Mini Ammeter User Manual WF-D02A 

 

  Foreword 

     

           

Thanks for choosing this product. 

 

 

 

This  product  not  only  provides  power  connection  for  the  electric  appliances;  but  also 

records  operations  of  the  appliances.  Operation  conditions  on  the  display  includes: 

voltage of power supply, real-time running power, electricity consumption, electricity cost, 

running time… At  the  same time,  it  provides  analysis  on  real-time running  power  and 

gives  out  alarm  automatically  once  abnormal  operation  occurs.  This  helps  to  use  and 

maintain the appliances scientifically as well as save power and reduce waste. So, it is 

also called “power-saving guardian”. 

 

 

 

Usage 

 

Extremely easy to use

 

 

Down   

Up   

 

Menu   

 

LCD Display 

 

LED Indicator 

 

Socket 

Plastic shell 

 


background image

 

 

1. Connect the ammeter to an outer power supply, it starts working; the red indicator and 

the LCD backlight are lightened immediately. 

 

2. Insert the detection-waiting appliance into the ammeter, the ammeter starts real-time 

detection for operation condition of the appliance. 

 

3.  Connect  the  ammeter  to  the  power  supply  only,  but  disconnect  it  with  any  other 

appliance, the following operations are still working: 

Voltage of power supply can be measured; 

Records of the former accumulated electricity consumption and cost can be read

;

 

Relative functions and data can be set, including: electricity price, ratio of operation     

condition, standby power. 

 

4. Adaptable voltage: 220V/50Hz or 110V/60Hz (for different versions) 

Peak load: 15 A 

 

5.

 

Limit to indoor use. Environmental Conditions: Temperature: -10 ~ 60 °C; Humidity: 

10~95% RH 

6. New functions:   

1)  Two  ways  for  calculating  operation  time:  time  in  single  operation  period  and 

accumulated time in all operation periods; can be manually cleared to 0. 

2)  Two  ways  for  calculating  power  consumption  and  power  cost:  electricity 

consumption and electricity cost in single operation period and accumulated electricity 

consumption and electricity cost in all operation periods; can be manually cleared to 0. 

3) Ratio of operation condition and standby power can be pre-set. 

 

 

Display 

 

                                                         

                                                                                                                                                 

 

Display scope: 

1. AC Voltage: 160~280V/50Hz or 90~150V/60Hz (for different versions) 

2. Power: 1~3000W (can display running power less than 1W.) 

3. Electricity consumption: 0.0001 ~ 999.9 KWh 
4. Electricity cost: 0~9,999 $ 

5. Ratio of operation condition: 0~100% 

Units 

Functions 

Value 

Time

 

Unit  for  Ratio  of 

Operation Condition   

 


background image

 

 

6. Running Time

0 ~ 60 minutes to 24 hours to 999 days 

7. Measurement Accuracy: ±1% 
8. Refresh rate: more than one time per second 
 

. Display Status

 

1. Default display shows the voltage

 

2.  Ratio  of  operation  condition:  Ratio  between  accumulated  running  time  per 

hour (running power is over pre-set standby power) and 1 hour. The indicator 

light will flicker when the real ratio reaches the set ratio. 

3. Re-start this ammeter after power down, running time on the display restarts with 0. 

4. The background light of LCD can Auto. Off after 15 seconds. 

 

  Display units:   

1. AC Voltage: ×××× V ;   
2. Accumulated electricity consumption: ×××.× kWh 
3. Accumulated electricity cost: ××.×× $ 

3.

 

Running Power: ×××.× W ; 

4. Ratio of operation condition:×××%;   

5. Time: ××:×× (hours: minutes) 

                      ××× D (days) 

IV Buttons: 

    UP: Check data, add value, clear accumulated records into 0. 

Press on “UP” button, the cursor on the top of the display will move to the left, and data 

on the display changes accordingly to show different measured value; under set mode, 

press “UP” button to add preset value; press and hold “UP” button for 10~15 seconds to 

clear  accumulated  record  into  0,  including  all  accumulated  records

 

in  all  operation 

periods. 

