background image

Touch-controller_IM_03943A_1_Co_EN.indd   2

2013-06-28   오후 3:06:00

 


background image

Touch Centralized Controller

MCM-A300N

Air Conditioner

installation manual

imagine 

the possibilities

Thank you for purchasing this Samsung product.

DB68-03943A(1)

EN ES FR IT PT DE EL RU AR

This manual is made with 100% recycled paper.

Touch-controller_IM_03943A_1_Co_EN.indd   3

2013-06-28   오후 3:06:00

 


background image

2

Safety precautions

This installation manual is for installing the Touch Centralized Controller. Read the installation manual thoroughly before 
installing the product. (Refer to the appropriate manual for installing other optional parts.)

 WARNING

• 

Hazards or unsafe practices that may result in 

severe personal injury or death

 CAUTION

• 

Hazards or unsafe practices that may result in 

minor personal injury or property damage

SEVERE WARNING SIGNS

Consult qualified installer or service center for installation. 

f

f

There is a risk of product malfunction, water leakage, electric shock or fire.

Install the product firmly on the place that can withstand the weight of the product.

f

f

If the installation location is not strong enough, product may fall and get damaged.

Connect the power with rated voltage when installing.

f

f

If not, there is risk of fire or damage to the product.

Do not attempt to move or re-install the product that is already installed.

f

f

There is risk of electric shock and fire.

Do not attempt to repair, disassemble, or modify the product yourself.

f

f

There is potential risk of product damage, electric shock or fire. When repair is needed, consult qualified installer or 
service center.

Check if the installation was done properly according to the installation manual.

f

f

There is risk of electric shock or fire if the product is installed incorrectly.

Make sure that all wiring work is done by qualified person complying regional standards and instructions in this 
manual.

f

f

If the installation is done by unqualified person, there is risk of product malfunction, electric shock or fire caused by 
incorrect installation.

Contact the service center when you need to dispose the product.

Touch-controller_IM_03943A_1_EN.indd   2

2013-06-28   오후 3:07:02

 


background image

3

ENGLISH

CAUTION SIGNS

Do not install the product in a place where it is or might be exposed to inflammable gas leakage. 

f

f

There is risk of fire or explosion.

Do not install the product in a place where it will be exposed to oil or vapor etc.

f

f

If the product is used in a place where it is exposed to oil, vapor or sulphur dioxide, parts of the product may get 
damaged or product may function abnormally. 

Make sure that water does not get into the product.

f

f

There is risk of electric shock and fire.

Make sure there is no tension to the cable during installation.

f

f

Cable may get cut and cause fire.

Install the product in a place with temperature between 0 °c~39 °c with no direct sunlight.

f

f

There is risk of electric shock or abnormal operation.

Do not install the product in a place where special spray or acid/alkali solution is used.

f

f

There is risk of electric shock or abnormal operation.

Do not press the button with sharp object.

f

f

There is risk of electric shock or damaging the parts.

Do not connect the power cable to the communication cable terminal.

f

f

There is risk of fire or explosion.

When installing the product in hospitals or other places, make sure that the product does not interrupt with other 
products.

f

f

Abnormal operation may occur.

Touch-controller_IM_03943A_1_EN.indd   3

2013-06-28   오후 3:07:02

 


background image

4

Before installation

Check list before the installation

Installation cables

Cables must be installed not to tightly to the wall where the product will be installed in prior to product installation.

Accessories

Before the installation, check if all the accessories are included with the product. Type and quantity of the accessories 
may be subject to change without prior notice.

Name

Touch Centralized 

Controller

Cable tie

M4 Screw

User's manual

Installation 

manual

Quantity

1

3

4

1

1

Image

• 

Touch Centralized Controller must be installed by the installation expert.

• 

Before installing the Touch Centralized Controller, check if the power is off.

• 

Communication cable must be installed according to the electrical wiring regulation and make sure that cable is 
installed through the wall so that it is not exposed to the users. (Use VCTF 2C х 0.75 mm

2

 Communication cable )

CAUTION

Touch-controller_IM_03943A_1_EN.indd   4

2013-06-28   오후 3:07:03

 


background image

5

ENGLISH

Selecting solderless ring terminal

1.  Select a solderless ring terminal for a power cable according to the nominal dimensions for cable.
2.  Apply insulation coating to the connection part of the solderless ring terminal and the power cable.

Silver solder

Nominal dimensions for cable (mm

2

)

1.5

2.5

Nominal dimensions for screw (mm)

4

4

4

4

B

Standard dimension (mm)

6.6

8

6.6

8.5

Allowance (mm)

±0.2

±0.2

D

Standard dimension (mm)

3.4

4.2

Allowance (mm)

+0.3

-0.2

+0.3

-0.2

d1

Standard dimension (mm)

1.7

2.3

Allowance (mm)

±0.2

±0.2

E

Min. (mm)

4.1

6

F

Min. (mm)

6

6

L

Max. (mm)

16

17.5

d2

Standard dimension (mm)

4.3

4.3

Allowance (mm)

+ 0.2

0

+ 0.2

0

t

Min. (mm)

0.7

0.8

Touch-controller_IM_03943A_1_EN.indd   5

2013-06-28   오후 3:07:03

 


background image

6

Name of the parts and product dimensions

Name of the parts

Front

Touch C

entralized C

ontroller

Control &

 

Monitoring

Schedule

Setting

SD card slot

LCD ON/OFF button
Indoor unit operation lamp (Blue)
Error lamp (Red)

Bottom

Power terminal

DI-1 terminal

Reset Button

DI-2 terminal

RS 485 communication terminal

DO Terminal

Touch-controller_IM_03943A_1_EN.indd   6

2013-06-28   오후 3:07:03

 


background image

7

ENGLISH

Product dimensions

203

170

(Unit : mm)

161

38

141

Touch-controller_IM_03943A_1_EN.indd   7

2013-06-28   오후 3:07:04

 


background image

8

Installing the Touch Centralized Controller

System diagram

S-NET 3

TCP/IP

DMS2

Touch Centralized Controller

Touch Centralized Controller

OnOff controller

Outdoor unit

RS 485

Maximum 128 indoor units

(DVM series)

Checking the power connection

1.  Press the LCD ON/OFF button to turn on the LCD.
2.  Check if the LCD turns on. 

 - If the LCD does not turn on, check the connection of the power(AC 100~240 V, 50/60 Hz) terminal and the power 

connector.

