PDF User Manual

  1. Home
  2. Manuals
  3. Siegenia KVF Genius Assembly Instructions Manual

Siegenia KVF Genius Assembly Instructions Manual

Made by: Siegenia
Type: Assembly Instructions
Category: Locks
Pages: 16
Size: 1.32 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

W I N D OW   H A R DWA R E

D O O R   H A R DWA R E

S L I D I N G   D O O R   H A R DWA R E
V E N T I L AT I O N   T E C H N O LO GY
B U I L D I N G   T E C H N O LO GY

D O O R   H A R DWA R E

GENIUS

Elektronic door lock

Asse mbl y  I ns tr u ct ions

 


background image

 


background image

1

Last update: 01.08.2013

Assembly instructions

GENIUS

Contents

Target group of this documentation..............................................................   2

Intended use................................................................................................   2

Improper use...............................................................................................   2

Safety notes.................................................................................................   2

Explanation of symbols...............................................................................    3

Rotary switch (optional signal outputs).........................................................   3

Installation..................................................................................................   4

GENIUS door lock connections......................................................................   5

Cable links..................................................................................................    7

Fitting the door contact.................................................................................   8

Fitting an internal release push-button (optional)..........................................   9

Fitting the infra-red eye (optional).................................................................  9

Wiring diagram for type A GENIUS door lock................................................10

Wiring diagram for type B GENIUS door lock.................................................11

Technical specifications..................................................................................12

Liability.........................................................................................................12

 


background image

2

Last update: 01.08.2013

GENIUS

Assembly instructions

Target group of this documentation

This documentation is intended to be used by specialists only. All work described in this document is to be performed by 

experienced professionals with training and practice in the assembly, installation and maintenance of the GENIUS door 

lock and its individual components. Safe and proper assembly of this electronic door lock is not possible without expert 

knowledge.

Intended use

• 

The GENIUS door lock is a special lock for automatically locking and unlocking doors.

• 

It is suitable for installation in timber, aluminium, steel and PVC entry doors for residential and public buildings.

• 

All assembly and electrical installation work must be carried out according to our assembly and installation instruc-

tions. Wiring the unit incorrectly can irreparably damage its electronic components.

• 

The GENIUS door lock must be used with a free-running cylinder compliant with the German standard DIN 18252. 

Alternatively a thumbturn cylinder can be used, but it should be noted that this will result in a loss of power at the 

locking points.

• 

The GENIUS door lock can be connected to an external access control system (e.g. wireless, transponder or finger-

print scanner system) via a voltage-free contact (switching time: min. 1 second).

• 

Use the GENIUS door lock only when it is in a technically sound condition. Do not modify the unit's components in 

any way.

• 

Use the GENIUS door lock only with genuine KFV accessories.

Improper use

• 

The GENIUS door lock must not be used with a cylinder with a fixed catch, as this will cause the main lock to jam 

when the key is removed.

• 

The GENIUS door lock must not be installed in moisture-prone areas or areas with a corrosive atmosphere (e.g. elect-

roplating shops).

• 

The length of the cable between the power supply and the GENIUS door lock must not exceed 13 m.

Safety notes

• 

Work on an 230 V AC mains power supply may only be performed by a qualified electrician.

• 

All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regu-

lations (e.g. VDE 0100) and any relevant country-specific requirements.

• 

All-pole safety isolation should be used when fitting the power lead on-site.

• 

Some external access control systems available on the market transmit a brief "open" signal when the operating vol-

tage is switched on. This can mean that the GENIUS door lock will open the door following a power cut. If in doubt, 

please contact the system manufacturer.

Where power supply cables are routed parallel to data cables (IDSN, DSL etc), interference can occur, eg: with 

the data transfer speed.

Warning

 


background image

3

Last update: 01.08.2013

Assembly instructions

GENIUS

Explanation of symbols

Milling cutter or drill diame-

ter

Groove depth from profile

Groove length

Rotary switch (optional signal outputs)

• 

The rotary switch can only be operated when the lock is not installed.

• 

The rotary switch is used to control the optional signal output, terminal 7. The output must not be subjected to a cur-

rent of more than 20 mA.

• 

The rotary switch on the type B GENIUS door lock is used, if desired, to define the lock or door status that should 

trigger the optional signal output.

• 

Via an external relay (a 24 V DC coupling relay, available as a KFV accessory) connected to terminal 7, the GENIUS 

door lock can be linked to other systems, e.g. alarm systems and hinged door drives.

Fig. 1: Rotary switch

Position

Status

Comments

The lock is fully locked and the door 

is shut.

• 

For use in conjunction with alarm systems.

 ›    Terminal 7 is connected to negative (-) ground.

The door is shut

• 

For use in conjunction with monitoring by a porter.

