized 

properly LED DL10 (green) blinks.

4 -  The programming time for codes is automatically renewed in order to memorize the next remote control.

5 -  To finish programming, wait 10 seconds, or press the PROG button briefly. The red LED DL1 stops flashing.

6 -  Reset DIP 1 to OFF and DIP 2 to OFF.

7 -  End of procedure.

CANCELLATION OF ALL RADIO CODES FOR TOTAL OPENING

Cancellations can only be performed when gate is stationary.

1 -  Set DIP 1 to ON and then DIP 2 to ON.

2 -  The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.

3 -  Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two flashes of green LED 

DL10.

4 -  The red LED DL1 remains active and you can add new codes as shown above.

5 -  Reset DIP 1 to OFF and DIP 2 to OFF.

6 -  End of procedure.

INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING

Indication only when gate is stationary.

1 -  Set DIP 1 to ON and then DIP 2 to ON.

2 -  The green LED DL10 flashes 6 times when the memory is full (62 codes).

3 -  LED DL1 will then remain active for 10 seconds enabling possible cancellation of codes.

4 -  Reset DIP 1 to OFF and DIP 2 to OFF.

5 -  End of procedure.

F

 -  PROGRAMMING PEDESTRIAN OPENING RADIO CODES 

 (UP TO 62 CODES - CRX MODELS ONLY)

Programming can be done only when the gate is stationary.

1 -  Set DIP 1 to ON and then DIP 3 to ON.

2 -  The red led DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.

3 -  Press the remote control button (usually channel B) within the allotted 10 seconds. If the remote is properly 

memorized LED DL10 (green) blinks.

4 -  The programming time for codes is automatically renewed in order to memorize the next remote control.

5 -  To finish programming wait 10 seconds, or press the PROG button briefly. The red LED DL1 stops flashing.

6 -  Reset DIP 1 to OFF and DIP 3 to OFF.

   

NOTE: If LED DL1 CONTINUES BLINKING QUICKLY IT MEANS THAT DIP 1 IS STILL SET TO ON AND 

THAT ANY OPERATION IS REFUSED.

7 -  End of procedure.

CANCELLATION PROCEDURE FOR ALL PEDESTRIAN OPENING RADIO CODES

Cancellation can only be performed when the gate is stationary.

1 -  Set DIP 1 to ON and then DIP 3 to ON.

2 -  The red LED DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.

3 -  Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two flashes of green LED 

DL10.

4 -  The red LED DL1 remains active and you can add new codes as shown above.

5 -  Reset DIP 1 to OFF and DIP 3 to OFF.

6 -  End of procedure.

INDICATION MEMORY FULL OF PEDESTRIAN OPENING RADIO CODES

Indication only when the gate is stationary.

1 -  Set DIP 1 to ON and then DIP 3 to ON.

2 -  The green LED DL10 flashes 6 times when the memory is full (62 codes).

3 -  The LED DL1 will then remain active for 10 seconds enabling possible cancellation of codes.

4 -  Set DIP 1 to OFF and DIP 3 to OFF.

5 -  End of procedure.

C

ONTROL ACCESSORIES OPERATION

ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.

Make sure that any other type of command accessories (e.g. mass detectors) used on the installation 

are set in the IMPULSIVE mode, otherwise, the gate will be operated even without the protection of 

the safety devices.

STEP-BY-STEP BUTTON (COM-K BUTTON)

If DIP6 ON =>

   It cyclically performs the commands open-stop-close-stop-open etc.

If DIP6 OFF =>

  Opens the gate when closed. There is no effect if activated while opening. If activated when gate is 

open, the gate closes. If activated while closing, the gate reopens.

 


background image

34

34

G

B

OPEN BUTTON (COM-OPEN)

The button controls the opening movement when the gate is stationary. If activated while closing, it reopens the gate.

CLOCK FUNCTION OF OPEN BUTTON

If you want the Clock Function must request T2 24V with firmware 02.