Checking the LED

1.  There is an error If the Error lamp (Red) turns on.
2.  If the Error lamp (Red) turns on, check the connection status of communication/power and the status of communication 

cable.

3.  If the Error lamp (Red) turns on, check if there is any error on the indoor unit that is connected to the Touch Centralized 

Controller.

Touch-controller_IM_03943A_1_EN.indd   8

2013-06-28   오후 3:07:04

 


background image

9

ENGLISH

Maximum allowable number of connections

Classification

When connected to control device layer

When connected to indoor/outdoor unit layer

Outdoor unit

16 units

1 unit

Indoor unit / ERV

128 units

80 units

Installing the Touch Centralized Controller

1.  Fix the installation plate of the Touch Centralized Controller on the wall with 4 screws.

2.  Connect the power cable to the power terminal on the back of the Touch Centralized 

Controller.

Tightening torque (N.m)

M4

1.2~1.5

[Arranging the wire in 

downward direction]

[Arranging the wire in 

upward direction (for 

in-wall wiring)]

Power cable

Communication cable

Fix it firmly with a 

cable tie

3.  Connect the communication cable to the 485 communication terminal on the back of the Touch Centralized Controller.

 - If the connection is not done properly, communication may not work properly.
 - Use appropriate tools to connect the cables firmly within rated torque range so that it can withstand external forces.
 - You may connect the communication cable of the F1, F2 terminal of the indoor/outdoor unit or R1, R2 of the outdoor 

unit. 

 - When connecting the Touch Centralized Controller to indoor/outdoor  unit layer use F1, F2 terminal and use R1, R2 

terminal when connecting it to control device layer.

4.  Hang the top part of the Touch Centralized Controller on the 

installation plate, already installed on the wall, and fasten the hooks on 
the bottom part of the installation plate.

 - Make sure to fix the Touch Centralized Controller firmly since it may 

fall to the ground and get damaged if it is not firmly fixed.

Installation plate  

Holes for the hooks

• 

It is recommended to install the product on the wall  for safe use and to prevent it from troubles and damages.

CAUTION

Touch-controller_IM_03943A_1_EN.indd   9

2013-06-28   오후 3:07:05

 


background image

10

Installing the Touch Centralized Controller

Tracking 

Through tracking function, Touch Centralized Controller searches for the device that forms a system and registers the 
installation & status information of those devices.
1.  When you go to [Setting] 

 [Installation settings] 

 [Network & Tracking] menu and tap [Tracking] button, tracking will 

begin after user authentication.

2.  Tracking will run for maximum 10 minutes. 

 - If the number of connected outdoor unit increases, it may take long time for tracking. 

3.  When the tracking is done, you can check the list of searched devices. 
4.  You can select Show/Hide ( 

 ) for the device that has completed the tracking. 

 - You can also hide the device which is found during the tracking with the Hide function. 

5.  Indoor units that has disabled centralized control option will be fixed to 'Hide' status and it cannot be changed.

Setting for external contact control through DI port (Optional)

Setting DI pattern 

You can set the DI pattern from [Setting] 

 [System settings] 

 [DI pattern] menu.

f

f

DI port

Dry contact must be connected.

DI-1 (+,-)

DI-2 (+,-)

Control pattern

Pattern

Description of control

1

• 

No external input (Factory default setting)

• 

Nothing will happen when contact signal is inputted to port 1.

2

• 

When DI-1 ON signal is input, emergency stop status will occur. 

• 

It will stop all indoor units and order the indoor units not to be controlled by a remote controller. 

• 

In the emergency stop status, you cannot use the user control command. In addition, the schedule 
control will not work. When the contact control signal is changed to OFF, the control command can 
work normally. (DI-2 will not be used with the pattern 2) 

3

• 

When DI-1 ON signal is input, it will stop all indoor units. When OFF signal is input, all indoor units are 
ON. 

• 

When DI-2 ON signal is input, the remote control status of all the indoor units will be enabled and when 
the OFF signal is input, the remote control status will be disabled.

4

• 

Valid pulse width of the input signal is between 0.5~1.0 second. Signals with pulse width below 0.5 and 
over 1.0 second will be ignored.

• 

When the pulse contact signal is input to DI-1, ON command will be sent to all indoor units.

• 

When the pulse contact signal is input to DI-2, OFF command will be sent to all indoor units.

Touch-controller_IM_03943A_1_EN.indd   10

2013-06-28   오후 3:07:05

 


background image

11

ENGLISH

DO port

f

f

DO operation specification

DO output will turn on if any one of the indoor unit is turned on. DO output will 
turn off if all the indoor units are turned off.

f

f

DO port

(+)terminal outputs 12 V, (-) terminal outputs open collector, Drive current 
under 10 mA.

DO (+,-)

Touch-controller_IM_03943A_1_EN.indd   11

2013-06-28   오후 3:07:05