 

    DOWN: Check data, reduce value, clear records in simple operation period into 0. 

    Press on “DOWN” button, the cursor on the top of the display will move to the right, and 

data  on the  display changes  accordingly  to  show  different measured  value;  under set 

mode, press “DOWN” button to reduce preset value; press and hold “DOWN” button for 

10~15 seconds to clear racords in single operation period into 0, including all calculated 

records in single operation period. 

 

    MENU: Short press to check accumulated records in all operation periods, including 

accumulated operation time, electricity consumption and electricity cost; press and hold 

“MENU” button for 5~10 seconds, the ammeter steps into set mode, and “SET” cursor 

flickers  on  the  display.  Three  values  can  be  preset:  unit  price  for  electricity,  standby 

power and alarm point of the ratio of operation condition. Press “UP” or “DOWN” button 

to adjust the values, and press “MENU” again to confirm the preset value. If there’s no 

operation on the buttons for some time, the ammeter will automatically exit set mode 

and turn to normal measurement mode. 

 

Set up 

 


background image

 

 

 

.

 Set up unit price for electricity cost:   

Press “MENU” button for 5~10 seconds, when the screen shows “Pr.” and “ST” on the 

bottom, “ST” flickers, and unit shows “$”, figures show the unit price for electricity(as 

shown below); figures (unit price) can be changed by pressing "UP" or "DOWN" button. 

When setting is completed, press "MENU" button again, thus price setting is completed. 

 

 

 

. Set up ratio of operation condition 

Press “MENU” button for 5~10 seconds, when the screen shows “RT” and “ST” on the 

bottom,  “ST”  flickers,  and  unit  shows  “%”,  figures  show  the  ratio  of  operation 

condition(as shown below); figures can be changed by pressing "UP" or "DOWN" button. 

When  setting  is  completed,  press  "MENU"  button  again,  thus  the  ratio  of  operation 

condition is set.

   

 

 

III. Set up standby power 

Press “MENU” button for 5~10 seconds, when the screen shows “PW” on the top and 

“ST” on the bottom, “ST” flickers, and unit shows “W”, figures show the standby power(as 

shown  below);  figures  can  be  changed  by  pressing  "UP"  or  "DOWN"  button.  When 

setting is completed, press "MENU" button again, thus the ratio of operation condition is 

set. Standby power is usually stated on appliance or its user manual; users can set up 

standby power on the ammeter accordingly (a bit higher than the stated one on appliance 

is  better).This  product  will  automatically  monitor  the  operation  condition  of  appliance 

according to the set standby power and the ratio of operation condition, as well as give 

out alarm accordingly. 

 

 

IV. Clearance of records 

Press  and  hold  “UP”  button  for  10~15  seconds  to  clear  accumulated  record  into  0, 

including all accumulated records in all operation periods; 

Press and hold “DOWN” button for 10~15 seconds to clear records in single operation 

period into 0, including all calculated records in single operation period. 

 


background image

 

 

 

Operation Manual 

 

1.

 

  Voltage  measurement  for  power  supply:  insert  the  ammeter  into  electrical 

outlets, repeatedly press "UP" or "DOWN" button to make the screen displays "AV” 

and the unit shows “V”, figures on the screen show the real-time voltage of the power 

supply  (as  shown  below).  This  product  can  be  used  to  measure  and  display 

160~280V AC voltage (or 90~150V AC for US version). 

 

 

2.

 

Check electricity consumption: operate as above to make the screen display “EC” 

and the unit shows “kWh”, figures on the screen show the electricity consumption (as 

shown below). The ammeter displays amount in four decimals; when accumulated 

electricity consumption is over 1kWh, it displays in pure decimal and integer 

alternately. It can real-time measure and display 0.0001 ~ 999.9 kWh of electricity 

consumption; if connect with electrical appliance of 1,000W, the last figure will 

increase by one in about three seconds.   