ATTENTION:  A  CLOCK  CONNECTED  TO  T2  24V  with  fw  03  or  more  ACTIVATES  THE  OPENING 

MOVEMENT OF THE GATE WITHOUT HAVING THE PROTECTION OF THE SAFETY DEVICES!

This function is useful during peak hours, when vehicle traffic is slow (e.g. entry/exit of workers, emergencies in 

parking or residential areas and, temporarily, for moving operations).

CLOCK FUNCTION APPLICATION

It is necessary to request a T2 24V control panel with firmware 02.

 By connecting a switch and/or a daily/weekly 

clock (instead of or in parallel to the open button N.O. “COM-OPEN”), you can open and keep the automation open 

for as long as the switch is pressed or the clock remains active. Command functions are inoperative with open 

automation. Releasing the switch or at the preset time, the automation closes immediately.

CLOSE BUTTON (COM-CLOSE)

Controls the closing movement when the gate is stationary.

REMOTE CONTROL

If DIP6 ON =>

   It cyclically performs the commands open-stop-close-stop-open etc.

If DIP6 OFF =>

  Opens the gate when closed. There is no effect if activated while opening. If activated when gate is 

open, the gate closes. If activated while closing, the gate reopens.

PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)

Partial opening and closing control.

During pedestrian opening, pausing or closing, you can control the opening of any command linked to the T2 24V 

board. With DIP 6 you can choose the operation mode of the pedestrian push button.

If DIP6 ON =>

   It cyclically performs the commands open-stop-close-stop-open etc.

If DIP6 OFF =>

  Opens the gate when closed. There is no effect if activated while opening. If activated when gate is 

open, the gate closes. If activated while closing, the gate reopens.

 

ELECTRIC LOCK (LOCK)

Set DIP 8 to ON to enable control of the electric lock when opening.

ELECTRIC LOCK PULSE RELEASE IN OPENING

Set DIP 9 to ON to enable the electric lock pulse release when opening (provided DIP 8 is ON).

If a command to open the gate is given when the gate is closed, the closing movement is performed for 0.5 seconds 

and the electric lock is simultaneously activated (followed by a 0.5 second pause and then the opening of the gate).

ELECTRIC LOCK PULSE ENGAGEMENT

Set DIP 10 to ON to enable the pulse engagement of the electric lock when closing. Upon closing, motors are 

activated for 0.5 seconds at full voltage to ensure lock engagement. 

EASY MOTOR RELEASE

Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is ON), upon closing a reverse motion with a 

fixed time of 0.2 seconds occurs to facilitate manual release.

O

PERATION OF SAFETY ACCESSORIES

PHOTOCELL (COM-PHOT)

DIP 4 OFF =>  

if an obstacle is placed in range of the photocells when the gate is closed, the gate does not open. 

During  operation,  photocells  work  when  opening  (by  starting  the  opening  movement  only  after 

the obstacle is removed) and closing (by starting the reverse movement only after the obstacle is 

removed).

DIP 4 ON =>   

if an obstacle is placed in range of the photocells when the gate is closed and the command to open is 

given, the gate opens (the photocells do not work while opening). Photocells work only during closing 

(with reverse motion restored after a second, even if they are still engaged).

CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT OF PHOTOCELLS

DIP 16 ON and DIP 4 OFF =>   

if photocells are engaged during opening, the gate stops and the gate only closes one 

second after the photocells are disengaged.

DIP 16 ON and DIP 4 ON =>   

if  photocells  are  engaged  during  opening,  the  gate  continues  to  open.  Upon 

disengagement of the photocells, the gate stops and reverses closing motion after a 

one second pause.

 

 If  total  opening  is  reached  (end  of  opening  time),  immediate  closing  is 

deactivated  and  automatic  time  closing  is  activated  (if  TCA  trimmer  is 

activated and LED DL6 is on). If during closing there is a rapid movement (e.g. 

pedestrian) the gate will open again for two seconds and then close once again.

DIP 12 OFF => 

 

immediate closing after movement in front of the photocells is deactivated.

N.B.:

 Please check photocell operation at least every six months.