 ›    Terminal 7 is connected to negative (-) ground.

The latch is drawn into the cylinder 

operated lock

• 

For use in conjunction with a hinged door drive.

 ›    Terminal 7 is connected to negative (-) ground.

Can be used to arm/disarm a con-

nected alarm system

• 

Controlled using a 2-channel infra-red access key*

• 

In order to keep the alarm system armed in the event of a power 

failure, the terminal is connected to negative/ground when the 

alarm is disarmed.

›     Alarm disarmed = terminal 7 = negative -- relay on
›     Alarm armed = terminal 7 = high resistance -- relay off

• 

The break contact of the relay must be used to switch on the 

alarm system.

*See GENIUS operating instructions for details of how to do this

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

 


background image

4

Last update: 01.08.2013

GENIUS

Assembly instructions

Installation

Fitting the GENIUS door lock

The GENIUS door lock is supplied pre-installed. It only needs to be screwed in for retrofitting or replacement purposes.

3x

Fig. 2: Fitting the GENIUS door lock

Fitting the power supply

• 

The power supply ensures that the GENIUS door lock is supplied with the 

right voltage.

• 

Its casing is designed to be fitted on a standard DIN EN 60715 mounting 

rail.

• 

One power supply can supply one GENIUS door lock and one KFV access 

control (wireless, transponder, infra-red or fingerprint scanner) system.

• 

The power supply comes with a permanent connection. An easily-accessible 

means of disconnecting it must be integrated into the power supply circuit.

Fig. 3: Power supply

Fitting cables

      Various types of cable are available for connecting the power supply to the GENIUS door lock.

      Each cable is marked with a band to show where it must be plugged into the GENIUS door lock.

      

Important:

• 

When routing cables behind the face plate, ensure that they are not vulnerable to damage from the drive rod or 

other moving parts.

• 

The shield must be connected to earth on the power supply side. On the GENIUS side, connection of the shield is not 

necessary.

 


background image

5

Last update: 01.08.2013

Assembly instructions

GENIUS

GENIUS door lock connections

Connec-

tions

Type 

A

Type 

B

Function

A, B, C, D

B, C, D, 2

Connection for infra-red eye, which 

sends infra-red signals to the GENIUS 

door lock

Connection for the KFV fingerprint 

scanner

0, 1

Switching between

day/night mode

2, 3

Operating voltage 24 V DC

Terminal 2 = + (positive)

Terminal 3 = -- (negative)

4

External "unlock" signal.

In both operating modes, if +24 V DC 

is applied to this terminal for 

1 s, the 

door will be opened

7

Indicating door/lock status.

A rotary switch is used to define the sta-

tus in which a signal is triggered (optio-

nal signal output, max. 20 mA)

Fig. 4: GENIUS door lock connections

          (shown: type B)

Cable types
Type F

Always used together with type B.

0

1

2

3

4

7

Cable

no.

Band 

colour

Cable 

colour

Function

0

Black

Grey

Switching between 

day/night mode

1

Brown

Yellow

Switching between

day/night mode

2

Red

White

Operating voltage (+) 24 V DC

3

Blue

Brown

Operating voltage (--) negative

4

Yellow

Green

External "unlock" signal

7

Violet

Pink

Indicating door/lock status

Fig. 5: Cable type F (for connection to Genius)

Type B

Always used together with type F.

0

1

4

7

+

-

Cable

no.

Band 

colour

Cable 

colour

Function

0

Black

Grey

Switching between

day/night mode

1

Brown

Yellow

Switching between

day/night mode

4

Yellow

Green

External "unlock" signal

7

Violet

Pink

Indicating door/lock status

--

Blue

Brown

Operating voltage (--) negative

+

Red

White

Operating voltage (+) 24 V DC

White

Blue

Shield

Fig. 6: Cable type B (for connection to KFV power

          supply)

 


background image

6

Last update: 01.08.2013

GENIUS

Assembly instructions

Type K

Cable

no.

Band 

colour

Cable 

colour Function

4

Yellow

Green

External "unlock" signal

--

Blue

Brown

Operating voltage (--) negative

+

Red

White

Operating voltage (+) 24 V DC

White

Blue

Shield

Fig. 7: Cable type K (connects Genius to power 

          supply)

Type E

Fig. 8: Cable type E (connects Genius - type A only-

          to power supply)

0

1

2

3

4

7

0

1

4

7

+

-

4

+

4

+

Cable plugs for the GENIUS door lock

• 

To facilitate installation of the GENIUS door lock, the plug can be removed by pulling it upwards.

• 

There are letters on the plug to indicate where the various cables should be plugged in.

2 3

4

2

3

4

A

B C

D

0

1 2

3

4

7

GENIUS type A

GENIUS type B

Fig. 9: Cable plugs for the GENIUS door lock

Cable

no.