Moreover, with data storage function under power-down mode, all records won’t be 

lost under long-time power down. Accumulated electricity consumption can be 

cleared to zero by pressing “DOWN” button for 5~10 seconds, but the accumulated 

electricity cost and running time will be cleared to zero at the same time.   

 

 

3. Measure real-time running power: operate as above to make the screen display 

“PW” and the unit shows “W”, figures on the screen show the real-time running power of 

the appliance(as shown below). 

 

 

4. Check electricity cost: operate as above to make the screen display “PC” on the 

bottom and the unit shows “$”, figures on the screen show the electricity cost (as 

shown below). This ammeter can real time measure the electricity cost for electrical 

appliance; the smallest sub-display unit is “cent”. If electricity is priced at $0.6/kWh, 

 


background image

 

 

using with electrical appliance of 1,000 watts for about one minute, the last figure will 

increase by one (the electricity cost is 1 cent). Accumulated electricity cost can be 

cleared to zero by pressing “DOWN” button for 5~10 seconds, but the accumulated 

electricity consumption and running time will be cleared to zero at the same time.

 

 

 

 

 

5. Monitor operation conditions of electrical appliance:   

Operate as above to make the screen display "RT" and the unit shows "%", figures on the 

screen show the real-time ratio of operation condition.(as shown below) 

Principle: Red indicator light flickers if the  real-time running power is  over  the  set 

standby  power  for  a  period  of  time  (=1  hour  x  the  ratio  of  operation  condition, 

accumulated time in 1 hour). For example: 

1)

 

set ratio to 100% and standby power to 70W: 

When the real-time running power is over 70W during the past 1 hour, the ammeter 

will give out alarm (the indicator flickers); 

2)

 

Set ratio to 50% and standby power to 70W: 

When the real-time running power is over 70W for 30mins (50% x 1 hour) during the 

past 1 hour, the ammeter will give out alarm (the indicator flickers). 

This function is particularly applicable to the refrigeration, heating and other           

equipment to monitor their operation conditions. 

 

6. Check running time of electrical appliance: running time shows on the top right 

corner.  It  is  the  running time  record  of  both the  appliance  and  the  ammeter.  It  stops 

recording while power down, and restart to record from zero when connect to the power 

again. Running time can be cleared to zero by pressing “DOWN” button for 5~10 seconds, 

but the accumulated electricity consumption and cost will be cleared to zero at the same 

time. 

Two formats for display: 

 

    hh: mm (hours: minutes),":" flickers once a second, figures on “mm” increase by one 

every 60 seconds (as shown below). 

 


background image

 

 

 

 

    ××× D (day): unit shows “D” beside the figures(as shown below). 

 

When  the  running  time  is  less  than  24  hours,  figures  will  show  in  format 

    ;  when 

running time surpasses 24 hours, figures will show in both format 

    and 

    alternately. 

 

Application Example

 

                                                                                                                                                                           

1

 

Measure  if  the  power  supply  has  electricity  and  if  the  socket  is  in  good 

condition:   

Insert the ammeter into the socket of power supply, if the power supply has electricity 

and the socket is in good condition, the LED indicator will flicker and LCD backlight will be 

lightened.  It  can  replace  the  neon-electroscope,  especially  when  you  find  there  is 

electricity in the socket by the neon-electroscope, but it is abnormal when connecting 

with the electrical equipments. At this very moment, it is easy and effective to use this 

ammeter to tell whether the power supply or socket is in good condition.   

 

2

Observe the real-time voltage fluctuations of power supply:   

Choose the Voltage Measurement function, you can real-time observe and measure 

the voltage fluctuation of power supply. It can be functioned to replace voltmeter.     

 

3.

Measure  whether  the  energy-saving  lamp  saves  energy  or  not,  and  how 

much energy it save in the end:   

Choose  the  Power  Measurement  function,  you  can  observe  the  luminance  of  the 

energy-saving lamp, and measure the lamp’s real power consumption. Then, comparing 

to other lamps with the same power, you can clearly know the energy-economizing effect 

of the energy-saving lamp. 