EDGE (SAFETY STRIP) (COM-EDGE)

If engaged during opening, reverses the motion when closing.

If engaged when closing, reverses the motion when opening.

If it remains engaged again, it performs a further reversal after 2 seconds, then performs an additional short reversal 

and then gives the sensor failure or engaged alarm (N.O. contact).

If the sensor remains engaged (N.O. contact) no movement is allowed. 

If not used, jump the terminals COM-EDGE.

MONITORING OF SAFETY SENSORS (A+ TEST A-)

Sensors can be monitored through the A+ TEST input and DIP 12 ON.

The monitoring consists of a functional test of the sensor run after every full gate opening.

Closing the gate is therefore permitted only if the sensors have passed the functional test after each opening.

CAUTION:

 MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED WITH DIP 12 ON OR DEACTIVATED 

WITH  DIP  12  OFF.  IN  FACT,  THE  FUNCTIONAL  TESTING  OF  SENSORS  IS  ‘POSSIBLE  ONLY  IF  THESE 

DEVICES HAVE THEIR OWN POWER SUPPLY.

A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12 SHOULD BE SET TO OFF.

SENSOR AUTOTEST ALARM (DIP 12 ON)

If the sensor fails the monitoring test after opening, an alarm is displayed by the blinker lighting up. Gate closure 

is not allowed in this condition. Normal operation can be restored only by repairing the sensor and pressing one of 

the activated controls.

STOP BUTTON (COM-STOP)

The STOP button stops the gate during any operation.

If held when the gate is fully open (or partially when using the pedestrian control) automatic closing is temporarily 

deactivated (if activated by the TCA trimmer and LED DL6 on). It is therefore necessary to use a new command to 

make it close.

The automatic closing function is reactivated on the next cycle (if activated by the TCA trimmer and LED DL6 on).

POWER SENSOR ALARM

The T2 24V control panel has automatic sensors that make the movement of the gate reverse in case of impact 

against  objects  or  persons  in  accordance  with  the  current  EN  standards  (always  use  the  right  tool  to  ensure 

compliance with the values imposed by the standard), without special adjustments on the control panel, as it operates 

using special internal software. If the power sensor is used in opening or closing (only in high-speed) and then again, 

in the opposite direction, the gate stops and then reverses for 1 second. 

The alarm status will be displayed by the blinker which will remain active for one minute, during which time you can 

restore gate operation by pressing any command button.

FUNCTIONING IN DEAD MAN MODE WHEN THE SAFETY DEVICES ARE FAILING

If the safety edge fails or remains engaged for more than 5 seconds, or if photocell fails or remain engaded for more 

than 60 seconds,  the open, close, k button and pedestrian commands will work only in dead man mode.

The signal that this mode has been activated is given by the blinking of the programming led.

With the blinking of the programming led, the opening and closing operation are allowed only with the command 

button pressed and held. The radio commands and that of automatic closing, will be excluded, since their use in this 

mode, is not allowed by the norms.

Once the failing safety device is repaired,  in automatic after 1 second, all standard commands that were selected, 

such as step by step, automatic mode, radio commands and automatic closing start functioning again.

Note 1:

  during this functioning in dead man mode, in case of damage to the safety strips (or photocells) the photocells 

(or safety strips) still work by interrupting the operation in progress.

Note 2:

  the stop command is not to be considered a safety command that can be bypassed in this mode. Therefore, 

when pressed or damaged, it will not allow any movement of the gate.

The dead-man operation is only an emergency operation which must be activated for a very short period and 

with the complete installation at sight so to have a secure and safe control of the system. As soon as possible 

however, the failing safety devices must be repaired and activated.

BLINKER

N.B.:

 This control panel can power ONLY BLINKERS ON A (ACG7061) CIRCUIT with lamps up to 24V and 20W.

PRE-BLINKING

DIP 5 - OFF => the motor and blinker begin simultaneously.

DIP 5 - ON => the blinker begins 3 seconds before the motor.