Band 

colour

Cable 

colour Function

0

Black

Grey

Switching between

day/night mode

1

Brown

Yellow

Switching between

day/night mode

4

Yellow

Green

External "unlock" signal

7

Violet

Pink

Indicating door/lock status

-- /3

Blue

Brown

Operating voltage (--) negative

+ /2

Red

White

Operating voltage (+) 24 V DC

White

Blue

Shield

 


background image

7

Last update: 01.08.2013

Assembly instructions

GENIUS

Cable links

Visible cable link

• 

The visible cable link should be fitted to the inside of the door on the hinge side.

• 

If this cable link is used, unhinging the door leaf requires substantial effort.

Fig. 10: Visible cable link

Concealed cable links

100° and 180° concealed cable link

• 

The casing is fitted in the door frame or leaf.

• 

Allows the door leaf to be unhinged where cable types 

B/F are used.

Fig. 11: Concealed cable link, not disconnectable

This cable link is used for routing cables invisibly in the door rebate.

Fig. 12: Concealed cable link

100° and 180° concealed cable link, disconnectab-
le

Cable link is easy to disconnect using the plug connector in 

the area of the rebate.

• 

The casing is fitted in the door frame or leaf.

• 

The disconnectable cable link permits easy unhinging of 

the door leaf.

Fig. 13: Concealed cable link, disconnectable

 


background image

8

Last update: 01.08.2013

GENIUS

Assembly instructions

Fitting the door contact

Important

: Do not allow the magnet to come directly into contact with the face plate as this can permanently magnetise 

the face plate or the drive rod behind it.

• 

The GENIUS door lock uses an integrated door contact (reed sensor) to detect whether the door is open or shut.

• 

The reed sensor is triggered by a counter part (magnet) that must be fitted on the frame side. This magnet is vital to 

the correct functioning of the GENIUS door lock.

Fig. 14: Available magnet bushes

1

Round magnet bush

2

Oval magnet bush

3

Adhesive magnet bush

• 

The magnet must be positioned centrally in relation to the reed sensor (vertical tolerance: ±1 mm).

• 

The distance (airgap) between the locking rail/face plate must be 4 mm (tolerance ±3 mm).

min. 4

3

+

Fig. 15: Position of reed sensor in relation to magnet

• 

If using striker plates for timber doors, the magnet and holder can be fitted directly in the frame.

• 

If using striker plates for PVC or aluminium doors, a single AS23xx striker plate (without backing) must be fitted in the 

area of the reed sensor together with a plastic component, with magnet, suitably sized to fit the hole.

• 

If the GENIUS door lock is used in conjunction with inactive leaf hardware, 1 mm-thick magnets must be bonded in 

place exactly opposite the reed sensor, because no holes may be made in the inactive leaf hardware.

 

›   Degrease the rail on the inactive leaf hardware in the area where the magnets are to be applied.

 

›   Determine the necessary positions and number of magnets. If necessary, used several magnets one on top of 

                the other.

 

›   Mark the desired magnet position, remove the backing film from the magnet, and stick it in place.

 


background image

9

Last update: 01.08.2013

Assembly instructions

GENIUS

Fitting an internal release push-button (optional)

The internal release push-button can be used to open the door 

without a conventional key.

›   Connect the cable (length: 750 mm) to terminals 2 and 4 on 

    the GENIUS door lock.

›   Drill an 18 mm (without anchor) or 20 mm (with anchor) drill

    hole. 

   

Supplied with an anchor for "snap-in" installation.

Anti-intruder advice: 

To effectively prevent intruders from operating the push-button from the outside, it should be 

ensured that any glass panes and infill panels in the door are suitably burglar-resistant.

The infra-red eye acts as a receiver for the infra-red code 

transmitted by an infra-red access key or infra-red master key. It 

comes with an installation anchor suitable for use in any door 

material.

›   Drill a hole of diameter 20 mm (tolerance ±0.2 mm).

›   Push the infra-red eye into the anchor, guiding the cable 

    (length: 750 mm) in first.

›   Guide the cable from the infra-red eye to the GENIUS door 

    lock and connect it to the terminals on the (4-pin) plug on the 

    GENIUS door lock.

Fitting the infra-red eye (optional)

 


background image

10

Last update: 01.08.2013

GENIUS

Assembly instructions

Wiring diagram for type A GENIUS door lock

DSP 30

24V DC

Kl. 4 Fl.

( +24 V DC)

2

3

4

24VDC

2

4

3

5

6

7

8

1

No.