 

4

Measure the power consumption on electrical equipments:   

This product has functions of Power Measurement, kilowatt-hour measurement, etc; 

you  can choose  any  of  both to measure  power consumption  on  electrical equipments. 

Specially, it has 4 decimals to display kilowatt-hour, you can clearly and intuitively see 

power consumption on electrical equipments at per second, per minute, per hour. Further 

more,  you  can  also  easily  measure  detailed  power  consumption  of  these  electrical 

equipments in a period of time, through resetting time and power measurement to zero.   

 

 


background image

 

 

5

Clearly see the power consumption of electrical appliances:   

You are able to know exactly how much do your appliances (like rice cooker, induction 

cooker, electric heater) cost in a day or a month, when using them to do the cooking or 

boiling water. After that, you can see which one is the cheapest to use, comparing with 

gas.   

 

6

Clearly see how much you spend on your daily-used household appliances, 

like Microwave Ovens and Washing machines: 

Connect  the  ammeter  with  your  appliances;  reset  the  accumulated  power 

consumption to zero, and then turn on your appliances. When it finishes working, you can 

exactly read how much the consumption is, and then switch to see Electric power charge, 

you can see how much you need to pay for cooking or washing.   

 

7

Does TV still consume electricity in Standby Mode?   

Connect  the  TV  with  the  ammeter,  choose  Power  Measurement  function,  you  can 

clearly read its real power consumption when TV is in Standby Mode. This product can 

measure electrical equipments with power as low as 1 watt. (If the power of electrical 

equipment is 1 Watt, it has to keep on working 1 year to reach 1 KWH.)   

 

8

How  to  set  up  air-conditioner  in  a  good  operation  condition,  to  meet  the 

requirements of comfort and energy-saving? 

When  the  ambient  temperature,  humidity  and  other  things  are  changing,  the 

air-conditioner’s temperature or mode needs to be adjusted accordingly, to ensure the 

comfortable and energy-efficient environment. You can choose the Power Measurement 

function, or Kilowatt-Hour Measurement function or Operation Condition function, adjust 

the air-conditioner’s temperature to select different operation modes (such as cooling, 

dehumidificationventilator and so on). This can help find out real power consumption of 

air-conditioner  in  different  operation  modes.  Finally,  it  helps  you  find  the  appropriate 

operation  modes  under  different  weather  conditions,  which  also  meet  your  needs  of 

comfort and energy-saving. 

 

9.

 

Detect if the air conditioner or the refrigerator is under normal operation, if 

it is necessary to add refrigerant: 

Without special tools, it is very difficult for the laypeople to promptly find whether the 

air conditioner and the refrigerator are under normal operation. This ammeter can help 

you make it. Under normal operation, the operation power of air conditioner or 

refrigerator should be close to the power rating shown on the label. Based on this, you 

can use the Power Measurement function to detect the operation power, and then you can 

tell if your air conditioner or refrigerator is under normal operation or not, as well as if 

refrigerant is needed or not. If operation power is over greater (more than 20% greater) 

or over lower (more than 20% lower), operation of your air conditioner or refrigerator is 

abnormal. Over greater operation power indicates that the compressor or auxiliary fan 

relay is over loaded. Blockage may exist in the ventilation system or pipeline, and it needs 

cleaning; besides, there may be something wrong with the compressor or auxiliary fan 

 


background image

 

 

relay, needs repairing. Small problems often caused by short of refrigerant, this can be 

judged by the ratio of operation condition together with the cooling effect. Long-time 

operation with faults will largely increase power consumption and shorten the useful time 

of your air conditioner and refrigerator as well. 

Moreover, you can use the ratio of operation condition and the standby power to detect 

and judge if your air conditioner and refrigerator is under normal operation, like described 

in the operation manual (point 5 on page 8).   