GATE OPEN WARNING LIGHT (COM-SIGNAL)

Signals when the gate is open, partially open or not closed completely. Turns off only when the gate is completely 

closed. This signal is active during programming. 

N.B.: 

Max 3 W. If push buttons or lamps are in excess, the control 

panel processes will be endangered and possibly halt operation.

 

OPERATION AFTER A BLACK-OUT (WITHOUT BATTERIES)

When the power supply comes back the DL1 led turns on and remains on for all the time the gate stays open. The led 

will turn off only once the gate is completely closed. It is recommended to fully open the gate. Let the gate close by 

itself or with automatic closing, or wait until the blinker stops flashing before commanding it to close.

This will allow the gate to realign. If, motors were released and moved from the normal position when closed during 

the blackout, the first movement after power returns must be complete.

If the black out occurs when the gate is still moving or when the gate is open and the first command sent after the 

black out is a closing command, the closing of the gate will be carried out with a total delay between the two gate 

leaves. Therefore, first the leaf M2 will close completely; once it is off, M1 will start closing. This separate movement 

of the two gate leaves is done to avoid their incorrect overlapping.

T

ECHNICAL SPECIFICATIONS

- Temperature range 

0 ÷ 55°C

- Humidity 

 <95% without condensation

- Voltage 

230V~ ± 10%   (120V/60Hz upon request)

- Frequency 

50/60 Hz

 


background image

35

35

G

B

- Battery power 

20-24Vdc

- Transformer Power 

 130VA - primary 230Vac - secondary 18Vac

- Maximum absorption 

50 mA

- Network Micro-switches 

100ms

- Maximum power gate open indicator 

 24Vdc 3W (equivalent to one 3W or 5 LED light bulb with 

resistor in series at 2.2 K ohm)

- Maximum blinker power 

24Vdc 20W

- Power available for photocells and accessories  1A ± 15%

- Power available for radio connector 

200Ma

RADIO SPECIFICATIONS (model T2 24V CRX)

- Receiving Frequency 

433,92 MHz

- Impedance 

52 OHM

- Sensitivity 

>2,24µV

- Pick-up time 

300ms

- Drop time 

300ms

-  All inputs must be used as clean contacts because the power is generated internally (secure power) to the board and 

is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage.

-  Any external circuits connected to the outputs of the control panel must be made in such a manner as to ensure 

compliance with double or reinforced insulation with regard to dangerous voltage.

-  All inputs are controlled by a programmed integrated circuit that performs a self check every time it starts operating.

T

ROUBLE SHOOTING

After  having  carried  out  all  connections,  by  carefully  following  the  layout  and  having  positioned  the  gate  in 

intermediate position, check the correct ignition of red LEDS DL7, DL8 and DL9

In case of no ignition of the LEDS, always with gate in intermediate position, check the following and replace any 

faulty components.

DL7  switched off  Faulty photocells

DL8  switched off  Faulty safety edge (In case the edge is not connected, carry out jumper between COM and EDGE)

DL9  switched off  Stop button malfunction (if Stop is not connected, perform the jump between COM and STOP).

During functioning with personnel present, with DIP 1 at ON, check that during opening of M1 and M2 the green DL2 

and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3 and DL5 LEDS switch on.

Or else, reverse the wires of the motor.

M

ECHANICAL BOLT

Mechanical bolt suitable for 2 leaves gate to latch closed the gate to the 

ground.                                                                       code ACG5000

E

LECTRIC LOCK

Horizontal lock - right external view - 12Vac                  code ACG8660

Horizontal lock - left external view - 12Vac                    code ACG8670

Vertical lock - 12Vac                                                    code ACG8650

B

ATTERY

Battery 2,2Ah 12V                                                       code ACG9515

B

ATTERY CHARGE CARD 

 

  

                                      

 code ACG4648

ACCESSORIES -

    For the connections and the technical data of the optional equipments follow the relevant 

handbooks.

After having carried out the various connections and having supplied voltage, all the LEDS 

are switched off.

The motor opens and closes, but it has no strength and moves slowly.