Description

1

230 V AC supply cable (L; N; PE)

2

Power supply

3

Wireless receiver (optional)

4

External unlocking feature (optional)

5

Max. line length 50 m (external unlocking feature)

6

Max. line length 13 m (from GENIUS door lock to power supply)

7

Internal release push-button (optional)

8

Type A GENIUS door lock

 


background image

11

Last update: 01.08.2013

Assembly instructions

GENIUS

Wiring diagram for type B GENIUS door lock

2

2

3

4

1

3

7

4

24VDC

1

4

5

6

8

7

9

10

max. 20 mA

A

B

C

D

0

1

11

DSP 30

24V DC

Kl. 4 Fl.

( +24 V DC)

2

3

1

No.

Description

1

230 V AC supply line (L; N; PE)

2

Power supply

3

Wireless receiver (optional)

4

External unlocking feature (optional)

5

Max. line length 50 m (external unlocking feature)

6

Time switch (optional)

7

Max. line length 13 m (from GENIUS door lock to power supply)

8

24 V DC coupling relay (optional)

9

Infra-red eye (optional)

10

Internal release push-button (optional)

11

Type B GENIUS door lock

 


background image

12

Last update: 01.08.2013

GENIUS

Assembly instructions

Liability

Intended use

Any use of this product that is not in accordance with its intended use, or any adaptation of or modification to the product 

and its associated components for which our express consent has not been obtained, is strictly prohibited. We accept no 

liability whatsoever for any material losses or injury to people caused by failure to comply with this stipulation.

Product liability

Our products are warranted – subject to correct installation and proper use – for a period of one year from the date of re-

ceipt by a company (according to our general terms and conditions) or as otherwise agreed, and for a period of two years 

for end consumers, in accordance with statutory provisions. As part of our ongoing improvements, we reserve the right to 

replace individual components or entire products. Consequential losses resulting from defects are excluded from the war-

ranty within the limits of the law. The warranty shall become void if modifications that are unauthorized by us or have not 

been described in this documentation are performed on the product and/or individual components, or if the product and/or 

individual components is/are dismantled or partly dismantled, and the defect is due to the changes made.

Exclusion of liability

The product and its components are subject to stringent quality controls. As a result, they function reliably and safely when 

used correctly. Our liability for consequential losses and/or claims for damages is excluded, except in the case of wilful mis-

conduct or gross negligence, or where we are responsible for injury to life, limb or health. Strict liability under the German 

Product Liability Act (Produkthaftungsgesetz) remains unaffected. Liability for the culpable violation of significant contractual 

obligations also remains unaffected; liability in this case is limited to losses that are specific to the contract and that could 

have been foreseen. The above regulations do not imply a change in the burden of proof to the detriment of the consumer.

Environmental protection

Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act (ElektroG), KFV 

will continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are 

hazardous to the environment as soon as this becomes technically feasible. Electrical products should not be disposed of as 

household waste.

Feedback on documentation

We welcome your comments and suggestions on how to improve our documentation. Please send us your feedback by e-

mail to dokumentation@kfv.de.

We, KFV KG, declare under our own responsibility that this product complies with the provisions of 

Directives 2008/108/EC and 2006/95/EC of the Council of the European Union.

EU Declaration of Conformity

Technical specifications

Relative humidity

20 % bis 80 %

Ambient temperature in door

-- 10 bis + 45 °C

Dimensions

Width 16 mm, length approx. 252 mm, depth 49 mm + width of face plate

Supply voltage

24 V DC max. 500 mA

Cable types

Type

LIYCY

Ambient temperature, non-fixed

-- 5 bis + 50 °C

Ambient temperature, fixed

-- 20 bis + 70 °C

 


background image

13

Last update: 01.08.2013

Assembly instructions

GENIUS

 


background image

H39.ELEKKFV0002EN/2013-08/0

A company of the SIEGENIA GROUP

Contact your dealer:

KFV Karl Fliether GmbH & Co. KG
Siemensstraße 10
42551 Velbert
GERMANY

Phone:  +49 2051  278-0
Fax:  

+49 2051 278-167

info@kfv.de
www.kfv.de

SIEGENIA worldwide:

Austria

  Phone: +43 6225 8301

Belarus

  Phone: +375 17 3121168

Benelux

  Phone: +32 9 2811312

China

  Phone: +86 316 5998198

France

  Phone: +33 3 89618131

Germany

  Phone: +49 271 39310

Great Britain

  Phone: +44 2476 622000

Hungary

  Phone: +36 76 500810

Italy

  Phone: +39 02 9353601

Poland

  Phone: +48 77 4477700

Russia

  Phone: +7 495 7211762

South Korea

  Phone: +82 31 7985590

Switzerland

  Phone: +41 33 3461010

Turkey  

Phone: +90 216 5934151

Ukraine

  Phone: +380 44 4637979

You can fi nd address details for our
 international sites at: www.siegenia.com