As is known to everyone, according to rooms in different size and different 

environment conditions, you need to choose compatible air conditioners in different 

power. If you choose one with larger power than you need, it will increase power 

consumption and cause waste of power; if you choose one with lower power than you 

need, it is difficult to achieve comfortable temperature even the air conditioner works day 

to night. With compatible power, if environmental temperature is not too high, operation 

condition of the air conditioner is not abnormal, and the operating temperature is set up 

scientifically (that is set up by 5 to 7 degrees lower than environmental temperature.), 

the ratio of operation condition will not be larger than 50%. Similarly, if environmental 

temperature is not too high, refrigerating temperature is not set too low (that is to say it 

is suitable for refreshment of the vegetables and fruits.), and the refrigerator is under 

normal operation, the ratio of operation condition will not be larger than 30%.   

Set  up  the  ratio  of  operation  condition  and  the  standby  power  accordingly,  if  the 

ammeter gives out alarm, you should firstly check the following situations: if doors and 

windows are closed, if environmental temperature is much higher than before, or if the 

air-conditioner’s temperature is set too low. If not, there may be some faults existed or 

the  air-condition  needs  refrigerant.  The  same  as  refrigerator,  if  there  are  no  great 

changes on working environment, but the ammeter gives out alarm, there may be some 

faults  or  short  of  refrigerant.  At  this  very  moment,  please  check  the  real  power  and 

comparing it with the power rating, then you can clearly know if refrigerant is needed. 

Quick treatment is needed  while the  alarm  is  given  out;  Or  else, the  cooling  effect  of 

air-conditioner  or  refrigerator  will  become  worse  and  power  consumption  will  also 

increase.   

 

10.

 

Other applications: 

1)

 

How much should you pay for your air conditioner within one hour and within one 

night? How much should you pay for your refrigerator for one day?   

2)

 

Which takes more power consumption? The host of computer or the monitor? How 

much is the power consumption while all the computer equipment are under working? 

3)

 

How much does it cost for charging the mobile phone battery once? 

4)

 

How much is the power consumption for charging the electric motor car once? How 

much does it cost to drive one kilometer? 

5)

 

While  living  in  shared  accommodation,  how  to  tell  the  power  consumption  of 

respective appliance? 

6)

 

This ammeter can be used as a timer. 

7)

 

This ammeter can be used as a socket adapter for kinds of electric plugs (two pins, 

three pins, square pins, round pins, flat pins). 

 


background image

 

 

8)

 

... 

Just imagine, you can find many more applications of this ammeter. 

 

 

Note 

 

      ·This product is protected by the Chinese Patent (Patent No. ZL2006200165630). 

Introductions and explanations of the product’s characteristics and functions as well as 

other information are all the latest effective information; and all information are printed 

accurately.  The  Company  retains  the  right  of  correcting  the  direction  and  the  right  of 

changing any information or explanation, and the power of prior notice does not bear any 

responsibility. 

      ·The  company  owns  all  software  copyright  of  this  product  possibly  including  the 

software stored in the semiconductor memory or other chips. Therefore, within the limits 

prescribed  by  law,  any  individual  is  not  allowed  to  amend,  anti-design,  market  or 

reproduce the software owned by the company in any way. 

·This product will not result in harmful interference, and is able to bear interference, 

including the interference which may lead to erroneous operation.   

        ·This product should not be used for a long time with appliance over 2000W. If need 

to measure appliance over 2000 W, exact working time can be judged by touching the 

product’s shell; if it is overheating, please cut down the power supply connection of the 

appliance and this ammeter.   

        ·Measurement  data  is  only  for  reference.  If  problem  occurs,  please  go  to  the 

designated repair and maintenance service shop for professional repair, or contact with 

the supplier; voluntary dismantlement is not allowed since it may bring damage to the 

product and cause danger. 

·Quality guarantee period is 1 year. 

 

      Scientific use, clearly consumption, power saving guardian save electricity 