The gate opens but does not close after the time set.

The  gate  does  not  open  or  close  by  activating  the  various  K,  Radio,  Open  and  Close 

buttons.

The electric lock does not work.

LED DL1 blinks rapidly and no movement is activated.

Check fuses F1, FUSE 1. 

If the fuse is blown, use only a suitable replacement.

F1 T 2A   TRANSFORMER PROTECTION FUSE (on the outside of the T2 24V 

board)

FUSE 1 8A MOTOR PROTECTION FUSE

Check trimmers RUN and LOW-SPEED adjustment.

Make sure that the TCA trimmer is activated with LED DL6 on. 

OPEN button always on, replace the OPEN control button or switch. 

Sensor Auto test failed, check the connections between the control panel and the sensor power 

supply. 

Warning:

 If you are not using a power supply for the sensors, DIP 12 should be OFF.

Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.

Fix or replace the relative contact.

Ensure to have enabled DIP 8 at ON.

Place dip switches 1, 2 or 3 in the OFF position.

FAULT

SOLUTION

 


background image

36

36

G

B

S

ET SOLAR AMPLIFIER 

Interface for 50W solar panels. 

code AD00319

T

2 24V Wi-Fi

Control panel with impact sensors and MASTER Wi-Fi card. 

With container. 

code ABT2025W

Wi-Fi  DEVICES

M

ASTER Wi-Fi

RECEIVER CARD TO MANAGE WIRELESS SYSTEM

with connector - 12÷30V ac/dc 

code ACG6094

with terminal block - 12÷30V ac/dc 

code ACG6099

N

OVA Wi-Fi

PHOTOCELLS WITHOUT WIRES 

code ACG8037

PAIR OF COLUMS NOVA 

code ACG8039

T

OUCH Wi-Fi

STRIP WITHOUT WIRES 

code ACG3016

S

PARK Wi-Fi

BLINKER WITHOUT WIRES 

code ACG7064

LATERAL SUPPORT  

code ACG7042

B

LOCK Wi-Fi

KEY SELECTOR WITHOUT WIRES 

code ACG6098

Discover the only 

wireless automation devices 

at www.ribind.it.

 


background image

PRINCE 24V

Co

d.

 C

VA2

02

- 2

71

12

01

- R

ev.

 0

7

BA01046

CAL1158

CRS6204R

CPL1163

CME2125

CTC1269

CPL1164

CPL1165

CTC1253

CTC1116

DAC4X14

CME9056

CCA1263

CME5235

DRL10X30I

CCA1351

DTE10X20I

CVA1176

BA01076

DTM10X40I

DRL10X20I

DDD10MAI

CMO1286

CME6085

CAL1157

DAC29X95

CPL1167

CEL1457

CPL1127

DRD4

DTB55X40

ACG8088

Rond. Piana 4x10

Rond. Piana 10X20 INOX

Rond. Piana 10X30 INOX

Vite TCEI 5,5X38 autof. zinc.

Vite TE8X30 INOX UNI 5739

Vite TE10X20 INOX

Vite TE 10X40 INOX UNI 5737

DRL4X10Z

DRL10X20I

DRL10X30I

DTB55X40

DTE8X30I

DTE10X20I

DTM10X40I

ACG8088

BA01046

BA01076

CAL1157

CAL1158

CCA1263

CCA1351

CEL1457

CME5235

CME6085

CME2125

CME9056

CMO1286

CPL1127

Fermo meccanico in chiusura PRINCE

Serie access. cilind. PRINCE

Sacch. access. PRINCE

Semiguscio inferiore

Semiguscio superiore

Gruppo Forcella - Perno

Piastra cancello

Blocca cavo

Chiocciola bronzo

Forcella posteriore 

Boccola vite senza fine

Vite s/fine

Mot. PRINCE EPIC.MBT 24V

Supporto motore 24V-230W

Codice

Denominazione Particolare

CPL1163

CPL1164

CPL1165

CPL1167

CRS62042R

CTC1116

CTC1253

CTC1269

CVA1176

DAC29X95

DAC4x14

DAE55X16

DDD8MAI

DDD10MAI

Innesto-2 Prince

Innesto-1 PRINCE

Mozzo sblocco PRINCE

Piastra morsettiera

Cusc. 6204/2RS

Seeger E12

Molla ritorno sblocco

Spina CIL. 5X30 non temprata

Boccola 12X16X12 bronzo F7/R7

Vite aut.TC.CR. 2.9X9.5 zincat

Vite aut.TC.CR. 4X14

Vite aut. TC.TE 5.5x16 P.TRINCA Z

Dado autob. 8MA INOX

Dado autob. 10MA INOX alto

Codice

Denominazione Particolare

Codice

Denominazione Particolare

Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been 

completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia

  25014 CASTENEDOLO (BS) - ITALY

Via Matteotti, 162

Tel. +39.030.2135811

Fax +39.030.21358279

www.ribind.it - ribind@ribind.it

 


background image

SELF INSTALL - NEED TECHNICAL

ASSISTANCE?

OPTION 1: DIRECT WITH THE SERVICE DESK – QUICKEST AND MOST EFFECTIVE METHOD

Submit your enquiry direct with the service desk at –

service@automaticsolutions.com.au

The service desk has the most experienced staff in Australia to help with your problem but they need your help.

Describe your problem in detail and as clearly as possible. Don’t forget to include a telephone number.

Be certain to detail which model or models of you are working with.

Send photos of the installation – they love photos. The people at the service desk are good but they are

even better when they can see the installation. Send photos of the overall scene so they can see the

entire installation. Also send photos of the wiring to the control board and any other part of the

installation you think is relevant.

Send video if appropriate. Smartphone’s these days take remarkably good video in small file sizes which

can be emailed in a moment. If your problem needs a video to show the issue please feel free to send it.

NOTE: THIS IS BY FAR THE FASTEST AND MOST SUCCESFUL WAY TO SOLVE YOUR PROBLEM

PHOTOS AND VIDEOS ARE THE NEXT BEST THING TO BEING THERE

OPTION 2: LODGE YOUR ENQUIRY LOCALLY - SLOWER BUT CAN STILL BE EFFECTIVE

Make contact with the store of purchase. Branch staffs are typically not technicians and dependent on their length

of service will have varying degrees of technical knowledge. If they cannot help however they will certainly either

source help locally from their technicians or make contact with the service technicians on your behalf.

OPTION 3: SERVICE CALL WITH AUTOMATIC SOLUTIONS TECHNICIAN – SLOWEST METHOD

If you fall within the local branch service area it may be possible to book a local technician to look at your

installation. Wait times will vary dependent on local workloads. The cost is a service fee which includes the first

half hour and the hourly rate thereafter. If any Automatic Solutions provided parts are found to be defective and

within warranty these will be provided free of charge.

(NOTE: If you suspect that any parts are defective and within warranty you may wish to consider option 4)

A note on this option: If you decide on this option you will be asked to sign an “authorisation to proceed” which

will provide legal authority and payment security. This form has three options available of which only the first two

are available to you. The third option is for warranty repairs only for full install customers. Self install customers

requiring warranty only service need to refer to option four below.

IMPORTANT: IN SHORT THIS OPTION WILL INCUR CHAR

GES

OPTION 4: RETURN THE PRODUCT IF BELIEVED TO BE FAULTY

As a self install customer who has purchased product if you believe the product to be faulty rather than an

installation or site problem you have the option of returning the product for evaluation and to exercise your right

to a replacement, repair or refund as applicable. All returned product is forwarded immediately to the service

technicians for evaluation and response. There are two main methods available to return product –

Direct to the service centre – this is the quickest method as it cuts out the branch delay

Via the branch of purchase – slower because of the delay at the branch

When choosing this option you need to complete a product return form. This form gives you all the information

on procedure involved and where to send to.  These are available at the branch of purchase, can be emailed to

you (contact your branch), or available here -

http://automaticsolutions.com.au/page/warranty.php